A novel non-imaging optics based Raman spectroscopy device for transdermal blood analyte measurement
Source abstract
Abstract
Due to its high chemical specificity, Raman spectroscopy has been considered to be a promising technique for non-invasive disease diagnosis. However, during Raman excitation, less than one out of a million photons undergo spontaneous Raman scattering and such weakness in Raman scattered light often require highly efficient collection of Raman scattered light for the analysis of biological tissues. We present a novel non-imaging optics based portable Raman spectroscopy instrument designed for enhanced light collection. While the instrument was demonstrated on transdermal blood glucose measurement, it can also be used for detection of other clinically relevant blood analytes such as creatinine, urea and cholesterol, as well as other tissue diagnosis applications. For enhanced light collection, a non-imaging optical element called compound hyperbolic concentrator (CHC) converts the wide angular range of scattered photons (numerical aperture (NA) of 1.0) from the tissue into a limited range of angles accommodated by the acceptance angles of the collection system (e.g., an optical fiber with NA of 0.22). A CHC enables collimation of scattered light directions to within extremely narrow range of angles while also maintaining practical physical dimensions. Such a design allows for the development of a very efficient and compact spectroscopy system for analyzing highly scattering biological tissues. Using the CHC-based portable Raman instrument in a clinical research setting, we demonstrate successful transdermal blood glucose predictions in human subjects undergoing oral glucose tolerance tests.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Spectroscopy Techniques in Biomedical and Chemical Research · Spectroscopy and Chemometric Analyses · Bee Products Chemical Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Massachusetts Institute of Technology George R. Harrison Spectroscopy Laboratory, , 77 Massachusetts Ave 6-205, Cambridge, Massachusetts 02139, USA
Funding
National Institutes of Health
References (36)
Show source-provided references
1. Raman spectroscopy for non-invasive glucose measurements10.1117/1.1920212 ↗
2. Development of a fiber optic probe to measure NIR Raman spectra of cervical tissue in vivo10.1111/j.1751-1097.1998.tb09703.x ↗
3. Optical fiber probe for biomedical Raman spectroscopy10.1364/AO.43.000542 ↗
4. Compound parabolic concentrator probe for efficient light collection in spectroscopy of biological tissue10.1364/AO.35.000758 ↗
5. Fiber optic probes for biomedical optical spectroscopy10.1117/1.1528207 ↗
6. Nonimaging Optics
7. T. J. Brukilacchio, “LED illuminator with retro reflector,” (U.S. Patent 0053184A1, 2007).
8. Holographic notch filter for low-wavenumber Stokes and anti-Stokes Raman spectroscopy10.1366/0003702914335553 ↗
9. Principles and spectroscopic applications of volume holographic optics10.1021/ac00057a002 ↗
10. 1989
11. 2005
12. Narcus , “Bright electroless plating process producing two-layer nickel coatings on dielectric subtrates,” (U.S. Patent 4160049, 1979).
13. In vivo Raman spectral pathology of human atherosclerosis and vulnerable plaque10.1117/1.2190967 ↗
14. Diagnosing breast cancer by using Raman spectroscopy10.1073/pnas.0501390102 ↗
15. Bulk Raman analysis of pharmaceutical tablets10.1366/000370206779321463 ↗
16. Prospects for the diagnosis of breast cancer by noninvasive probing of calcifications using transmission Raman spectroscopy10.1117/1.2718934 ↗
17. Noninvasive Raman tomographic imaging of canine bone tissue10.1117/1.2904940 ↗
18. Comparison of glucose concentration in interstitial fluid, and capillary and venous blood during rapid changes in blood glucose levels10.1089/15209150152607132 ↗
19. Intrinsic Raman spectroscopy for quantitative biological spectroscopy Part I: theory and simulations10.1364/OE.16.012726 ↗
20. Intrinsic Raman spectroscopy for quantitative biological spectroscopy Part II: experimental applications10.1364/OE.16.012737 ↗
21. Turbidity-corrected Raman spectroscopy for blood analyte detection10.1021/ac8025509 ↗
22. A multimodal spectroscopy system for real-time disease diagnosis10.1063/1.3117832 ↗
23. Elimination of background in fiber-optic Raman measurements10.1366/0003702904087235 ↗
24. The use of Raman spectroscopy to provide an estimation of the gross biochemistry associated with urological pathologies10.1007/s00216-006-0937-9 ↗
25. Diagnostic potential of near-infrared Raman spectroscopy in the stomach: differentiating dysplasia from normal tissue10.1038/sj.bjc.6604176 ↗
26. Detection of morphological markers of vulnerable atherosclerotic plaque using multimodal spectroscopy10.1117/1.2187943 ↗
27. Diagnosis of human coronary atherosclerosis by morphology-based Raman spectroscopy10.1016/S1054-8807(01)00063-1 ↗
28. Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy10.1016/S1386-1425(96)01779-9 ↗
29. Winefordner · 2000
30. 2007
31. Multivariate Analysis
32. Chemometric analysis of multisensor arrays10.1016/0250-6874(86)80023-3 ↗
33. Support vector regression machines
34. Multivariate calibration with least-squares support vector machines10.1021/ac035522m ↗
35. Development of robust calibration models using support vector machines for spectroscopic monitoring of blood glucose10.1021/ac101754n ↗
36. Evaluating clinical accuracy of systems for self-monitoring of blood glucose10.2337/diacare.10.5.622 ↗