journal article·2020-12-01Open access

A lateral flow immunoassay with self-sufficient microfluidic system for enhanced detection of thyroid-stimulating hormone

Santosh Kumar Bikkarolla, Sara E. McNamee, Stuart McGregor, Paul Vance, Helen McGhee, Emma L. Marlow, James McLaughlin

AIP Advances· Volume 10· Issue 12

Abstract

We report a self-sufficient microfluidic paper-based lateral flow immunoassay device (μLFD) for highly sensitive detection of the thyroid-stimulating hormone (TSH). Fabrication of the paper microchannels involves engraving the nitrocellulose membrane with a CO2 laser to create narrow flow paths, which constrain the fluid flow over the test zone. The proposed microchannel modified devices were studied for detection of the TSH using gold nanoparticles as labels. The effect of such microchannel modified LFDs has led to an improvement in sensitivity by nine times and the limit of detection by 6.6 times due to the slow flow rate of the sample compared with the traditional LFD. In addition, the binding of gold nanoparticles over the test line is more uniform in the case of the μLFD, thus minimizing leading-edge effects, resulting in more accurate quantitative analysis. The proposed strategy offers great potential for multiplex detection of biomarkers with increased sensitivity without introducing any hydrophobic materials to the LFD.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Biosensors and Analytical Detection · Advanced biosensing and bioanalysis techniques · Advanced Biosensing Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Engineering, Engineering Research Institute, University of Ulster 1 , Newtownabbey BT37 0QB, United Kingdom

Randox Laboratories Ltd. 2 , 55 Diamond Road, Crumlin, County Antrim BT29 4QY, United Kingdom

Funding

Randox Laboratories

References (45)

Show source-provided references
1. J. Immunol. Methods · 2012 · 375 · 26410.1016/j.jim.2011.11.003 ↗
2. J. Immunol. Methods · 2008 · 336 · 910.1016/j.jim.2008.03.005 ↗
3. Biosci., Biotechnol., Biochem. · 2017 · 81 · 187410.1080/09168451.2017.1365590 ↗
4. Talanta · 2017 · 165 · 16710.1016/j.talanta.2016.12.042 ↗
5. Biosens. Bioelectron. · 2015 · 66 · 16910.1016/j.bios.2014.11.017 ↗
6. Anal. Biochem. · 2012 · 428 · 3110.1016/j.ab.2012.06.005 ↗
7. Biosensors · 2012 · 2 · 3210.3390/bios2010032 ↗
8. Analyst · 2014 · 139 · 145610.1039/c3an02296j ↗
9. Biomicrofluidics · 2018 · 12 · 03410410.1063/1.5035113 ↗
10. Lab Chip · 2015 · 15 · 163810.1039/c5lc00055f ↗
11. ACS Nano · 2018 · 12 · 27910.1021/acsnano.7b06229 ↗
12. Nano Lett. · 2017 · 17 · 557210.1021/acs.nanolett.7b02385 ↗
13. J. Mater. Chem. B · 2018 · 6 · 710210.1039/c8tb01603h ↗
14. Lab Chip · 2016 · 16 · 317710.1039/c6lc00712k ↗
15. Lab Chip · 2007 · 7 · 4110.1039/b611455e ↗
16. Bioanalysis · 2014 · 6 · 8910.4155/bio.13.296 ↗
17. Lab Chip · 2015 · 15 · 146510.1039/c4lc01127a ↗
18. Lab Chip · 2010 · 10 · 315710.1039/c0lc00132e ↗
19. Lab Chip · 2014 · 14 · 440610.1039/c4lc00972j ↗
20. Anal. Chem. · 2016 · 88 · 625410.1021/acs.analchem.6b00195 ↗
21. Crit. Rev. Biotechnol. · 2017 · 37 · 41110.3109/07388551.2016.1164664 ↗
22. Adv. Healthcare Mater. · 2017 · 6 · 160092010.1002/adhm.201600920 ↗
23. Biosens. Bioelectron. · 2018 · 113 · 9510.1016/j.bios.2018.05.001 ↗
24. Biomicrofluidics · 2015 · 9 · 02650310.1063/1.4919629 ↗
25. Lab Chip · 2013 · 13 · 38610.1039/c2lc41144j ↗
26. J. Chromatogr. B · 2019 · 1110-1111 · 110.1016/j.jchromb.2019.01.019 ↗
27. Analyst · 2013 · 138 · 67110.1039/c2an36219h ↗
28. 24 2010
29. Biomicrofluidics · 2020 · 14 · 01410710.1063/1.5131751 ↗
30. Micromachines · 2018 · 9 · 22010.3390/mi9050220 ↗
31. Rev. Endocr. Metab. Disord. · 2008 · 9 · 23710.1007/s11154-008-9094-0 ↗
32. Nat. Med. · 2004 · 10 · 63810.1038/nm1051 ↗
33. ACS Chem. Biol. · 2007 · 2 · 37710.1021/cb700104v ↗
34. Thyroid · 2008 · 18 · 23910.1089/thy.2007.0248 ↗
35. Biosens. Bioelectron. · 2015 · 71 · 16410.1016/j.bios.2015.04.022 ↗
36. Sens. Actuators, B · 2017 · 240 · 35810.1016/j.snb.2016.08.178 ↗
37. Biosens. Bioelectron. · 2013 · 40 · 18010.1016/j.bios.2012.07.014 ↗
38. J. Clin. Endocrinol. Metab. · 2001 · 86 · 458510.1210/jcem.86.10.7959 ↗
39. Biosens. Bioelectron. · 2018 · 110 · 9710.1016/j.bios.2018.03.003 ↗
40. Biosensors · 2018 · 8 · 9710.3390/bios8040097 ↗
41. Emerging Microbes Infect. · 2019 · 8 · 117810.1080/22221751.2019.1635430 ↗
42. See http://www.webcitation.org/76RrP6Swk for information on conjugation of antibodies to carboxyl coated gold nanoparticles by using EDC chemistry; accessed 27 March 2019.
43. Sens. Bio-Sens. Res. · 2016 · 9 · 1710.1016/j.sbsr.2016.04.002 ↗
44. J. Immunoassay Immunochem. · 2017 · 38 · 35510.1080/15321819.2016.1269338 ↗
45. Lab Chip · 2015 · 15 · 65510.1039/c4lc01239a ↗