journal article·2022-09

Polyaniline‐Based Nanostructure Interface for Signal‐to‐Noise Ratio Enhancement in Potentiometric Enzyme‐Free Biosensors

Shoichi Nishitani, Youyuan Man, Taiga Noguchi, Toshiya Sakata

Advanced Materials Interfaces· Volume 9· Issue 27
Publisher page

Abstract

Abstract Reduction of nonspecific signals (noise) in electrochemical biosensors is important for the realization of enzyme‐free, point‐of‐care (POC) diagnostic devices. In this study, a simple biosensor interface that simultaneously realizes analyte signal enhancement and noise reduction to increase signal‐to‐noise ratio in a field‐effect transistor‐based potentiometric biosensor is proposed. As a proof‐of‐concept, a phytic‐acid‐doped self‐functionalized polyaniline (pAni)‐based nanostructure is designed. It is shown that the incorporation of gold nanoparticles in the nanostructure increases the signal intensity in serotonin sensing. Moreover, the phenylboronic acid moiety in the pAni backbone and porous nanostructure of the pAni nanostructure reduces the interfering noise generated by catecholamines and human serum albumin. It is believed that this study will contribute to the realization of versatile and multiplexed POC diagnostic devices in the future.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Electrochemical Analysis and Applications · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Engineering School of Engineering The University of Tokyo 7‐3‐1 Hongo, Bunkyo‐ku Tokyo 113‐8656 Japan

References (37)

Show source-provided references
1. 10.1038/214986a010.1038/214986a0 ↗
2. 10.1021/ac203019910.1021/ac2030199 ↗
3. 10.1002/elan.20040307810.1002/elan.200403078 ↗
4. Nagy G. · Life Sci. · 2004 · 16 · 1896
5. 10.1016/S0003-2670(00)84916-810.1016/S0003-2670(00)84916-8 ↗
6. 10.1021/acsami.9b1930910.1021/acsami.9b19309 ↗
7. 10.1016/j.cbpa.2006.09.01810.1016/j.cbpa.2006.09.018 ↗
8. 10.1073/pnas.120263610910.1073/pnas.1202636109 ↗
9. 10.1038/ncomms294110.1038/ncomms2941 ↗
10. 10.1038/ncomms400210.1038/ncomms4002 ↗
11. 10.1039/C5TB00090D10.1039/C5TB00090D ↗
12. 10.1039/C9SC02033K10.1039/C9SC02033K ↗
13. 10.1038/s41565-019-0566-z10.1038/s41565-019-0566-z ↗
14. 10.1021/nn400482d10.1021/nn400482d ↗
15. 10.1021/acsami.8b2001010.1021/acsami.8b20010 ↗
16. 10.1016/j.electacta.2020.13763110.1016/j.electacta.2020.137631 ↗
17. 10.1002/chem.20070073410.1002/chem.200700734 ↗
18. 10.1016/j.bios.2014.08.08310.1016/j.bios.2014.08.083 ↗
19. 10.1021/cm802314h10.1021/cm802314h ↗
20. 10.1134/S106193481901004010.1134/S1061934819010040 ↗
21. 10.1002/(SICI)1099-0690(200005)2000:9<1703::AID-EJOC1703>3.0.CO;2-S10.1002/(SICI)1099-0690(200005)2000:9<1703::AID-EJOC1703>3.0.CO;2-S ↗
22. 10.1021/ja005906j10.1021/ja005906j ↗
23. 10.1021/acs.jmedchem.9b0080310.1021/acs.jmedchem.9b00803 ↗
24. 10.1149/1.324659210.1149/1.3246592 ↗
25. 10.1021/ja307308j10.1021/ja307308j ↗
26. 10.1021/acssensors.8b0072610.1021/acssensors.8b00726 ↗
27. 10.1016/j.bios.2018.02.01310.1016/j.bios.2018.02.013 ↗
28. 10.1016/j.molstruc.2013.02.01310.1016/j.molstruc.2013.02.013 ↗
29. 10.1021/acs.chemrev.1c0004410.1021/acs.chemrev.1c00044 ↗
30. 10.1021/acs.chemrev.9b0073910.1021/acs.chemrev.9b00739 ↗
31. 10.1021/acssensors.1c0039010.1021/acssensors.1c00390 ↗
32. 10.1021/acs.analchem.9b0238610.1021/acs.analchem.9b02386 ↗
33. 10.1021/acs.analchem.1c0008910.1021/acs.analchem.1c00089 ↗
34. 10.1038/s41596-020-0390-910.1038/s41596-020-0390-9 ↗
35. 10.1371/journal.pone.014128210.1371/journal.pone.0141282 ↗
36. 10.1021/cr980039a10.1021/cr980039a ↗
37. 10.1038/nprot.2016.03010.1038/nprot.2016.030 ↗