Review—Glucose Monitoring Sensors: History, Principle, and Challenges
Source abstract
Abstract
Blood glucose monitoring is a valuable tool for managing diabetes. In recent years, with the increase of diabetics in the world, continuous monitoring of blood sugar changes has attracted more and more researchers’ attention. Among the current technologies for measuring glucose, optical and electrochemical glucose sensors are the mainstream ones. This article introduces the history of optical, electrochemical, and other sensors such as field effect transistors sensors and their advantages and disadvantages respectively. This review summarizes the research progress and main challenges of continuous glucose monitoring technology. We found that different optical techniques have different limitations which restricts the development of optical CGM. In contrast, electrochemical glucose sensors are more feasible and reliable in implementing CGM. Therefore, this review focuses on the development and shortcomings of electrochemical sensors, especially the promising DET and the current commercial CGM. Hopefully, it will help readers sort out the future of CGM’s development.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Analytical Chemistry and Sensors · Spectroscopy Techniques in Biomedical and Chemical Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Biocompatible materials for continuous glucose monitoring devices10.1021/cr300387j ↗
2. Protection by beta-Hydroxybutyric acid against insulin glycation, lipid peroxidation and microglial cell apoptosis10.1186/s40199-015-0126-5 ↗
3. Piperazine sulfonamides as DPP-IV inhibitors: Synthesis, induced-fit docking and in vitro biological evaluation10.2478/acph-2021-0034 ↗
4. Diabetes, obesity, and the brain10.1126/science.1104344 ↗
5. An international model to predict recurrent cardiovascular disease10.1016/j.amjmed.2012.01.014 ↗
6. Diabetes, Alzheimer disease, and vascular dementia: a population-based neuropathologic study10.1212/WNL.0b013e3181f4d7f8 ↗
7. Not quite type 1 or type 2, what now ? Review of monogenic, mitochondrial, and syndromic diabetes10.1007/s11154-018-9446-3 ↗
8. Review of 2017 diabetes standards of care10.1016/j.cnur.2017.07.010 ↗
9. The value of measuring diabetes burnout10.1007/s11892-021-01392-6 ↗
10. Glucose and sucrose supply regulates the uptake, transport, and metabolism of nitrate in Pak Choi10.2134/agronj2017.09.0541 ↗
11. Quality changes in refrigerated stored minced pork wrapped with plastic cling film and the effect of glucose supplementation10.1016/j.meatsci.2016.12.007 ↗
12. A new type of glucose biosensor based on surface acoustic wave resonator using Mn-doped ZnO multilayer structure10.1016/j.bios.2013.05.021 ↗
13. A fluorescent double-network-structured hybrid nanogel as embeddable nanoglucometer for intracellular glucometry10.1039/c2bm00162d ↗
14. A novel Ag/Zn bimetallic MOF as a superior sensitive biosensing platform for HCV-RNA electrochemical detection10.1016/j.apsusc.2021.150202 ↗
15. Current development in non-invasive glucose monitoring10.1016/j.medengphy.2007.06.003 ↗
16. Stokes-Mueller matrix polarimetry system for glucose sensing10.1016/j.optlaseng.2016.08.017 ↗
17. Photo-acoustic sensor based on an inexpensive piezoelectric film transducer and an amplitude-stabilized single-mode external cavity diode laser for in vitro measurements of glucose concentration10.1016/j.optlastec.2017.12.034 ↗
18. A highly sensitive SERS sensor for quantitative analysis of glucose based on the chemical etching of silver nanoparticles10.1088/2040-8978/17/11/114020 ↗
19. Flattened fiber-optic ATR sensor enhanced by silver nanoparticles for glucose measurement10.1007/s10544-018-0346-9 ↗
20. Recent advances on developing 3rd generation enzyme electrode for biosensor applications10.1016/j.bios.2015.12.055 ↗
21. Electrode systems for continuous monitoring in cardiovascular surgery10.1111/j.1749-6632.1962.tb13623.x ↗
22. Advanced biosensors for glucose and insulin10.1016/j.bios.2019.03.034 ↗
23. A novel improved design for the first-generation glucose biosensor
24. Glucose biosensors: an overview of use in clinical practice10.3390/s100504558 ↗
25. Glucose Biosensors: 40 Years of Advances and Challenges10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-# ↗
26. A glucose biosensor based on direct electrochemistry of glucose oxidase immobilized on nitrogen-doped carbon nanotubes10.1016/j.bios.2009.07.016 ↗
27. Study of direct electron transfer and enzyme activity of glucose oxidase on graphene surface10.1016/j.elecom.2014.10.016 ↗
28. The relationship between a balanced time perspective and self-monitoring of blood glucose among people with type 1 diabetes10.1093/abm/kay028 ↗
29. A review of optical methods for continuous glucose monitoring10.1080/05704928.2018.1486324 ↗
30. Increasing individual target glucose levels to prevent hypoglycemia in patients with diabetes10.4082/kjfm.19.0161 ↗
31. Continuous glucose monitoring: review of an innovation in diabetes management10.1016/j.amjms.2019.07.003 ↗
32. Continuous glucose monitoring: A review of the technology and clinical use10.1016/j.diabres.2017.08.005 ↗
33. Glucose control in adults with type 1 diabetes using a medtronic prototype enhanced-hybrid closed-loop system: a feasibility study10.1089/dia.2019.0120 ↗
34. Accuracy comparison of the dexcom G5, abbott freestyle libre pro, and senseonics eversense continuous glucose monitoring devices in a home-use study of subjects with type 1 diabetes10.1089/dia.2019.0449 ↗
35. From battery enabled to natural harvesting: enzymatic biofuel cell assisted integrated analog front-end in 130nm CMOS for long-term monitoring10.1109/TCSI.2018.2869343 ↗
36. Vanadium oxide thermal microsensor integrated in a microfluidic chip for detecting cholesterol and glucose concentrations10.1007/s00542-016-3090-1 ↗
37. Microbial glucose biosensors based on glassy carbon paste electrodes modified with Gluconobacter Oxydans and graphene oxide or graphene-platinum hybrid nanoparticles10.1007/s00604-015-1590-9 ↗
38. Screen printed electrodes in biosensors and bioassays. a review10.20964/2020.11.19 ↗
39. Optical glucose sensor using pressure sensitive paint10.3390/s21134474 ↗
40. An overview of wearable and implantable electrochemical glucose sensors10.1002/elan.202100273 ↗
41. Biofuel cells and inductive powering as energy harvesting techniques for implantable sensors10.1166/sam.2011.1175 ↗
42. Pyrroloquinoline quinone glucose dehydrogenase adopted in thermometric analysis for enhancement of glucose determination10.1007/s10973-018-7273-0 ↗
43. Microbial based sensor for the measurement of glucose in serum and urine
44. Screen-printed electrodes: promising paper and wearable transducers for (Bio)sensing10.3390/bios10070076 ↗
45. Continuous glucose monitors: The long-awaited watch dogs ?10.1089/dia.2007.0215 ↗
46. Performance of the freestyle libre flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus10.1136/bmjdrc-2016-000320 ↗
47. Glucose sensing using surface-enhanced raman-mode constraining10.1021/acs.analchem.8b03420 ↗
48. Long-term continuous glucose monitoring using a fluorescence-based biocompatible hydrogel glucose sensor10.1002/adhm.202001286 ↗
49. In vivo evaluation of a chip based near infrared sensor for continuous glucose monitoring10.1016/j.bios.2013.09.043 ↗
50. Optical surface plasmon resonance sensor modified by mutant glucose/galactose-binding protein for affinity detection of glucose molecules10.1364/BOE.8.005206 ↗
51. Effects of spectral resolution on the determination of glucose in a simulated biological matrix by Fourier transform near infrared spectrometry10.1255/jnirs.680 ↗
52. Iris as a reflector for differential absorption low-coherence interferometry to measure glucose level in the anterior chamber10.1117/1.3528658 ↗
53. Raman techniques: fundamentals and frontiers10.1186/s11671-019-3039-2 ↗
54. Quantitative analysis using Raman spectroscopy without spectral standardization10.1002/(SICI)1097-4555(199909)30:9<767::AID-JRS447>3.0.CO;2-J ↗
55. Progress toward an in vivo surface-enhanced Raman spectroscopy glucose sensor10.1089/dia.2007.0288 ↗
56. Monitoring of heat- and light exposure of cell culture media by RAMAN spectroscopy: Towards an analytical tool for cell culture media quality control10.1016/j.bej.2020.107845 ↗
57. Progress toward an in vivo surface-enhanced Raman spectroscopy glucose sensor10.1089/dia.2007.0288 ↗
58. Glucose oxidase probe as a surface-enhanced Raman scattering sensor for glucose10.1007/s00216-016-9849-5 ↗
59. Noninvasive glucose sensing by transcutaneous Raman spectroscopy10.1117/1.JBO.20.5.051036 ↗
60. Critical-depth Raman spectroscopy enables home-use non-invasive glucose monitoring10.1371/journal.pone.0197134 ↗
61. Glucose sensors: a review of current and emerging technology10.1111/j.1464-5491.2008.02642.x ↗
62. Infrared measurements of glucose in peritoneal fluid with a tuneable quantum cascade laser10.1364/BOE.393617 ↗
63. Application of factorial experimental design on the optical absorption from glucose–insulin samples in mid-infrared spectroscopy10.1016/j.rinp.2019.102170 ↗
64. Noninvasive in vivo glucose sensing on human subjects using mid-infrared light10.1364/BOE.5.002397 ↗
65. Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring10.1016/j.snb.2019.01.121 ↗
66. Integrated catheter system for continuous glucose measurement and simultaneous insulin infusion10.1016/j.bios.2014.08.012 ↗
67. First step toward near-infrared continuous glucose monitoring: in vivo evaluation of antibody coupled biomaterials10.1177/1535370214554878 ↗
68. Long-term in vivo glucose monitoring using fluorescent hydrogel fibers10.1073/pnas.1104954108 ↗
69. Genetic engineering of an allosterically based glucose indicator protein for continuous glucose monitoring by fluorescence resonance energy transfer10.1021/ac034022q ↗
70. Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions10.1016/j.bios.2020.112331 ↗
71. , Disposable Sensors in Diagnostics, Food, and Environmental Monitoring10.1002/adma.201806739 ↗
72. Fundamentals, achievements and challenges in the electrochemical sensing of pathogens10.1039/C5AN01330E ↗
73. Non-enzymatic electrochemical sensing of glucose10.1007/s00604-012-0923-1 ↗
74. Recent advances in non-enzymatic electrochemical glucose sensors based on non-precious transition metal materials: opportunities and challenges10.1039/C6RA12506A ↗
75. Nonenzymatic glucose sensors
76. Optical glucose sensing using ethanolamine-polyborate complexes10.1039/C7TB01790A ↗
77. Carbon nanomaterial hybrids via laser writing for high-performance non-enzymatic electrochemical sensors: a critical review10.1007/s00216-021-03382-9 ↗
78. A patch type non-enzymatic biosensor based on 3D SUS micro-needle electrode array for minimally invasive continuous glucose monitoring10.1016/j.snb.2015.08.013 ↗
79. Fluorescent chemosensors for carbohydrates: A decade’s worth of bright spies for saccharides in review10.1023/B:JOFL.0000039344.34642.4c ↗
80. Boronic acid building blocks: tools for sensing and separation10.1039/c0cc02920c ↗
81. Synthesis of diboronic acid-based fluorescent probes for the sensitive detection of glucose in aqueous media and biological matrices10.1021/acssensors.0c02217 ↗
82. Advanced biosensors for glucose and insulin10.1016/j.bios.2019.03.034 ↗
83. Biosensor for continuos glucose monitoring10.1002/bit.260430310 ↗
84. A single nanowire sensor for intracellular glucose detection10.1039/C9NR01997A ↗
85. Developing glucose sensors for in vivo use10.1016/0167-7799(93)90016-3 ↗
86. Characterization of glucose oxidase-modified poly(phenylenediamine)-coated electrodes in-vitro and in-vivo - homogeneous interference by ascorbic-acid in hydrogen-peroxide detection10.1021/ac00082a025 ↗
87. Electron-transfer between glucose-oxidase and electrodes via redox mediators bound with flexible chains to the enzyme surface10.1021/ja00004a048 ↗
88. Minimally invasive glucose monitoring using a highly porous gold microneedles-based biosensor: characterization and application in artificial interstitial fluid10.3390/catal9070580 ↗
89. Recent developments in blood glucose sensors10.1016/j.jfda.2014.12.001 ↗
90. Recent advances in electrochemical glucose biosensors: a review10.1039/c2ra22351a ↗
91. Amperometric glucose sensing at nanomolar level using MOF-encapsulated TiO2 platform10.1021/acsomega.8b01968 ↗
92. Mussel-inspired enzyme immobilization and dual real-time compensation algorithms for durable and accurate continuous glucose monitoring10.1016/j.bios.2019.111622 ↗
93. Amperometric biosensors based on direct electron transfer enzymes10.3390/molecules26154525 ↗
94. Direct electrochemistry of glucose oxidase based on one step electrodeposition of reduced graphene oxide incorporating polymerized l-lysine and its application in glucose sensing10.1016/j.msec.2019.109880 ↗
95. Rate-structure dependencies for intramolecular electron transfer via organic anchoring groups at metal surfaces10.1021/j100407a060 ↗
96. Direct electrochemistry of redox proteins and enzymes promoted by carbon nanotubes10.3390/s5040220 ↗
97. Direct electron transfer of glucose oxidase and biosensing for glucose based on PDDA-capped gold nanoparticle modified graphene/multi-walled carbon nanotubes electrode10.1016/j.bios.2013.08.043 ↗
98. Direct-electron-transfer bio-nanoink with single-walled carbon nanotube and aspergillus terreus var. aureus flavin adenine dinucleotide glucose dehydrogenase10.1021/acsomega.9b00060 ↗
99. Direct electron transfer from glucose oxidase immobilized on a nano-porous glassy carbon electrode10.1016/j.electacta.2011.08.106 ↗
100. Direct electrochemistry of glucose oxidase based on one step electrodeposition of reduced graphene oxide incorporating polymerized l-lysine and its application in glucose sensing10.1016/j.msec.2019.109880 ↗