Heat transfer of copper mesh–powder composite-based sintered-wick vapor chamber
Source abstract
Abstract
With the rapid spread of high-power density equipment, the vapor chamber must adapt to more applicable environments and exhibit a better heat transfer performance. The copper mesh and powder are sintered in this work to make a composite wick vapor chamber (CW-VC). Six sections of copper wire are cut and sintered together with the wick as the inner support column of the CW-VC. The effects of filling ratio and inclination on the heat transfer performance of the vapor chamber are investigated. The experimental results showed that the maximum thermal power of the CW-VC is 23.29 W at the optimal liquid filling ratio of 80% and the lowest thermal resistance is 0.33 °C/W. Below the liquid filling ratio of 60%, when the inclination angle of the CW-VC increases, its thermal resistance increases. At filling ratios of 70%, 80%, and 90%, the inclination angle of 30° can reduce the thermal resistance of the CW-VC. It implies that the inclination angle of the CW-VC can be increased appropriately to reduce the thermal resistance when the filling ratio is high. However, when the liquid filling ratio is low, increasing the inclination angle of the CW-VC will make the liquid film of the evaporator thinner and dry out earlier and its thermal resistance will increase.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Heat Transfer and Boiling Studies · Heat Transfer and Optimization · Refrigeration and Air Conditioning Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Information Engineering and Automation, Kunming University of Science and Technology 1 , Kunming 650500, China
Yunnan Key Laboratory of Green Energy, Electric Power Measurement Digitalization, Control and Protection 2 , Kunming 650500, China
Yunnan Institute of Measuring and Testing Technology 3 , Kunming 650228, China
Funding
National Science Foundation of China
References (30)
Show source-provided references
1. Wick-free paradigm for high-performance vapor-chamber heat spreaders10.1016/j.enconman.2021.115138 ↗
2. Powder sintered flat micro-heat pipe with wettability modification10.1142/s0217979222400094 ↗
3. Shape optimization of composite porous vapor chamber with radial grooves: A study on the minimization of maximum pressure drop10.1016/j.applthermaleng.2021.117735 ↗
4. Optimization of the coupling groove parameters of composite porous vapor chamber10.1016/j.applthermaleng.2021.118007 ↗
5. Fill ratio effects on vapor chamber thermal resistance with different configuration structures10.1016/j.ijheatmasstransfer.2018.07.029 ↗
6. Experimental investigation of vapor chambers with different wick structures at various parameters10.1016/j.expthermflusci.2016.04.017 ↗
7. Fabrication and characterization of pure-metal-based submillimeter-thick flexible flat heat pipe with innovative wick structures10.1016/j.ijheatmasstransfer.2018.01.135 ↗
8. Experimental thermal performance characterization of flat grooved heat pipes10.1080/01457632.2018.1442395 ↗
9. Thermal transfer characteristics of flat plate micro heat pipe with copper spiral woven mesh and a copper foam composite wick10.3390/nano11112821 ↗
10. Experimental study of flat plate micro heat pipe with multi-layer structured wick10.1142/s0217979222500692 ↗
11. Experimental investigation on the thermal performance of three-dimensional vapor chamber for LED automotive headlamps10.1016/j.applthermaleng.2019.03.049 ↗
12. On the thermal performance of the vapor chamber with micro-channel for unmixed air flow cooling10.4186/ej.2015.19.1.125 ↗
13. Thermal performance enhancement of an ultra-thin flattened heat pipe with multiple wick structure10.1016/j.applthermaleng.2020.116203 ↗
14. A new approach to thin film evaporation modeling10.1016/j.ijheatmasstransfer.2016.05.091 ↗
15. Effect of design and operating parameters on the thermal performance of aluminum flat grooved heat pipes10.1016/j.applthermaleng.2017.12.085 ↗
16. Development and thermal performance of a vapor chamber with multi-artery reentrant microchannels for high-power LED10.1016/j.applthermaleng.2019.114686 ↗
17. Significant factors affecting heat transfer performance of vapor chamber and strategies to promote it: A critical review10.1016/j.ijheatmasstransfer.2021.121132 ↗
18. Performance gravity-assisted heat pipes operated at small tilt angles
19. Comparative study of heat pipes performances in different orientations
20. Effect of inclination angle on the performance of a kind of vapor chamber10.1186/s40539-014-0012-7 ↗
21. Analysis of heat transfer performance and vapor–liquid meniscus shape of ultra-thin vapor chamber with supporting columns10.1016/j.applthermaleng.2021.117001 ↗
22. Thermal performance evaluation of thin vapor chamber10.1016/j.applthermaleng.2018.12.034 ↗
23. An integrated heat pipe coupling the vapor chamber and two cylindrical heat pipes with high anti-gravity thermal performance10.1016/j.applthermaleng.2019.113816 ↗
24. Research and optimization design of limited internal cavity of ultra-thin vapor chamber10.1016/j.ijheatmasstransfer.2019.119101 ↗
25. Investigations of biporous wick structure dryout10.1115/1.4005099 ↗
26. Thermal performance of loop heat pipe with porous copper fiber sintered sheet as wick structure10.1016/j.applthermaleng.2016.07.121 ↗
27. Vapor chamber with two-layer liquid supply evaporator wick for high-heat-flux devices10.1016/j.applthermaleng.2021.116803 ↗
28. Experimental investigation of a novel asymmetric heat spreader with nanostructure surfaces10.1016/j.expthermflusci.2013.09.011 ↗
29. Experimental study on capillary and mechanical properties of a porous nickel–copper composite10.1080/02670836.2019.1630084 ↗
30. Fabrication and experimental investigation of the bionic vapor chamber10.1016/j.applthermaleng.2019.114889 ↗