journal article·2018-07-01Open access

Field-frequency lock approach for 21.3-MHz high-performance NMR relaxation analyzer

Shanshan Chen, Luoyuan Xu, Hongzhi Wang, Shuguang Dai

AIP Advances· Volume 8· Issue 7

Abstract

Low-field NMR (LF-NMR) relaxation analyzers have been more and more widely used in food science, biomedicine, and petroleum exploration in recent years. An LF-NMR device analyzes various interactions between sample molecules through spin relaxation, diffusion, flow, and imaging experiments. However, temporal field fluctuations in the magnet limit the scope of application. A stable magnetic field is the basic guarantee for detecting weak signals with shorter relaxation time. This paper presents an approach involving a field-frequency lock for a 21.3-MHz high-performance NMR bipolar permanent magnet. The diameter spherical volume (DSV) of the magnet is only 60 mm. The field-frequency lock system uses 19F in a micro coil integrated into the main probe as a lock detector. The required magnetic field compensation can be calculated from the lock free induction decay (FID) signal frequency, which is measured by lock spectroscopy. The compensation coils used to produce the magnetic field were designed based on Helmholtz coils. The system determines the signal frequency by detecting the lock FID signal and calculates the required compensation-coil current to stabilize the main magnetic field of the analyzer. The results of practical locking experiments in a 21.3-MHz high-performance NMR relaxation analyzer showed that this new approach helps to reduce magnetic field fluctuations from 11 ppm/3h (11 × 10–6) to 0.4 ppm/3h (0.4 × 10–6), which meets the application requirements. This approach is especially viable and effective for a permanent magnet with large field fluctuations. This paper also provides observations of the effect of these fluctuations on NMR measurements before and after installation of the field-frequency lock system.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: NMR spectroscopy and applications · Advanced MRI Techniques and Applications · Advanced NMR Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology 1 , Shanghai 200-093, China

Medical Imaging College, Shanghai University of Medicine & Health Science 2 , Shanghai 201-318, China

SuzhouNiumag Corporation, Ltd. 3 , Shuzhou 215-163, China

Shanghai Key Laboratory of Magnetic Resonance, East China Normal University 4 , Shanghai 200-062, China

Funding

national major scientific instruments development project

References (16)

Show source-provided references
1. Prog. Nucl. Magn. Reson. Spectrosc. · 2014 · 76 · 110.1016/j.pnmrs.2013.09.001 ↗
2. J. Magn. Reson. · 2013 · 229 · 1210.1016/j.jmr.2012.11.010 ↗
3. Rev. Sci. Instrum. · 1989 · 60 · 296410.1063/1.1140636 ↗
4. J. Magn. Reson. · 2002 · 159 · 19010.1016/s1090-7807(02)00012-5 ↗
5. J. Magn. Reson. · 2007 · 184 · 25810.1016/j.jmr.2006.10.010 ↗
6. J. Magn. Reson. · 2008 · 191 · 12810.1016/j.jmr.2007.12.009 ↗
7. Phys. Rev. Lett. · 2000 · 85 · 373210.1103/physrevlett.85.3732 ↗
8. Chem. Phys. Lett. · 2007 · 442 · 47810.1016/j.cplett.2007.06.016 ↗
9. Rev. Sci. Instrum. · 1948 · 19 · 43510.1063/1.1741290 ↗
10. Rev. Sci. Instrum. · 1957 · 28 · 31310.1063/1.1715873 ↗
11. J. Magn. Reson. · 1978 · 30 · 35110.1016/0022-2364(78)90106-3 ↗
12. Revi. Sci. Instrum. · 1978 · 49 · 78510.1063/1.1135615 ↗
13. Rev. Sci. Instrum. · 2000 · 71 · 288210.1063/1.1150707 ↗
14. Rev. Sci. Instrum. · 2012 · 83 · 10511010.1063/1.4757576 ↗
15. J. Magn. Reson. · 2011 · 212 · 25410.1016/j.jmr.2011.05.010 ↗
16. Meas. Sci. Technol. · 2017 · 28 · 05590210.1088/1361-6501/aa61b1 ↗