journal article·2017-10-01Open access

A microfluidic approach for hemoglobin detection in whole blood

Nikita Taparia, Kimsey C. Platten, Kristin B. Anderson, Nathan J. Sniadecki

AIP Advances· Volume 7· Issue 10

Abstract

Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Erythrocyte Function and Pathophysiology · Erythropoietin and Anemia Treatment · Iron Metabolism and Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Mechanical Engineering, University of Washington 1 , Seattle, WA 98105, USA

Bioengineering, University of Washington 2 , Seattle, WA 98105, USA

Institute for Stem Cell and Regenerative Medicine, University of Washington 3 , Seattle, WA 98105, USA

Funding

National Science Foundation · U.S. Department of Education

References (29)

Show source-provided references
1. Anaemia in low-income and middle-income countries10.1016/s0140-6736(10)62304-5 ↗
2. Worldwide prevalence of anaemia, WHO Vitamin and Mineral Nutrition Information System, 1993-200510.1017/s1368980008002401 ↗
3. Malaria-related anaemia10.1016/s0169-4758(00)01774-9 ↗
4. High rate of sickle cell anaemia in Sub-Saharan Africa underlines the need to screen all children with severe anaemia for the disease10.1111/apa.13040 ↗
5. Malaria, anaemia and under-nutrition: Three frequently co-existing conditions among preschool children in rural Rwanda
6. Characterisation of anaemia and associated factors among infants and pre-schoolers from rural India10.1017/s1368980015002050 ↗
7. Global, regional, and national trends in haemoglobin concentration and prevalence of total and severe anaemia in children and pregnant and non-pregnant women for 1995-2011: A systematic analysis of population-representative data10.1016/s2214-109x(13)70001-9 ↗
8. A systematic analysis of global anemia burden from 1990 to 201010.1182/blood-2013-06-508325 ↗
9. Anemia: A comprehensive global estimate10.1182/blood-2013-12-543405 ↗
10. Spectrophotometric studies II. Preparations from washed blood cells; nitric oxide hemoglobin and sulfhemoglobin
11. 2015
12. Lauryl sulphate haemoglobin: A non-hazardous substitute for HiCN in haemoglobinometry10.1111/j.1365-2257.1991.tb00283.x ↗
13. Utility of point-of-care haemoglobin measurement in the HemoCue-B haemoglobin for the initial diagnosis of anaemia10.1111/j.1365-2257.2005.00678.x ↗
14. Cost-effective and rapid blood analysis on a cell-phone10.1039/c3lc41408f ↗
15. Smartphone dongle for simultaneous measurement of hemoglobin concentration and detection of HIV antibodies10.1039/c5lc00609k ↗
16. Chromatography paper as a low-cost medium for accurate spectrophotometric assessment of blood hemoglobin concentration10.1039/c3lc40908b ↗
17. Simple paper-based test for measuring blood hemoglobin concentration in resource-limited settings10.1373/clinchem.2013.204701 ↗
18. Direct hemoglobin measurement on a centrifugal microfluidic platform for point-of-care diagnostics10.1016/j.sna.2006.01.031 ↗
19. Deformability based cell margination—A simple microfluidic design for malaria-infected erythrocyte separation10.1039/c003873c ↗
20. A microfluidic model for single-cell capillary obstruction by Plasmodium falciparum infected erythrocytes10.1073/pnas.2433968100 ↗
21. The global burden of anemia10.1016/j.hoc.2015.11.002 ↗
22. Diffusion-model of the optical absorbance of whole-blood10.1364/josaa.5.000813 ↗
23. Single scattering by red blood cells10.1364/ao.37.007410 ↗
24. Influence of shear rate on the optical properties of human blood in the spectral range 250 to 1100 nm10.1117/1.2799154 ↗
25. Hemoglobin and hematocrit
26. Statistical methods for assessing agreement between two methods of clinical measurement
27. Optical transmission and reflection by blood10.1109/tbme.1970.4502710 ↗
28. The Fahraeus effect10.1016/0026-2862(71)90002-1 ↗
29. Microfluidic approaches to malaria detection10.1016/j.actatropica.2003.11.009 ↗