Source abstract
Abstract
Breast cancer is a medical condition characterized by the uncontrolled proliferation of cells in the breast tissue. Breast cancer can originate from various parts of the breast, and methods such as Breast ultrasound, Diagnostic mammogram, Breast magnetic resonance imaging, and Biopsy are currently used for its diagnosis. However, these methods have certain limitations, and their size can be a hindrance. To overcome this, low-power, flexible antennas can be designed for bio-communication between medical equipment and external instrumentation. Flexible and wearable antennas have advantages such as affordability, ease of fabrication, and high gain. In this article, a microstrip patch antenna operating at 2.45 GHz and made of polyamide material is designed using High Frequency Structure Simulator software. The simulation results show the patch antenna has a gain of 1, −14.81 dB return loss at 2.45 GHz based on |S11| ≤ −10 dB. The directive radiation pattern with axial ratio of 63.39 dB and voltage standing wave ratio ≤3. Furthermore, the hardware development of proposed antenna with polyamide substrate provides the resonance frequency nearing to simulation results as 2.318 GHz with return loss of −28.19 dB. Based on mathematical analysis, simulation and hardware results, the proposed antenna is a superior option for breast cancer detection.
Source: crossref · Quality: baseline
Affiliations
Department of Mechatronics Engineering, Thiagarajar College of Engineering 1 , Madurai, Tamil Nadu, India
Department of Electronics and Communication Engineering, KLN College of Engineering 2 , Madurai, Tamil Nadu, India
Department of Mechanical Engineering, Yeshwantrao Chavan College of Engineering 3 , Nagpur, India
School of Electrical Engineering, Vellore Institute of Technology 4 , Chennai, Tamil Nadu, India
College of Computer Science, King Khalid University 5 , Abha 62521, Saudi Arabia
Saveetha School of Engineering, SIMATS 6 , Chennai 602105, Tamil Nadu, India
Funding
Deanship of Scientific Research, King Khalid University
References (25)
Show source-provided references
1. Microstrip patch antenna for breast cancer detection
2. Biomedical application of microstrip patch antenna
3. Metasurface loaded high gain antenna based microwave imaging using iteratively corrected delay multiply and sum algorithm
10.1038/s41598-019-53857-0 ↗4. A printed compact UWB Vivaldi antenna with hemi cylindrical slots and directors for microwave imaging applications
10.1016/j.aeue.2019.152870 ↗10. On-body microstrip patch antenna for breast cancer detection
11. Meta-wearable antennas—A review of metamaterial based antennas in wireless body area networks
10.3390/ma14010149 ↗12. Microwave imaging for early breast cancer detection: Current state, challenges, and future directions
10.3390/jimaging8050123 ↗13. A review of clothing components in the development of wearable textile antennas: Design and experimental procedure
10.3390/s23063289 ↗15. Design of slotted antenna for breast cancer detection using HFSS
18. Design of low cost wearable microstrip patch antenna for breast cancer detection
19. Breast cancer detection using microstrip patch antenna
20. Wearable - Textile patch antenna using jeans as substrate at 2.45 GHz
21. Flexible antenna array for early breast cancer detection using radiometric technique
22. Miniaturised spiral UWB transparent wearable flexible antenna for breast cancer detection
23. A flexible broadband antenna and transmission line network for a wearable microwave breast cancer detection system
10.2528/pierl14091003 ↗24. Breast cancer detection & tumor localization using four flexible microstrip patch antennas
25. Metamaterial-inspired dual-band frequency-reconfigurable antenna with pattern diversity
10.1049/el.2019.0329 ↗