Abstract

Background: Biomechanics of an implant-supported prosthesis play a key role in the success or failure of rehabilitation of missing teeth. This study aimed to analyze biomechanical factors, such as an implant design and prosthesis design for a single implant-supported prosthesis. An in-vitro strain gauge analysis and finite element analysis were performed to assess different implant thread shapes and prosthesis retention modes for their strain-producing property in the peri-implant region of bone. Methodology: Four study models were prepared. Two models were fitted with Bio Horizon Tapered-Pro implants having predominant buttress-shaped threads (BT) and then two models were fitted with Grande Morse Neo Dent implants having trapezoid-shaped threads (TT). Each design was used with two types of retention modes for prostheses, BP-C and TT-C for cement-retained prostheses and similarly BT-S and TT-S for screw-retained prostheses. The strain gauges were bonded to the models and connected to a strain meter. Using an opposing porcelain fused to a metal prosthesis, a combined (axial and non-axial) load of 50–300 N at a strain rate of 0.95 mm/s was applied stepwise to each prosthesis. The strain values were recorded, and the collected data were organized and analyzed using SPSS version 22. For the finite element analysis, four 3-D models were designed. The bone, dental implants, and prostheses for each group were designed using Solid Works. A static, linear simulation was conducted in Ansys software. Results and discussion: The strain values recorded were all less than 3000μɛ and within the physiological loading zone as per Frost’s theory. Statistically significant differences were found between all groups with p-values <0.05, suggesting that changes in implant design led to differences in peri-implant bone strains. At the maximum loading of 300 N, i.e., at the mean biting force of an individual adult, the maximum strain value of 1812 με was recorded for group TT-C. At the minimum loading, all strain values were less than 500 με except for group TT-C for which 518 με was recorded. The peri-implant bone next to the implant’s crest showed maximum strain, which means that this site is more subjected to the effects of overloading than any other part. The von Mises stress was seen concentrated at the implant neck. Conclusion: TT-C implant-supported prostheses give a high strain profile. In comparison, the BT-C implant-supported prostheses give a low strain profile at mean biting forces.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Dental Materials, Army Medical College National University of Medical Sciences 1 , Islamabad, Pakistan

Department of Clinical Sciences, College of Dentistry, Ajman University 2 , Ajman, United Arab Emirates

Center of Medical and Bio-allied Health Sciences Research, Ajman University 3 , Ajman, United Arab Emirates

References (45)

Show source-provided references
1. Success criteria in implant dentistry: A systematic review10.1177/0022034511431252 ↗
2. Factors associated with early and late failure of dental implants10.1111/j.2041-1626.2012.00162.x ↗
3. Implant failure: A dentist’s nightmare10.4103/0974-6781.202154 ↗
4. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years10.1111/j.1600-0501.2012.02547.x ↗
5. Survival and success of single-tooth dental implant: A retrospective evaluation
6. Potential risk factors for early and late dental implant failure: A retrospective clinical study on 9080 implants10.1186/s40729-020-00276-w ↗
7. Factors affecting the survival rate of dental implants: A retrospective study10.4103/jispcd.jispcd_380_17 ↗
8. Biomechanical overloading factors influencing the failure of dental implants: A review
9. Implant failure: Etiology and complications10.4317/medoral.16.e42 ↗
10. Failure analysis in a dental implant10.1016/j.engfailanal.2015.07.035 ↗
11. The influence of functional forces on the biomechanics of implant-supported prostheses—A review10.1016/s0300-5712(02)00065-9 ↗
12. Biomechanics studies in dentistry: Bioengineering applied in oral implantology10.1097/scs.0b013e3181acdb81 ↗
13. Finite element analysis: A boon to dentistry10.1016/j.jobcr.2014.11.008 ↗
14. Mechanical aspects of dental implants and osseointegration: A narrative review10.1016/j.jmbbm.2019.103574 ↗
15. Power screws
16. A comparison between screw- and cement-retained implant prostheses. A literature review10.1563/aaid-joi-d-10-00146 ↗
17. Factors affecting the decision to use cemented or screw-retained fixed implant-supported prostheses: A critical review10.11607/ijp.5279 ↗
18. Influence of different restorative materials on the stress distribution in dental implants10.4317/jced.54554 ↗
19. Approach of dental practitioners towards the selection of implant designs; a cross-sectional study
20. Analysis of bone stress and primary stability of a dental implant using strain and torque measurements10.1016/j.sdentj.2023.01.006 ↗
21. Strain sensitivity as selection criterion for elastic elements of force transducers: A brief review10.1016/j.sna.2020.112238 ↗
22. Three-dimensional finite element investigation into effects of implant thread design and loading rate on stress distribution in dental implants and anisotropic bone10.3390/ma14226974 ↗
23. Biomaterials and clinical application of dental implants in relation to bone density—A narrative review10.3390/jcm12216924 ↗
24. What is the best micro and macro dental implant topography?10.1016/j.cden.2019.02.010 ↗
25. Effect on osseointegration of two implant macro-designs: A histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit’s tibiae10.4317/medoral.22825 ↗
26. The effect of implant macro-thread design on implant stability in the early post-operative period: A randomized, controlled pilot study10.1111/clr.12945 ↗
27. Finite element analysis of dental implant prosthetics10.1016/j.matpr.2017.10.134 ↗
28. Three-dimensional image correlation analyses for strains generated by cement and screw-retained implant prostheses10.1111/j.1708-8208.2011.00411.x ↗
29. Effects of screw- and cement-retained implant-supported prostheses on bone: A nonlinear 3-D finite element analysis10.1097/id.0000000000000278 ↗
30. In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorations10.1016/j.prosdent.2007.01.001 ↗
31. Effect of different impactor designs on biomechanical behavior in the interface bone-implant: A comparative biomechanics study10.1016/j.cmpb.2020.105723 ↗
32. Stress distribution of single-implant–retained overdenture reinforced with a framework: A finite element analysis study10.1016/j.prosdent.2017.07.016 ↗
33. The prosthetic influence and biomechanics on peri-implant strain: A systematic literature review of finite element studies10.5037/jomr.2016.7304 ↗
34. The effect of offset implant configuration on bone stress distribution: A systematic review10.1111/jopr.12221 ↗
35. Finite element analysis of a new dental implant design optimized for the desirable stress distribution in the surrounding bone region10.3390/prosthesis2030019 ↗
36. Numerical analysis of the mechanical stimuli transferred from a dental implant to the bone10.22061/jcarme.2021.7542.2001 ↗
37. Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading10.1034/j.1600-0501.2001.120614.x ↗
38. Influence of orthotropy on biomechanics of peri-implant bone in complete mandible model with full dentition10.1155/2014/709398 ↗
39. Finite element analysis in implant dentistry: State of the art and future directions10.1016/j.dental.2023.04.002 ↗
40. Finite with infinite possibilities”- “A boon to implant dentistry” - A brief overview on finite element analysis10.36106/paripex ↗
41. Finite element analysis and its applications in dentistry
42. Practical aspects of finite element method applications in dentistry10.1515/bjdm-2017-0011 ↗
43. Biomechanical models: Key considerations in study design10.1097/oi9.0000000000000099 ↗
44. Extracting accurate strain measurements in bone mechanics: A critical review of current methods10.1016/j.jmbbm.2015.06.006 ↗
45. Peri-implant bone resorption risk of anterior maxilla narrow single implants: A finite-element analysis10.1080/26415275.2022.2135516 ↗