Stent-graft compliance modulates regional mechanical and structural remodeling of the aorta
Source abstract
Abstract
Endovascular aortic stent-grafts often introduce a compliance mismatch with the native aorta, potentially leading to adverse remodeling. This study assessed how stent-graft compliance affects structural, mechanical, and morphometric adaptation in a porcine model by comparing a conventional stiff polyethylene terephthalate stent-graft (CS-SG) to a compliant nanofibrillar stent-graft (NF-SG). Four months after implantation, aortas were harvested and systematically analyzed. Morphometric assessment of aortic rings, planar biaxial mechanical testing, and quantification of elastin, collagen, and smooth muscle cell (SMC) densities were performed. Remodeling with the CS-SG was primarily localized to regions under stent contact and included increased collagen accumulation (∼25-30 % vs. ∼15 % in the inner media), elastin compaction, significant loss of SMCs (∼10-15 % vs. ∼20-25 % in inner media), and thick neointima formation. These changes were associated with increased aortic stiffness (0.47 MPa vs. 0.37 MPa) and loss of non-linearity, especially in distal stented segments, while remote regions exhibited minimal alterations. In contrast, NF-SG implantation was associated with fewer localized structural and mechanical changes, including preserved SMC density, reduced collagen accumulation, reduced neointima formation, and maintained compliance at stented and adjacent regions. Overall, these findings suggest that compliant stent-grafts may mitigate localized adverse remodeling at stent-tissue interfaces compared to conventional stiff devices. These results highlight the potential importance of compliance-matching in stent-graft design, although broader effects across the aorta were limited within the four-month observation period. Future studies in diseased and aged models with extended follow-up are warranted. STATEMENT OF SIGNIFICANCE: This study quantifies morphological, mechanical, and structural changes in the porcine aorta four months after implantation of either a stiff or a compliant stent-graft. Aortic remodeling was highly localized, occurring primarily in the stented and distal segments, with minimal changes in regions remote from the stent-graft. Our results demonstrate that compliant stent-grafts better preserve aortic structure, smooth muscle cell density, and mechanical function compared to stiff devices, which induce pronounced pathological changes in areas directly exposed to stent contact. These findings underscore the clinical importance of designing more compliant stent-grafts to mitigate adverse vascular remodeling and improve long-term outcomes after endovascular aortic repair.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Aortic aneurysm repair treatments · Coronary Interventions and Diagnostics · Aortic Disease and Treatment Approaches
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Thoracic aortic aneurysm and dissection10.1016/j.jacc.2014.08.025 ↗
2. Management of blunt thoracic aortic injury10.1016/j.ejvs.2005.06.031 ↗
3. Five-year results of thoracic endovascular aortic repair with the Zenith TX210.1016/j.jvs.2014.01.043 ↗
4. A significant proportion of current endovascular aortic aneurysm repair practice fails to meet Society for Vascular Surgery clinical practice guideline recommended abdominal aortic aneurysm diameter treatment thresholds in the Vascular Quality Initiative10.1016/j.jvs.2021.08.109 ↗
5. Cardiac and aortic modifications after endovascular repair for blunt thoracic aortic injury: a systematic review10.1016/j.ejvs.2022.05.004 ↗
6. Long-term reintervention after endovascular abdominal aortic aneurysm repair10.1097/SLA.0000000000003446 ↗
7. Cardiovascular remodeling after endovascular treatment for thoracic aortic injury10.1016/j.avsg.2019.04.015 ↗
8. Stent-graft deployment increases aortic stiffness in an ex vivo porcine model10.1016/j.avsg.2017.04.024 ↗
9. Increased pulse wave velocity and arterial hypertension in young patients with thoracic aortic endografts10.1016/j.avsg.2011.06.021 ↗
10. Endovascular repair of blunt thoracic aortic trauma is associated with increased left ventricular mass, hypertension, and off-target aortic remodeling10.1097/SLA.0000000000003768 ↗
11. Effect of endoprostheses on pulse wave velocity and its long-term outcomes after thoracic endovascular aortic repair10.1007/s11748-020-01343-0 ↗
12. Associations of aortic Windkessel function with age, gender and cardiovascular risk factors10.1016/S0301-5629(01)00445-8 ↗
13. TEVAR and EVAR, the unknown knowns of the cardiovascular hemodynamics; and the immediate and long-term consequences of fabric material on major adverse clinical outcome10.3389/fsurg.2022.940304 ↗
14. Differential effects of stent-graft fabrics on arterial stiffness in patients undergoing endovascular aneurysm repair10.1583/14-4772MR.1 ↗
15. Endovascular repair of blunt thoracic aortic trauma: is postimplant hypertension an incidental finding?10.1016/j.avsg.2018.01.100 ↗
16. Long-term efficacy of EVAR in patients aged less than 65 years with an infrarenal abdominal aortic aneurysm and favorable anatomy10.1016/j.avsg.2020.03.038 ↗
17. Mechanically tuned vascular graft demonstrates rapid endothelialization and integration into the porcine iliac artery wall10.1016/j.actbio.2021.01.047 ↗
18. Effect of stent-graft length and compliance on aortic hemodynamics in a bench-top physiological flow circuit10.1016/j.jmbbm.2025.107269 ↗
19. Effect of stent-graft compliance on hemodynamics and aortic stiffening in an in vivo porcine study
20. Windkessel preserving aortic stent graft attenuates left ventricular remodelling after thoracic endovascular aortic repair in a porcine model10.1016/j.ejvs.2026.02.015 ↗
21. Mechanical, structural, and physiologic differences in human elastic and muscular arteries of different ages: comparison of the descending thoracic aorta to the superficial femoral artery10.1016/j.actbio.2020.10.035 ↗
22. Homocysteine leads to aortic stiffening in a rabbit model of atherosclerosis10.1016/j.actbio.2025.06.003 ↗
23. Effects of stenting on adjacent vascular distensibility and neointima formation: role of nitric oxide10.1177/1358836X0100600303 ↗
24. Vascular compliance changes of the coronary vessel wall after bioresorbable Vascular scaffold implantation in the treated and adjacent segments10.1253/circj.CJ-11-1416 ↗
25. Changes in wall mechanics after endovascular stenting in the rabbit aorta: comparison of three stent designs10.2214/ajr.176.3.1760803 ↗
26. Biomechanical and histological analyses of a multilayer stent in a swine model of suprarenal aortic aneurysm
27. Histologic analysis of stent graft oversizing in the thoracic aorta10.1016/j.jvs.2013.02.005 ↗
28. Histologic analysis with the newly designed exoskeleton seal® stent-graft in the porcine abdominal aorta10.1007/s00270-019-02261-2 ↗
29. Early histological changes in the porcine aortic Media after thoracic stent-graft implantation10.1583/12-3845R.1 ↗
30. Histological changes in Canine aorta 1 year after stent-graft implantation: implications for the long-term stability of device anchoring zones10.1177/152660280200900311 ↗
31. An experimental investigation of the impact of thoracic endovascular aortic repair on longitudinal strain10.1093/ejcts/ezw180 ↗
32. Global and local stiffening of ex vivo-perfused stented human thoracic aortas: a mock circulation study10.1016/j.actbio.2023.02.028 ↗
33. TEVAR versus open aortic arch replacement in ex vivo perfused human thoracic aortas10.1016/j.actbio.2024.12.019 ↗
34. Histological evaluation of a self-expanding stent-graft 23 months after implantation in the superficial femoral artery10.1177/1526602817719881 ↗
35. Influence of shape-memory stent grafts on local aortic compliance10.1007/s10237-021-01514-9 ↗
36. Associations between collagen synthesis and degradation and aortic function in arterial hypertension10.1038/ajh.2010.2 ↗
37. How vascular smooth muscle cell phenotype switching contributes to vascular disease10.1186/s12964-022-00993-2 ↗
38. Mechanical and structural changes in human thoracic aortas with age10.1016/j.actbio.2019.12.024 ↗
39. Residual strains in conduit arteries10.1016/S0021-9290(02)00444-X ↗
40. Flexible tantalum stents implanted in aortas and iliac arteries: effects in normal canines10.1148/radiology.175.1.2315508 ↗
41. Vascular stenting in normal and atherosclerotic rabbits. Studies of the intravascular endoprosthesis of titanium-nickel-alloy10.1161/01.CIR.81.2.667 ↗
42. Arterial stenting and overdilation: does it change wall mechanics in small-caliber arteries?10.1177/152660280200900620 ↗
43. Distal stent graft-induced new entry: an emerging complication of endovascular treatment in aortic dissection10.1016/j.athoracsur.2016.02.001 ↗
44. A numerical assessment of wall shear stress changes after endovascular stenting10.1016/j.jbiomech.2004.09.011 ↗
45. The effects of extremely low shear stress on cellular proliferation and neointimal thickening in the failing bypass graft10.1067/mva.2001.114819 ↗
46. Variations in stiffness and structure of the human aorta along its length10.1038/s41598-025-95008-8 ↗