journal article·2022-08Open access

X‐ray Stain Localization with Near‐Field Ptychographic Computed Tomography

Kirsten Taphorn, Madleen Busse, Johannes Brantl, Benedikt Günther, Ana Diaz, Mirko Holler, Martin Dierolf, Doris Mayr, Franz Pfeiffer, Julia Herzen

Advanced Science· Volume 9· Issue 24

Abstract

Abstract Although X‐ray contrast agents offer specific characteristics in terms of targeting and attenuation, their accumulation in the tissue on a cellular level is usually not known and difficult to access, as it requires high resolution and sensitivity. Here, quantitative near‐field ptychographic X‐ray computed tomography is demonstrated to assess the location of X‐ray stains at a resolution sufficient to identify intracellular structures by means of a basis material decomposition. On the example of two different X‐ray stains, the nonspecific iodine potassium iodide, and eosin Y, which mostly interacts with proteins and peptides in the cell cytoplasm, the distribution of the stains within the cells in murine kidney samples is assessed and compared to unstained samples with similar structural features. Quantitative nanoscopic stain concentrations are in good agreement with dual‐energy micro computed tomography measurements, the state‐of‐the‐art modality for material‐selective imaging. The presented approach can be applied to a variety of X‐ray stains advancing the development of X‐ray contrast agents.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced X-ray Imaging Techniques · X-ray Spectroscopy and Fluorescence Analysis · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Chair of Biomedical Physics Department of Physics School of Natural Sciences Technical University of Munich 85748 Garching Germany

Munich Institute of Biomedical Engineering (MIBE) Technical University of Munich 85748 Garching Germany

Paul Scherrer Institute Villigen 5232 Switzerland

Institute of Pathology Ludwig‐Maximilians‐University 80337 Munich Germany

Department of Diagnostic and Interventional Radiology School of Medicine & Klinikum rechts der Isar Technical University of Munich 81675 München Germany

Institute for Advanced Study Technical University of Munich 85748 Garching Germany

References (51)

Show source-provided references
1. 10.1016/j.ymeth.2009.08.00710.1016/j.ymeth.2009.08.007 ↗
2. 10.1152/japplphysiol.01322.200910.1152/japplphysiol.01322.2009 ↗
3. 10.1038/s41598-018-37394-w10.1038/s41598-018-37394-w ↗
4. 10.1073/pnas.171074211410.1073/pnas.1710742114 ↗
5. 10.1186/1472-6793-9-1110.1186/1472-6793-9-11 ↗
6. 10.1002/dvdy.2185710.1002/dvdy.21857 ↗
7. 10.1080/17460441.2019.162320310.1080/17460441.2019.1623203 ↗
8. Friedrich F. · Dev. X‐Ray Tomogr. VI · 2008 · 7078 · 545
9. 10.1111/j.1365-2818.2008.02142.x10.1111/j.1365-2818.2008.02142.x ↗
10. 10.1371/journal.pgen.002006110.1371/journal.pgen.0020061 ↗
11. 10.1007/s11307-010-0372-310.1007/s11307-010-0372-3 ↗
12. 10.1073/pnas.172086211510.1073/pnas.1720862115 ↗
13. 10.1159/00044238710.1159/000442387 ↗
14. 10.1161/CIRCIMAGING.109.91848210.1161/CIRCIMAGING.109.918482 ↗
15. 10.1155/2019/861740610.1155/2019/8617406 ↗
16. 10.2741/419710.2741/4197 ↗
17. 10.1080/1052029050021998210.1080/10520290500219982 ↗
18. 10.1080/bih.77.1.3.1310.1080/bih.77.1.3.13 ↗
19. 10.1038/s41598-018-19467-y10.1038/s41598-018-19467-y ↗
20. 10.1111/j.1469-7580.2012.01483.x10.1111/j.1469-7580.2012.01483.x ↗
21. Dullin C. · PLoS One · 2017
22. 10.1002/dvdy.13610.1002/dvdy.136 ↗
23. 10.1038/s41598-017-17064-z10.1038/s41598-017-17064-z ↗
24. 10.1111/jmi.1254310.1111/jmi.12543 ↗
25. 10.1038/nature0941910.1038/nature09419 ↗
26. 10.1038/s41598-018-34809-610.1038/s41598-018-34809-6 ↗
27. 10.1073/pnas.090584610710.1073/pnas.0905846107 ↗
28. 10.1038/srep0679610.1038/srep06796 ↗
29. Spragg S. P. · 2003 · 36310.1016/B0-12-227410-5/00218-0 ↗
30. 10.1063/1.499609210.1063/1.4996092 ↗
31. Nowotny R. XMuDat: photon attenuation data on PC.https://www‐nds.iaea.org/publications/iaea‐nds/iaea‐nds‐0195.htm(accessed: April 2022).
32. 10.1364/OPTICA.39942110.1364/OPTICA.399421 ↗
33. Mechlem K. · Med. Imaging 2016: Phys. Med. Imaging · 2016 · 9783
34. 10.1107/S160057751901702810.1107/S1600577519017028 ↗
35. Holler M. · Rev. Sci. Instrum. · 2018 · 89 · 4706
36. 10.1038/s41598-017-05587-410.1038/s41598-017-05587-4 ↗
37. 10.1038/s41566-017-0072-510.1038/s41566-017-0072-5 ↗
38. 10.1088/1748-0221/9/05/C0503210.1088/1748-0221/9/05/C05032 ↗
39. Tinti G. · J. Instrum. · 2015 · 1010.1088/1748-0221/10/03/C03011 ↗
40. 10.1016/j.ultramic.2008.12.01110.1016/j.ultramic.2008.12.011 ↗
41. 10.1038/srep0192710.1038/srep01927 ↗
42. 10.1107/S160057672000177610.1107/S1600576720001776 ↗
43. 10.1126/science.115857310.1126/science.1158573 ↗
44. 10.1364/OE.26.00310810.1364/OE.26.003108 ↗
45. 10.1111/j.1365-2818.1982.tb00405.x10.1111/j.1365-2818.1982.tb00405.x ↗
46. 10.1016/j.jsb.2005.05.00910.1016/j.jsb.2005.05.009 ↗
47. 10.1364/OE.19.02134510.1364/OE.19.021345 ↗
48. 10.1364/OPTICA.2.00025910.1364/OPTICA.2.000259 ↗
49. Attwood D. · 2017
50. 10.1088/0031-9155/21/5/00210.1088/0031-9155/21/5/002 ↗
51. 10.1038/s41586-020-2649-210.1038/s41586-020-2649-2 ↗