4. Hemodynamic Bedside Monitoring Instrument with Pressure and Optical Sensors: Validation and Modality Comparison
10.1002/advs.202307718 ↗6. W.Shi L.Mi Z.Dai C.Chen W.Luo W.Guo andG.Wang “Live Demonstration: Yupei: A Flexible Wireless Multi‐Physiological Parameters Wearable Device for NICU ” in2024 IEEE Biomedical Circuits and Systems Conference (BioCAS)(IEEE 2024) 1–2.
10.1109/BioCAS61083.2024.10798205 ↗9. Binodal, Wireless Epidermal Electronic Systems with In‐Sensor Analytics for Neonatal Intensive Care
10.1126/science.aau0780 ↗10. Skin‐Interfaced Biosensors for Advanced Wireless Physiological Monitoring in Neonatal and Pediatric Intensive‐Care Units
10.1038/s41591-020-0792-9 ↗11. Advancing Wearable Biosensors for Congenital Heart Disease: Patient and Clinician Perspectives: A Science Advisory from the American Heart Association
10.1161/CIR.0000000000001225 ↗12. Synchronized Wearables for the Detection of Haemodynamic States via Electrocardiography and Multispectral Photoplethysmography
10.1038/s41551-023-01098-y ↗13. Wireless, Skin‐Interfaced Devices for Pediatric Critical Care: Application to Continuous, Noninvasive Blood Pressure Monitoring
10.1002/adhm.202100383 ↗14. Neonatal Wearable Device for Colorimetry‐Based Real‐Time Detection of Jaundice with Simultaneous Sensing of Vitals
10.1126/sciadv.abe3793 ↗19. G.Nie J.Zhu G.Tang et al. “A Review of Deep Learning Methods for Photoplethysmography Data ”arXivpreprint arXiv:2401.12783 (2024).
20. PCA‐Based Multi‐Wavelength Photoplethysmography Algorithm for Cuffless Blood Pressure Measurement on Elderly Subjects
10.1109/JBHI.2020.3004032 ↗21. Z.Hou D.Huang Y.Huang et al. “Exploiting Multi‐Wavelength Morphological Features of Camera‐PPG for Blood Pressure Estimation ”IEEE Transactions on Instrumentation and Measurement(2025).
10.1109/TIM.2025.3551005 ↗22. The Past, Current, and Future of Neonatal Intensive Care Units with Artificial Intelligence: A Systematic Review
10.1038/s41746-023-00941-5 ↗23. Feasibility and Measurement Stability of Smartwatch‐Based Cuffless Blood Pressure Monitoring: A Real‐World Prospective Observational Study
10.1038/s41440-023-01215-z ↗26. Feasibility Study for the Non‐Invasive Blood Pressure Estimation Based on PPG Morphology: Normotensive Subject Study
10.1186/s12938-016-0302-y ↗29. Multi‐Wavelength Photoplethysmography Enabling Continuous Blood Pressure Measurement with Compact Wearable Electronics
10.1109/TBME.2018.2874957 ↗30. Signal‐Quality Indices for the Electrocardiogram and Photoplethysmogram: Derivation and Applications to Wireless Monitoring
31. “Non‐Invasive Sphygmomanometers—Part 2: Clinical Investigation of Intermittent Automated Measurement Type ”International Organization for Standardization Standard ISO 81060‐2:2018 (2018) amendments: 2020 2024.
32. “IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices ”Institute of Electrical and Electronics Engineers Standard IEEE Std 1708‐2014 (2014).
33. “IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices—Amendment 1 ”Institute of Electrical and Electronics Engineers Standard IEEE Std 1708a‐2019 (2019) clarifications on cohort selection posture/activity applicability and motion artifacts.
34. The British Hypertension Society Protocol for the Evaluation of Blood Pressure Measuring Devices
35. PulseDB: A Large, Cleaned Dataset Based on MIMIC‐III and VitalDB for Benchmarking Cuff‐Less Blood Pressure Estimation Methods
10.3389/fdgth.2022.1090854 ↗36. Q.Hong C.Bian X.Zhou X.Li Y.Li andZ.Zeng “Lost in Time? A Meta‐Learning Framework for Time‐Shift‐Tolerant Physiological Signal Transformation ” inProceedings of the AAAI Conference on Artificial Intelligence40(2026) 21761–21769.
10.1609/aaai.v40i26.39327 ↗38. B.Liu H.Wu G.Wang J.Chen C.Chen andG. K. H.Pang “Ring‐BP: Using a Wearable Smart Ring to Cufflessly Estimate Blood Pressure with Mobile and Efficient Net ” in2025 IEEE 7th International Conference on Artificial Intelligence Circuits and Systems (AICAS)(2025) 1–5.
10.1109/AICAS64808.2025.11173101 ↗39. S.Abbaspourazad O.Elachqar A. C.Miller S.Emrani U.Nallasamy andI.Shapiro “Large‐Scale Training of Foundation Models for Wearable Biosignals ”arXivpreprint arXiv:2312.05409 (2023).
40. Multi‐Channel Masked Autoencoder and Comprehensive Evaluations for Reconstructing 12‐Lead ECG from Arbitrary Single‐Lead ECG
10.1038/s44325-024-00036-4 ↗41. Does Measurement of Four‐Limb Blood Pressures at Birth Improve Detection of Aortic Arch Anomalies?
10.1038/jp.2015.203 ↗42. Comparison of Calf and Brachial Blood Pressures in Infants: Is There a Difference Between Calf and Brachial Blood Pressures?
10.1016/j.jvn.2014.03.003 ↗