High-Throughput Microfluidic Particle Counter Based on Optical Absorption
Source abstract
Abstract
With the utilization of advanced microfluidic techniques, the microfluidic particle counter demonstrates significant potential due to its high efficiency, precise manipulation, and portability. This work focuses on a photodetection counter based on optical absorption. To achieve precise particle detection, a Christmas tree-like structure was implemented to separate a single particle from a cluster, which was then detected in independent multiple parallel channels. The system exhibits a high degree of reliability, as evidenced by a linear correlation coefficient over 0.99 obtained during testing with gradient-concentrated beads. Furthermore, when the calculated density of NIH 3T3 cells is compared with that of a traditional flow cytometer, the system achieves a substantial agreement percentage ranging from 87.5 to 99.9%. The system's ability to perform high-throughput analysis with a high acquisition rate positions it as a promising tool for real-time point-of-care testing.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Bio-sensing Technologies · Electrowetting and Microfluidic Technologies · Biosensors and Analytical Detection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Thrust of Advanced Materials, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou 511400, China
Division of Emerging Interdisciplinary Areas, Interdisciplinary Program Office, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon 999077, Hong Kong
Department of Physics, The Hong Kong University of Science and Technology, Kowloon 999077, Hong Kong
Funding
Innovation and Technology Fund
References (36)
Show source-provided references
1. 10.1007/s00216-005-3335-910.1007/s00216-005-3335-9 ↗
2. 10.1088/1758-5090/ac39a910.1088/1758-5090/ac39a9 ↗
3. 10.1016/j.jqsrt.2014.06.00710.1016/j.jqsrt.2014.06.007 ↗
4. 10.1088/0957-0233/24/12/12510310.1088/0957-0233/24/12/125103 ↗
5. Dittrich, W.; Gohde, W. Flow-through chamber for photometers to measure and count particles in a dispersion medium. U.S. Patent 3,761,187 A, 1973.
6. 10.1364/OE.17.00606810.1364/OE.17.006068 ↗
7. 10.1021/acsbiomaterials.8b0090410.1021/acsbiomaterials.8b00904 ↗
8. 10.1021/acsbiomaterials.2c0037810.1021/acsbiomaterials.2c00378 ↗
9. 10.1021/acsbiomaterials.0c0098010.1021/acsbiomaterials.0c00980 ↗
10. 10.1038/s41565-023-01560-710.1038/s41565-023-01560-7 ↗
11. 10.1021/acs.chemrev.6b0084810.1021/acs.chemrev.6b00848 ↗
12. 10.3390/mi1409172210.3390/mi14091722 ↗
13. 10.1002/smll.20190753410.1002/smll.201907534 ↗
14. 10.1073/pnas.160692711310.1073/pnas.1606927113 ↗
15. 10.1109/JSTQE.2015.241491210.1109/JSTQE.2015.2414912 ↗
16. 10.1002/elps.20140021110.1002/elps.201400211 ↗
17. Dannhauser D. · 2013 · 152
18. Coulter, W. H. Means for counting particles suspended in a fluid. U.S. Patent 2,656,508 A, 1953.
19. 10.1109/TBCAS.2013.227509110.1109/TBCAS.2013.2275091 ↗
20. 10.1016/j.aca.2010.09.03510.1016/j.aca.2010.09.035 ↗
21. 10.1016/j.triboint.2022.10760910.1016/j.triboint.2022.107609 ↗
22. 10.1007/s10404-010-0627-y10.1007/s10404-010-0627-y ↗
23. 10.3390/jfb1404020810.3390/jfb14040208 ↗
24. 10.1016/j.sna.2021.11304710.1016/j.sna.2021.113047 ↗
25. 10.1039/b601886f10.1039/b601886f ↗
26. 10.1002/jemt.2093710.1002/jemt.20937 ↗
27. 10.1039/b912547g10.1039/b912547g ↗
28. 10.1007/s10404-013-1291-910.1007/s10404-013-1291-9 ↗
29. 10.1038/s41598-017-06946-x10.1038/s41598-017-06946-x ↗
30. 10.1039/C7LC00678K10.1039/C7LC00678K ↗
31. 10.1002/ijc.291051051310.1002/ijc.2910510513 ↗
32. 10.18632/oncotarget.2798110.18632/oncotarget.27981 ↗
33. Jen L. W. · Int. J. Infrastruct. Res. Manag. · 2023 · 11 · 53
34. 10.1007/s10544-010-9474-610.1007/s10544-010-9474-6 ↗
35. abcam Cell culture preparation and plating protocol. https://www.abcam.com/protocols/cell-culture-preparation-and-plating-protocol.
36. 10.3390/cells1117267710.3390/cells11172677 ↗