The effect of surface contamination of tiny satellite on DC probe ionosphere measurement
Source abstract
Abstract
The DC Langmuir probe is a widely-used instrument for the plasma measurement in the space missions. But to apply DC Langmuir probe to a tiny satellite, such as a cubesat, for ionosphere study is difficult to get accurate electron density (ne) and electron temperature (Te) for two reasons: the contamination on both satellite surface and the electrode to be used, and a lack of conductive surface area of the tiny satellite. Under the charging effect of the satellite with an insufficient area ratio between the surface of the probe and the spacecraft, the contaminations on the surface of both probe and the satellite, acting as equivalent capacitances and resistances, modify both the potentials on the satellite and the probe, and an elevated Te and a suppressed ne are derived incorrectly. In this paper, the effect of the surface contamination on the DC Langmuir probe measurements onboard a tiny satellite is investigated in detail. The effects of the accumulated charge and the impedances on the contamination layers have been identified in the experiments done in a ground chamber with similar plasma conditions in the Earth’s ionosphere, and the characteristic dependences of the probe sweeping frequency and the plasma density are presented. The experiment result suggests that a contamination-free instrument TeNeP, operated at 0.2∼10 MHz probe sweeping frequency and sweeping potentials below 500 mV, is a better solution to obtain accurate Te and ne, onboard a satellite with a surface area ratio below 100.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ionosphere and magnetosphere dynamics · Plasma Diagnostics and Applications · Magnetic Field Sensors Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Space and Plasma Sciences, National Cheng Kung University 1 , Tainan, Taiwan , 70101
International Center for Space Weather Study and Education, Kyushu University 2 , Fukuoka, Japan , 819-0395
Asia Space Environment Research Consortium Co. Ltd. 3 , Tokyo, Japan , 182-0024
Funding
Ministry of Science and Technology, Taiwan
References (21)
Show source-provided references
1. Self-cleaning Langmuir probe10.1063/1.1144074 ↗
2. Contamination-free sounding rocket Langmuir probe10.1063/1.1357234 ↗
3. Langmuir probe measurements in the ionosphere
4. Langmuir probe measurements in the ionosphere
5. Plasma measurements in the space plasma operation chamber (SPOC)
6. Back-diffusion plasma generator for ionosphere study10.1088/1361-6595/aa92fc ↗
7. A floating double probe method for measurements in gas discharges10.1103/physrev.80.58 ↗
8. A critical overview on spacecraft charging mitigation methods10.1109/tps.2003.820969 ↗
9. The theory of collectors in gaseous discharges10.1103/physrev.28.727 ↗
10. The pulsed Langmuir probe technique to mitigate contamination effects on small spacecraft
11. Understanding Langmuir probe current-voltage characteristics10.1119/1.2772282 ↗
12. Observation of low latitude ionosphere by the impedance probe on board the Hinotori satellite10.5636/jgg.38.111 ↗
13. Application of a glass-sealed Langmuir probe to ionosphere study10.1063/1.1134476 ↗
14. Electron temperature probe on board Japan’s 9th scientific satellite ‘OHZORA10.5636/jgg.37.413 ↗
15. Means to remove electrode contamination effect of Langmuir probe measurement in space10.1063/1.4722167 ↗
16. Electron temperature and density probe for small aeronomy satellites10.1063/1.4927342 ↗
17. Use of a Langmuir probe instrument on board a pico-satellite10.1109/tps.2017.2700211 ↗
18. Dynamic probe measurements in the ionosphere
19. Area influences and floating potentials in Langmuir probe measurements10.1063/1.1661297 ↗
20. Effect of finite electrode area ratio on high-frequency Langmuir probe measurements10.1088/0022-3727/45/7/075205 ↗
21. How big is a small Langmuir probe?10.1063/1.874162 ↗