S-shaped characteristics of pump turbine with large guide vane opening by experimental and numerical analysis
Source abstract
Abstract
Pumped storage hydropower is perhaps the most reliable solution to the energy crisis, but its development and application are limited by hydraulic instability, such as S-shaped characteristics. In this paper, based on the S-shaped region pressure fluctuation test of a model pump turbine, the connection between the guide vane opening and S-shaped pressure fluctuation is established, and a guide vane opening of 28 mm is selected for numerical analysis to expand the discussion of the S-shaped pressure fluctuation characteristics to large guide vane openings. The frequency components of the vaneless space are extracted by fast Fourier transform analysis, and the rotational stall frequency is identified. Among them, the blade passage frequency and its multiplier are induced by the rotor–stator interaction, and the low-frequency component of pressure fluctuations is induced by the rotational stall and vortex rope. Based on this, the internal flow and flow rate along the S-shaped characteristic curve and their correlation with the rotational stall are analyzed. In addition, the percentage of and variation in the entropy production rate in the S-shaped region are also analyzed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Cavitation Phenomena in Pumps · Hydraulic and Pneumatic Systems · Water Systems and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. Sustainable development of renewable energy integrated power sector: Trends, environmental impacts, and recent challenges10.1016/j.scitotenv.2022.153645 ↗
2. Capacity optimization of pumped storage hydropower and its impact on an integrated conventional hydropower plant operation10.1016/j.apenergy.2022.119561 ↗
3. Unstable operation of high-head reversible pump-turbines
4. Unstable behaviour of pump-turbines and its effects on power regulation capacity of pumped-hydro energy storage plants10.1016/j.rser.2018.06.018 ↗
5. S-shaped characteristics on the performance curves of pump-turbines in turbine mode—A review10.1016/j.rser.2015.12.312 ↗
6. Pressure fluctuations in vaneless space of pump-turbines with large blade lean runners in the S-shaped region10.1016/j.renene.2020.02.097 ↗
7. Unstable characteristics and rotating stall in turbine brake operation of pump-turbines10.1115/1.4003874 ↗
8. A review of rotating stall in reversible pump turbine10.1177/0954406216640579 ↗
9. Experimental evidence of rotating stall in a pump-turbine at off-design conditions in generating mode10.1115/1.4004088 ↗
10. Non-intrusive detection of rotating stall in pump-turbines10.1016/j.ymssp.2014.03.007 ↗
11. Pressure fluctuation and flow instability in S-shaped region of a reversible pump-turbine10.1016/j.renene.2020.03.069 ↗
12. Unstable S-shaped characteristics of a pump-turbine unit in a lab-scale model10.1016/j.renene.2021.03.013 ↗
13. Influence of guide vane opening on water-ring flow characteristics of pump-turbine in synchronous condenser mode
14. Experimental investigation of hysteresis on pump performance characteristics of a model pump-turbine with different guide vane openings10.1016/j.renene.2019.12.065 ↗
15. S-Shape region pressure pulsation measurement of model reversible pump-turbine
16. Research on internal flow characteristics of pump-turbine in turbine plate under different guide vane openings
17. Pressure pulsation model test investigation of pump-turbine on the turbine-brake condition,” Large Electr. Mach. Hydraul. Turbine · 2016 · 03 · 41
18. Flow instability transferability characteristics within a reversible pump turbine (RPT) under large guide vane opening (GVO)10.1016/j.renene.2021.07.039 ↗
19. Suppression of cavitation in the draft tube of Francis turbine model by J-Groove10.1177/0954406218802310 ↗
20. Optimal design of J-groove shape on the suppression of unsteady flow in the Francis turbine draft tube10.1007/s12206-019-0423-x ↗