Wide-band multifrequency MR elastography with a fractional viscoelastic model and nonlinear inversion for enhanced viscoelastic parameter mapping
Source abstract
Abstract
ABSTRACT Magnetic resonance elastography (MRE) typically relies on external vibrations, potentially missing diagnostically relevant low-frequency responses. This study presents a wide-band multifrequency MRE framework that combines intrinsic cardiac motion (≈1 Hz) with conventional 30–60 Hz actuation and reconstructs tissue mechanics with a three-parameter Kelvin-Voigt fractional-derivative (KVFD) model. Subzone nonlinear inversion estimates the baseline stiffness ( ), fractional exponent ( ), and reference frequency ( ) parameters from which frequency-dependent storage ( ), loss ( ), and magnitude ( ) shear moduli are derived. Robustness was verified in COMSOL models containing three stiff inclusions; even with 5% Gaussian noise, was recovered with 12% accuracy and and with 5 % accuracy, while spatial contrast was preserved. Tofu–polyvinyl alcohol (PVA) phantom tests produced two-fold contrast and clear and differentiation between poroelastic tofu and stiff PVA, confirming sensitivity to both stiffness and dispersion. In-vivo , intrinsic–extrinsic MRE was performed in seven patients with hepatic metastasis. Across tumors, the mean contrast-to-noise ratios were 1.30 ( ), 1.10 ( ) and 1.65 ( ), comparable to clinical T2-weighted contrast (∼1.8). A representative colorectal metastasis with a necrotic core showed low and but elevated and centrally, mirroring established MRE signatures of necrosis. Sensitivity analysis demonstrated < 5 % parameter drift for ±30 % initial-value perturbations and a 115 % error increase when the 1 Hz data point was omitted, underscoring the value of the low-frequency anchor. Overall, integrating low-frequency intrinsic motion with KVFD modeling yields stable, spatially resolved biomarkers that capture frequency-dependent behavior invisible to conventional high-frequency MRE, advancing lesion detection and characterization. Statement of Significance Magnetic resonance elastography (MRE) typically probes a narrow high-frequency band (30–60 Hz), missing diagnostically rich low-frequency behavior. We present a wide-band, multifrequency MRE framework that fuses intrinsic cardiac motion (∼1 Hz) with conventional external actuation and reconstructs viscoelasticity using a three-parameter Kelvin–Voigt fractional derivative (KVFD) model. The approach yields interpretable parameters, (baseline stiffness), (power-law dispersion), and (transition frequency), and corresponding frequency-dependent moduli ( , , ). Validation across COMSOL simulations, tofu–PVA phantoms, and in-vivo liver metastasis shows robust convergence under noise, stable parameter recovery, and lesion contrast comparable to clinical MRI, while revealing dispersion not captured by standard MRE. This work expands MRE’s mechanical bandwidth and delivers spatially resolved biomarkers relevant to oncology and to engineered biomaterials whose function depends on frequency-dependent mechanics.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Ultrasound Imaging and Elastography · Coronary Interventions and Diagnostics · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (93)
Show source-provided references
1. MR elastography: principles, guidelines, and terminology10.1002/mrm.28627 ↗
2. Initial in vivo experience with steady-state subzone-based MR elastography of the human breast10.1002/jmri.10232 ↗
3. Viscoelastic shear properties of in vivo breast lesions measured by MR elastography10.1016/j.mri.2004.11.060 ↗
4. MR elastography of breast cancer: preliminary results10.2214/ajr.178.6.1781411 ↗
5. MR elastography of the liver: preliminary results10.1148/radiol.2402050606 ↗
6. MR elastography of liver tumors: preliminary results10.2214/AJR.07.3123 ↗
7. Magnetic resonance elastography of the kidneys: feasibility and reproducibility in young healthy adults10.1002/jmri.22670 ↗
8. Magnetic resonance imaging of the fibrotic kidney10.1681/ASN.2016101089 ↗
9. Magnetic resonance elastography resolving all gross anatomical segments of the kidney during controlled hydration10.3389/fphys.2024.1327407 ↗
10. Magnetic resonance elastography of skeletal muscle10.1002/1522-2586(200102)13:2<269::AID-JMRI1039>3.0.CO;2-1 ↗
11. Evaluation of healthy and diseased muscle with magnetic resonance elastography10.1053/apmr.2002.35472 ↗
12. Real-time MR elastography for viscoelasticity quantification in skeletal muscle during dynamic exercises10.1002/mrm.28095 ↗
13. Magnetic resonance elastography of skeletal muscle deep tissue injury10.1002/nbm.4087 ↗
14. Individual muscle force estimation in the Human forearm using multi-muscle MR elastography (MM-MRE)10.1109/TBME.2023.3283185 ↗
15. Imaging the shear modulus of the heel fat pads10.1016/j.clinbiomech.2004.11.010 ↗
16. Magnetic resonance elastography of the plantar fat pads: preliminary study in diabetic patients and asymptomatic volunteers10.1097/00004728-200603000-00031 ↗
17. MR elastography of the human heart: noninvasive assessment of myocardial elasticity changes by shear wave amplitude variations10.1002/mrm.21878 ↗
18. MR elastography as a method for the assessment of myocardial stiffness: comparison with an established pressure–volume model in a left ventricular model of the heart10.1002/mrm.21991 ↗
19. Cardiac magnetic resonance elastography: toward the diagnosis of abnormal myocardial relaxation10.1097/RLI.0b013e3181ec4b63 ↗
20. Shear wave cardiovascular MR elastography using intrinsic cardiac motion for transducer-free non-invasive evaluation of myocardial shear wave velocity10.1038/s41598-020-79231-z ↗
21. Brain mechanical property measurement using MRE with intrinsic activation10.1088/0031-9155/57/22/7275 ↗
22. Magnetic resonance elastography of the brain10.1016/j.neuroimage.2007.08.030 ↗
23. In vivo viscoelastic properties of the brain in normal pressure hydrocephalus10.1002/nbm.1602 ↗
24. Magnetic resonance elastography of the brain using multishot spiral readouts with self-navigated motion correction10.1002/mrm.24473 ↗
25. Magnetic resonance elastography from fundamental soft-tissue mechanics to diagnostic imaging10.1038/s42254-022-00543-2 ↗
26. Tomoelastography of the prostate using multifrequency MR elastography and externally placed pressurized-air drivers10.1002/mrm.26769 ↗
27. A novel magnetic resonance elastography transducer concept based on a rotational eccentric mass: preliminary experiences with the gravitational transducer10.1088/1361-6560/aaf9f8 ↗
28. Magnetic resonance elastography of the liver: everything you need to know to get started
29. Brain palpation from physiological vibrations using MRI10.1073/pnas.1509895112 ↗
30. Suitability of poroelastic and viscoelastic mechanical models for high and low frequency MR elastography10.1118/1.4905048 ↗
31. Superviscous properties of the in vivo brain at large scales10.1016/j.actbio.2020.12.027 ↗
32. MR elastography for classification of focal liver lesions using viscoelastic parameters: a pilot study based on intrinsic and extrinsic activations
33. Local wavelength estimation for magnetic resonance elastography
34. Local multiscale frequency and bandwidth estimation
35. Curl-based finite element reconstruction of the shear modulus without assuming local homogeneity: time harmonic case10.1109/TMI.2013.2276060 ↗
36. Tomoelastography by multifrequency wave number recovery from time-harmonic propagating shear waves10.1016/j.media.2016.01.001 ↗
37. An overlapping subzone technique for MR-based elastic property reconstruction10.1002/(SICI)1522-2594(199910)42:4<779::AID-MRM21>3.0.CO;2-Z ↗
38. Three-dimensional subzone-based reconstruction algorithm for MR elastography10.1002/mrm.1111 ↗
39. Contrast detection in fluid-saturated media with magnetic resonance poroelastography10.1118/1.3443563 ↗
40. An octahedral shear strain-based measure of SNR for 3D MR elastography10.1088/0031-9155/56/13/N02 ↗
41. Spatially-resolved hydraulic conductivity estimation via poroelastic magnetic resonance elastography10.1109/TMI.2014.2311456 ↗
42. Including spatial information in nonlinear inversion MR elastography using soft prior regularization10.1109/TMI.2013.2268978 ↗
43. Gradient-based optimization for poroelastic and viscoelastic MR elastography10.1109/TMI.2016.2604568 ↗
44. A numerical framework for interstitial fluid pressure imaging in poroelastic MRE10.1371/journal.pone.0178521 ↗
45. A constrained modulus reconstruction technique for breast cancer assessment10.1109/42.952726 ↗
46. Viscoelastic properties of soft gels: comparison of magnetic resonance elastography and dynamic shear testing in the shear wave regime10.1088/0031-9155/56/19/014 ↗
47. Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: a study of brain and liver viscoelasticity10.1088/0031-9155/52/24/006 ↗
48. Selective spectral displacement projection for multifrequency MRE10.1088/0031-9155/58/16/5771 ↗
49. A compact 0.5 T MR elastography device and its application for studying viscoelasticity changes in biological tissues during progressive formalin fixation10.1002/mrm.26659 ↗
50. Structure-sensitive elastography: on the viscoelastic powerlaw behavior of in vivo human tissue in health and disease10.1039/c3sm50552a ↗
51. Viscoelastic characterization of in vitro canine tissue10.1088/0031-9155/49/18/002 ↗
52. Fractional kelvin-voight model for liver tissue in the frequency and time domain
53. Modeling ramp-hold indentation measurements based on Kelvin–Voigt fractional derivative model10.1088/1361-6501/aa9daf ↗
54. Quantitative characterization of viscoelastic properties of human prostate correlated with histology10.1016/j.ultrasmedbio.2007.11.024 ↗
55. Congruence of imaging estimators and mechanical measurements of viscoelastic properties of soft tissues10.1016/j.ultrasmedbio.2007.04.012 ↗
56. Comprehensive experimental assessments of rheological models’ performance in elastography of soft tissues10.1016/j.actbio.2022.04.047 ↗
57. Wave simulation in biologic media based on the Kelvin-Voigt fractional-derivative stress-strain relation10.1016/j.ultrasmedbio.2011.03.009 ↗
58. Fractional calculus in viscoelasticity: an experimental study10.1016/j.cnsns.2009.05.004 ↗
59. Verification of local Kramers–Kronig relations for complex modulus by means of fractional derivative model10.1006/jsvi.1999.2495 ↗
60. High-resolution magnetic resonance elastography reveals differences in subcortical gray matter viscoelasticity between young and healthy older adults10.1016/j.neurobiolaging.2018.01.010 ↗
61. A. Baradaran Najar, G. Gilbert, E. Karam, A. Volniansky, A. Fohlen, M. Barat, E. Montagnon, H. Castel, J.M. Giard, B.N. Nguyen, MR elastography for classification of focal liver lesions using viscoelastic parameters: a pilot study based on intrinsic and extrinsic activations, J. Magn. Reson. Imaging.
62. Elasticity reconstruction from experimental MR displacement data: initial experience with an overlapping subzone finite element inversion process10.1118/1.598861 ↗
63. An octahedral shear strain-based measure of SNR for 3D MR elastography10.1088/0031-9155/56/13/N02 ↗
64. Multiresolution MR elastography using nonlinear inversion10.1118/1.4754649 ↗
65. MR elastography at 1 hz of gelatin phantoms using 3D or 4D acquisition10.1016/j.jmr.2018.08.012 ↗
66. Viscoelastic properties of liver measured by oscillatory rheometry and multifrequency magnetic resonance elastography
67. Measuring viscoelastic parameters in Magnetic Resonance elastography: a comparison at high and low magnetic field intensity10.1016/j.jmbbm.2021.104587 ↗
68. Rapid MR elastography of the liver for subsecond stiffness sampling10.1002/mrm.29859 ↗
69. The feasibility of using elastography for imaging the Poisson's ratio in porous media10.1016/j.ultrasmedbio.2003.10.022 ↗
70. A method for generating permeability elastograms and Poisson’s ratio time-constant elastograms10.1016/j.ultrasmedbio.2005.02.004 ↗
71. Tofu as a tissue-mimicking material10.1016/S0301-5629(01)00424-0 ↗
72. Determination of mechanical and hydraulic properties of PVA hydrogels10.1016/j.msec.2014.11.034 ↗
73. Design of a patient-specific respiratory-motion-simulating platform for in vitro 4D flow MRI10.1007/s10439-022-03117-6 ↗
74. Design of a low-cost, self-adaptive and MRI-compatible cardiac gating system10.1109/TBME.2023.3280348 ↗
75. Enhancing liver nodule visibility and diagnostic classification using ultrasound local attenuation coefficient slope imaging10.1016/j.ultrasmedbio.2025.01.007 ↗
76. Necro-inflammatory activity grading in chronic viral hepatitis with three-dimensional multifrequency MR elastography10.1038/s41598-021-98726-x ↗
77. Rapid acquisition of multifrequency, multislice and multidirectional MR elastography data with a fractionally encoded gradient echo sequence10.1002/nbm.2958 ↗
78. MR elastography of liver: current status and future perspectives10.1007/s00261-020-02656-7 ↗
79. General guidelines for the performance of viscoelastic property identification in elastography: a Monte-Carlo analysis from a closed-form solution10.1002/cnm.3741 ↗
80. Viscoelastic characterization of phantoms for ultrasound elastography created using low-and high-viscosity poly (vinyl alcohol) with ethylene glycol as the cryoprotectant
81. Magnetic resonance poroelastography: an algorithm for estimating the mechanical properties of fluid-saturated soft tissues10.1109/TMI.2009.2035309 ↗
82. Changes in tissue fluidity predict tumor aggressiveness in vivo10.1002/advs.202303523 ↗
83. Tomoelastography distinguishes noninvasively between benign and malignant liver lesions10.1158/0008-5472.CAN-19-2150 ↗
84. Wideband MRE and static mechanical indentation of human liver specimen: sensitivity of viscoelastic constants to the alteration of tissue structure in hepatic fibrosis10.1016/j.jbiomech.2014.02.034 ↗
85. Fractal network dimension and viscoelastic powerlaw behavior: I. A modeling approach based on a coarse-graining procedure combined with shear oscillatory rheometry10.1088/0031-9155/57/12/4023 ↗
86. Making sense of scattering: seeing microstructure through shear waves10.1126/sciadv.adp3363 ↗
87. In vivo time-harmonic multifrequency elastography of the human liver10.1088/0031-9155/59/7/1641 ↗
88. Viscoelasticity-based staging of hepatic fibrosis with multifrequency MR elastography10.1148/radiol.10092489 ↗
89. Wide-range dynamic magnetic resonance elastography10.1016/j.jbiomech.2010.12.031 ↗
90. Value of tumor stiffness measured with MR elastography for assessment of response of hepatocellular carcinoma to locoregional therapy10.1007/s00261-017-1066-y ↗
91. MR elastography of brain tumors
92. Decreased tissue stiffness in glioblastoma by MR elastography is associated with increased cerebral blood flow
93. https://BioRender.com.