Design of a high SNR electronic heart sound sensor based on a MEMS bionic hydrophone
Source abstract
Abstract
Since most of the contact conduction type of heart sound sensors don’t take into account the acoustic signal attenuation problem caused by the heart sound signal transmitting to a sensor whose filling materials’ impedance is different to human soft tissue, the signal-to-noise ratio (SNR) of the heart sound sensors is not very well. Human heart is immersed in blood. If the sensor’s core sensitive element can be immersed in fluid, the attenuation of heart sound signal may be decreased greatly. Inspired by the principle of hydroacoustic signal’s detection, this paper proposes the design of heart sound sensor based on the bionic vector hydrophone. Then theoretical analysis and finite element method (FEM) simulation about the sensor have been carried out. Combined sensitivity with resonant frequency, the optimum dimension of the sensor’s structure has been determined. The sensor’s micro-structure has been fabricated by using Micro-Electro-Mechanical System (MEMS) technology and coupling encapsulated by choosing a kind of medical coupling agent as the filling material. Finally, the performance of the proposed sensor is tested. The fact is that the proposed sensor can work well with either healthy people or patients with heart disease. The obtained data clearly show that: the SNR of the proposed heart sound sensor is superior to 3200-type of 3M Littmann 8.2 dB.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Phonocardiography and Auscultation Techniques · ECG Monitoring and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Dynamic Testing Technology, North University of China 1 , Taiyuan 030051, China
Dept. of Electronics, Xinzhou Teachers University 2 , Xinzhou 034000, China
References (22)
Show source-provided references
1. IEEE Trans. Biomed. Eng. · 2016 · 63 · 64710.1109/tbme.2015.2468180 ↗
2. World Journal of Cardiology · 2010 · 2 · 11810.4330/wjc.v2.i5.118 ↗
3. Cardiovascular Devices and Systems · 2016 · 4 · 110.1109/jtehm.2016.2609901 ↗
4. Sensors · 2014 · 14 · 1383010.3390/s140813830 ↗
5. Entropy · 2016 · 18 · 110.3390/e18080281 ↗
6. IEEE Sensors Journal · 2017 · 17 · 386110.1109/JSEN.2017.2694970 ↗
7. Biomed. Eng. Online. · 2015 · 14 · 28310.1186/s12938-015-0056-y ↗
8. 2017 · 2610
9. Critical Reviews in Biomedical Engineering · 2018 · 46 · 3310.1615/critrevbiomedeng.2018025112 ↗
10. Biomed. Eng. Online. · 2018 · 17 · 110.1186/s12938-018-0540-2 ↗
11. Measurement Science and Technology · 2015 · 26 · 11210.1088/0957-0233/26/9/095701 ↗
12. Sens. Rev. · 2015 · 35 · 30310.1108/sr-11-2014-0744 ↗
13. IETE Technical Review · 2016 · 33 · 1110.1080/02564602.2015.1065713 ↗
14. Appl. Phys. Lett. · 2014 · 105 · 21370210.1063/1.4902869 ↗
15. Review of Scientific Instruments · 2018 · 89 · 05500210.1063/1.5021526 ↗
16. AIP Advances · 2018 · 8 · 110.1063/1.5044673 ↗
17. Sensors · 2016 · 16 · 110.3390/s16111728 ↗
18. Micoelectronics Journal · 2007 · 38 · 102110.1016/j.mejo.2007.09.008 ↗
19. IEEE Transactions on Bio-Medical Engineering · 1992 · 39 · 73010.1109/10.142648 ↗
20. The American Journal of Physiology · 1980 · 238 · H60410.1152/ajpheart.1980.238.4.H604 ↗
21. Journal of Applied Physics · 2007 · 101 · 04490810.1063/1.2654274 ↗
22. Journal of Mechanics in Medicine and Biology · 2012 · 12 · 124010.1142/s0219519412400076 ↗