Preserving tissue integrity under the beam: high-energy, low-dose synchrotron CT for in situ imaging of bovine intervertebral discs
Source abstract
Abstract
In situ tomography enables non-destructive, time-lapse imaging of biological tissues under load, offering insights into structural and mechanical changes. However, repeated scans can expose samples to high radiation doses, potentially altering tissue properties. This study evaluated the feasibility of low-dose synchrotron computed tomography (sCT) for high-resolution, in situ imaging of intact bovine intervertebral discs (IVDs), and assessed the effects of repeated x-ray exposure on mechanical, microstructural, and molecular integrity. Intact oxtail IVD segments were imaged using propagation-based phase contrast sCT at 54 keV. Scan parameters were optimised to achieve high image quality within 66 s per scan, resulting in a total absorbed dose of ∼30 kGy over six scans. Mechanical properties were assessed under cyclic loading, microstructural changes via digital volume correlation (DVC), and molecular alterations using Raman spectroscopy. High-resolution imaging of soft and calcified tissues was achieved. Changes in sample stiffness, hysteresis, or stress recovery between irradiated and control were not identified. DVC revealed no microstructural damage or strain accumulation in the calcified endplate. Raman spectroscopy indicated minimal changes in soft tissues, with bone showing slightly increased collagen crosslinking and reduced mineralisation. Overall, this study demonstrates that high-energy, low-dose sCT enables repeated imaging of musculoskeletal tissues without compromising integrity, supporting its application in dynamic, time-lapse imaging studies. Importantly, larger, intact samples, such as whole bovine IVDs, were imaged overcoming limitations of previous studies that relied on small animal models. This approach supports more physiologically relevant investigations of tissue mechanics and degeneration in complex systems. STATEMENT OF SIGNIFICANCE: This study demonstrates the feasibility of high-resolution, low-dose phase contrast synchrotron computed tomography (sCT) for in situ imaging of intact bovine intervertebral discs (IVDs), preserving mechanical, microstructural, and molecular integrity. By optimising scan parameters to achieve 66-second acquisitions at 54 keV, the total radiation dose was limited to ∼30 kGy - below the frequently cited threshold for tissue damage. Unlike previous studies constrained to small animal models, this work successfully applies these imaging capabilities to larger, more physiologically relevant samples, representing an important step toward models that better reflect native biomechanics. Importantly, no adverse effects were observed in tissue mechanics or microstructure, and only minimal molecular changes were detected. These findings support the use of high-energy, low-dose sCT for dynamic, multi-scan imaging of musculoskeletal tissues, enabling more accurate investigations of tissue biomechanics and degeneration.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Spine and Intervertebral Disc Pathology · Advanced X-ray Imaging Techniques · Bone health and osteoporosis research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. A review of techniques for visualising soft tissue microstructure deformation and quantifying strain ex vivo10.1111/jmi.12701 ↗
2. MicroCT for comparative morphology: simple staining methods allow high-contrast 3D imaging of diverse non-mineralized animal tissues10.1186/1472-6793-9-11 ↗
3. Synchrotron X-ray imaging of soft biological tissues–principles, applications and future prospects10.1242/jcs.261953 ↗
4. Development of a method to investigate strain distribution across the cartilage-bone interface in guinea pig model of spontaneous osteoarthritis using lab-based contrast enhanced X-ray-computed tomography and digital volume correlation10.1016/j.jmbbm.2023.105999 ↗
5. A practical guide for in situ mechanical testing of musculoskeletal tissues using synchrotron tomography10.1016/j.jmbbm.2022.105297 ↗
6. Imaging intact human organs with local resolution of cellular structures using hierarchical phase-contrast tomography10.1038/s41592-021-01317-x ↗
7. Sub-trabecular strain evolution in human trabecular bone10.1038/s41598-020-69850-x ↗
8. Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation10.1016/j.jmbbm.2018.08.012 ↗
9. In situ characterization of nanoscale strains in loaded whole joints via synchrotron X-ray tomography
10. Gaining insight into the deformation of achilles tendon entheses in mice10.1002/adem.202100085 ↗
11. Time-resolved in situ synchrotron-microCT: 4D deformation of bone and bone analogues using digital volume correlation10.1016/j.actbio.2021.06.014 ↗
12. Preservation of bone tissue integrity with temperature control for in situ SR-microCT experiments10.3390/ma11112155 ↗
13. Quantification of 3D microstructures in Achilles tendons during in situ loading reveals anisotropic fiber response10.1016/j.actbio.2025.01.023 ↗
14. Primary radiation damage in bone evolves via collagen destruction by photoelectrons and secondary emission self-absorption10.1038/s41467-022-34247-z ↗
15. Regional variations in discrete collagen fibre mechanics within intact intervertebral disc resolved using synchrotron computed tomography and digital volume correlation10.1016/j.actbio.2021.10.012 ↗
16. Characterization of the effects of x-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone10.1016/j.biomaterials.2011.08.013 ↗
17. Effect of radiation-induced damage of trabecular bone tissue evaluated using indentation and digital volume correlation10.1016/j.jmbbm.2022.105636 ↗
18. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms10.1016/j.jbiomech.2017.04.007 ↗
19. I12: the joint engineering, environment and processing (JEEP) beamline at diamond light source10.1107/S1600577515003513 ↗
20. Characterisation of phase-contrast and phase-retrieval X-ray tomography techniques at the I12-JEEP beamline10.1016/j.nima.2025.170262 ↗
21. Wadeson, N. and Basham, M., 2016. Savu: a python-based, MPI framework for simultaneous processing of multiple, N-dimensional, large tomography datasets. arXiv preprint, arXiv:1610.08015. Available at: https://arxiv.org/abs/1610.08015 [Accessed 24 February 2026].
22. Superior techniques for eliminating ring artifacts in X-ray micro-tomography10.1364/OE.26.028396 ↗
23. Blind image quality evaluation using perception based features
24. D.G.F. Hasgall PA, Baumgartner C, Neufeld E, Lloyd B, Gosselin MC, Payne D, Klingenböck A, Kuster N, , Tissue properties Database V4-1. DOI: 10.13099/VIP21000-04-1, IT'IS Foundation, itis.swiss/database, 2022.
25. Berger · 2010
26. Influence of testing environment and loading rate on intervertebral disc compressive mechanics: an assessment of repeatability at three different laboratories10.1002/jsp2.1110 ↗
27. New in vivo measurements of pressures in the intervertebral disc in daily life10.1097/00007632-199904150-00005 ↗
28. SciPy 1.0: fundamental algorithms for scientific computing in Python10.1038/s41592-019-0686-2 ↗
29. Feature engineering & selection for explainable models: a second course for data scientists
30. Multiphoton imaging and raman spectroscopy of the bovine vertebral endplate10.1039/D1AN00702E ↗
31. Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns10.1016/j.actbio.2019.05.021 ↗
32. Gaining insight into the deformation of Achilles tendon entheses in mice10.1002/adem.202100085 ↗
33. A quality optimization approach to image Achilles tendon microstructure by phase-contrast enhanced synchrotron micro-tomography10.1038/s41598-021-96589-w ↗
34. Phase-contrast enhanced synchrotron micro-tomography of human meniscus tissue10.1016/j.joca.2022.06.003 ↗
35. Image quality and scan time optimisation for in situ phase contrast x-ray tomography of the intervertebral disc10.1016/j.jmbbm.2022.105579 ↗
36. TomoGAN: low-dose synchrotron x-ray tomography with generative adversarial networks: discussion10.1364/JOSAA.375595 ↗
37. Sparse2Noise: low-dose synchrotron X-ray tomography without high-quality reference data10.1016/j.compbiomed.2023.107473 ↗