Towards quantitative magnetic particle imaging: A comparison with magnetic particle spectroscopy
Source abstract
Abstract
Magnetic Particle Imaging (MPI) is a quantitative imaging modality with promising features for several biomedical applications. Here, we study quantitatively the raw data obtained during MPI measurements. We present a method for the calibration of the MPI scanner output using measurements from a magnetic particle spectrometer (MPS) to yield data in units of magnetic moments. The calibration technique is validated in a simplified MPI mode with a 1D excitation field. Using the calibrated results from MPS and MPI, we determine and compare the detection limits for each system. The detection limits were found to be 5·10-12 Am2 for MPS and 3.6·10-10 Am2 for MPI. Finally, the quantitative information contained in a standard MPI measurement with a 3D excitation is analyzed and compared to the previous results, showing a decrease in signal amplitudes of the odd harmonics related to the case of 1D excitation. We propose physical explanations for all acquired results; and discuss the possible benefits for the improvement of MPI technology.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Geomagnetism and Paleomagnetism Studies · Microfluidic and Bio-sensing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Physikalisch-Technische Bundesanstalt , Abbestrasse 2-12, 10587 Berlin, Germany
Funding
Deutsche Forschungsgemeinschaft · European Commission
References (13)
Show source-provided references
1. Tomographic imaging using the nonlinear response of magnetic particles10.1038/nature03808 ↗
2. Three-dimensional real-time in vivo magnetic particle imaging10.1088/0031-9155/54/5/l01 ↗
3. Weighted iterative reconstruction for magnetic particle imaging10.1088/0031-9155/55/6/003 ↗
4. Multidimensional X-space magnetic particle imaging10.1109/tmi.2011.2125982 ↗
5. Fast reconstruction in magnetic particle imaging,10.1088/0031-9155/57/4/1113 ↗
6. Edge preserving and noise reducing reconstruction for magnetic particle imaging10.1109/TMI.2016.2593954 ↗
7. Iterative choices of regularization parameters in linear inverse problems10.1088/0266-5611/14/5/010 ↗
8. Signal encoding in magnetic particle imaging: Properties of the system function10.1186/1471-2342-9-4 ↗
9. Analysis of a {3-D} system function measured for magnetic particle imaging10.1109/tmi.2012.2188639 ↗
10. Ferucarbotran (Resovist): a new clinically approved RES-specific contrast agent for contrast-enhanced MRI of the liver: Properties, clinical development, and applications10.1007/s00330-002-1721-7 ↗
11. Characterizing a preclinical magnetic particle imaging system with separate pick-up coil
12. In vivo liver visualizations with magnetic particle imaging based on the calibration measurement approach10.1088/1361-6560/aa562d ↗
13. Concentration dependent MPI tracer performance,