Propagation-based phase-contrast tomography for high-resolution lung imaging with laboratory sources
Source abstract
Abstract
We have performed high-resolution phase-contrast tomography on whole mice with a laboratory setup. Enabled by a high-brilliance liquid-metal-jet source, we show the feasibility of propagation-based phase contrast in local tomography even in the presence of strongly absorbing surrounding tissue as it is the case in small animal imaging of the lung. We demonstrate the technique by reconstructions of the mouse lung for two different fields of view, covering the whole organ, and a zoom to the local finer structure of terminal airways and alveoli. With a resolution of a few micrometers and the wide availability of the technique, studies of larger biological samples at the cellular level become possible.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced X-ray Imaging Techniques · Laser-Plasma Interactions and Diagnostics · Digital Holography and Microscopy
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
University of Göttingen 1 Institute for X-Ray Physics, , 37077 Göttingen, Germany
University Medical Center Göttingen 2 Institute of Diagnostic and Interventional Radiology, , 37075 Göttingen, Germany
Medical Center Göttingen 3 Department of Haematology and Medical Oncology, , 37075 Göttingen, Germany
Max-Planck-Institute of Experimental Medicine 4 Department of Molecular Biology of Neuronal Signals, , 37075 Göttingen, Germany
References (30)
Show source-provided references
1. Phys. Rev. Lett. · 1996 · 77 · 296110.1103/PhysRevLett.77.2961 ↗
2. Journal of Physics D: Applied Physics · 1996 · 29 · 13310.1088/0022-3727/29/1/023 ↗
3. Nature · 1995 · 373 · 59510.1038/373595a0s ↗
4. Phys. Med. Biol. · 2007 · 52 · 692310.1088/0031-9155/52/23/010 ↗
5. J. R. Soc. Interface · 2010 · 7 · 166510.1098/rsif.2010.0281 ↗
6. Nat. Phys. · 2006 · 2 · 25810.1038/nphys265 ↗
7. PLoS ONE · 2013 · 8 · e5843910.1371/journal.pone.0058439 ↗
8. Applied Physics Letters · 2013 · 103 · 09110510.1063/1.4819766 ↗
9. Appl. Phys. Lett. · 2013 · 103 · 24410510.1063/1.4848595 ↗
10. Opt. Express · 2013 · 21 · 3018310.1364/OE.21.030183 ↗
11. Phys. Rev. Lett. · 2015 · 114 · 04810310.1103/PhysRevLett.114.048103 ↗
12. Phys. Rev. Lett. · 1998 · 80 · 258610.1103/PhysRevLett.80.2586 ↗
13. Appl. Phys. Lett. · 2007 · 91 · 07410410.1063/1.2769760 ↗
14. Appl. Phys. Lett. · 2013 · 103 · 08370310.1063/1.4818737 ↗
15. Phys. Rev. Lett. · 2014 · 112 · 25390310.1103/PhysRevLett.112.253903 ↗
16. PNAS · 2012 · 109 · 1788010.1073/pnas.1206684109 ↗
17. Radiology · 2013 · 269 · 42710.1148/radiol.13122413 ↗
18. J. Appl. Physiol. · 2013 · 114 · 71610.1152/japplphysiol.00855.2012 ↗
19. D. Larsson, Small-Animal Imaging with Liquid-Metal-Jet X-ray Sources, Ph.D. thesis,KTH Royal institute of technology, 2015.
20. Medical Physics · 2013 · 40 · 02190910.1118/1.4788661 ↗
21. 2006
22. Proc. SPIE · 2014 · 9212 · 92120R10.1117/12.2060390 ↗
23. J. Opt. Soc. Am. · 1983 · 73 · 143410.1364/JOSA.73.001434 ↗
24. Opt. Express · 2013 · 21 · 222010.1364/OE.21.002220 ↗
25. J. Microsc. · 2002 · 206 · 3310.1046/j.1365-2818.2002.01010.x ↗
26. J. Opt. Soc. Am. A · 2009 · 26 · 89010.1364/JOSAA.26.000890 ↗
27. J. Synchrotron Rad. · 2015 · 22 · 14310.1107/S1600577514021730 ↗
28. Rev. Sci. Instrum. · 2008 · 79 · 01610210.1063/1.2833838 ↗
29. See supplementary material at http://dx.doi.org/10.1063/1.4943898 for measurements of the energetic spectrum.10.1063/1.4943898 ↗
30. Sci. Rep. · 2015 · 510.1038/srep09973 ↗