journal article·2016-07-01Open access

Calculation of an optimized design of magnetic shields with integrated demagnetization coils

Z. Sun, A. Schnabel, M. Burghoff, L. Li

AIP Advances· Volume 6· Issue 7

Abstract

Magnetic shielding made from permalloy is frequently used to provide a time-stable magnetic field environment. A low magnetic field and low field gradients inside the shield can be obtained by using demagnetization coils through the walls, encircling edges of the shield. We first introduce and test the computational models to calculate magnetic properties of large size shields with thin shielding walls. We then vary the size, location and shape of the openings for the demagnetization coils at the corners of a cubic shield. It turns out that the effect on the shielding factor and the expected influence on the residual magnetic field homogeneity in the vicinity of the center of the shield is negligible. Thus, a low-cost version for the openings can be chosen and their size could be enlarged to allow for additional cables and easier handling. A construction of a shield with beveled edges and open corners turned out to substantially improve the shielding factor.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Atomic and Subatomic Physics Research · Magnetic Properties of Alloys · Geomagnetism and Paleomagnetism Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Harbin Institute of Technology 1 School of Electrical Engineering and Automation, , Harbin 150001, P.R. China

Physikalisch-Technische Bundesanstalt Berlin 2 , Berlin 10587, Germany

Funding

Deutsche Forschungsgemeinschaft · National Natural Science Foundation of China

References (10)

Show source-provided references
1. A magnetically shielded room with ultra low residual field and gradient10.1063/1.4886146 ↗
2. A large-scale magnetic shield with 106 damping at millihertz frequencies10.1063/1.4919366 ↗
3. Revised experimental upper limit on the electric dipole moment of the neutron10.1103/PhysRevD.92.092003 ↗
4. Demagnetization of magnetically shielded rooms10.1063/1.2713433 ↗
5. Dynamic modeling of the behavior of permalloy for magnetic shielding10.1063/1.4949516 ↗
6. Systematic design of magnetic shields10.1016/0304-8853(91)90682-Z ↗
7. Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer10.1063/1.1653195 ↗
8. Evaluation of a high-performance magnetically shielded room for biomagnetic measurement10.1109/20.545761 ↗
9. Nuclear magnetic resonance in the nanoTesla range10.1063/1.2006981 ↗
10. Design, construction, and performance of a large-volume magnetic shield10.1109/TMAG.1982.1061780 ↗