Transcatheter aortic valve replacement (TAVR) has emerged as an effective therapy for inoperable patients with severe aortic stenosis (AS). However, calcification-induced limited durability restricts its application. Fish swim bladders (FSB), which are resistant to calcific degeneration, offer a viable solution to this challenge. In this study, we developed a new TAVR device using FSB as the valve leaflet. Furthermore, the in vitro durability, in vivo performance, and size selection of this TAVR device were assessed by an experimental study and finite element analysis. A self-expandable TAVR device was fabricated by suturing the FSB films into a 23 mm nitinol alloy frame. Further, hemodynamic performance, such as effective orifice area, transvalvular pressure difference and regurgitant fraction, the durability was tested by the pulsatile flow test and accelerated fatigue test, according to the ISO 5840-3. The effect of release size on hydrodynamic performance was also investigated. Finally, the in vivo performance of the TAVR device were examined using a porcine implantation model. The results showed that the strength of the FSB films satisfied the requirements for valve leaflets. The hemodynamic performance of the FSB TAVR device met the requirements of ISO 5840-3 standards. After 400 million cycles, the FSB showed no fiber loss, torn, perforation, or other valve failure phenomena. In porcine models, the devices were well-positioned, functioned well with no stenosis immediately after the operation. Collectively, we successfully developed a TAVR device with FSB as valve leaflets that exhibited good fatigue resistance. STATEMENT OF SIGNIFICANCE: The source of material for the leaflets of commercialized biological heart valves (BHVs) is mainly bovine pericardium, but this material suffers the following problems: large and uneven thickness of the material, the presence of α-Gal and Neu5Gc antigens, and the susceptibility to structural valve degradation (SVD). New material for BHVs leaflets is rarely reported. In this study, we prepared a transcatheter aortic valve (TAV) and performed long-term in vitro and short-term in vivo studies using fish swim bladder (FSB) as the leaflets. The study confirmed that FSB TAV device can complete 400 million fatigue tests and maintain the good morphology of the leaflets, and that it still maintains good functionality after a certain amount of compression, indicating that FSB is a promising material for leaflets.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Aortic Disease and Treatment Approaches · Infective Endocarditis Diagnosis and Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. SURTAVI trial investigators, self-expanding transcatheter vs surgical aortic valve replacement in intermediate-risk patients: 5-year outcomes of the surtavi randomized clinical trial10.1001/jamacardio.2022.2695 ↗
2. Low risk trial investigators., 3-year outcomes after transcatheter or surgical aortic valve replacement in low-risk patients with aortic stenosis10.1016/j.jacc.2023.02.017 ↗
3. Evolut low risk trial investigators, transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients10.1056/NEJMoa1816885 ↗
4. A systematic review on durability and structural valve deterioration in TAVR and surgical AVR10.1080/00015385.2020.1858250 ↗
5. Breimer ME, Gal/non-Gal antigens in pig tissues and human non-Gal antibodies in the GalT-KO era10.1111/j.1399-3089.2011.00644.x ↗
6. Swim bladder as a novel biomaterial for cardiovascular materials with anti-calcification properties
7. Immunogenicity assessment of swim bladder-derived biomaterials10.1039/D2BM01419J ↗
8. Preparation and characterization of a novel acellular swim bladder as dura mater substitute10.1080/01616412.2018.1550139 ↗
9. Decellularized fish swim bladder patch loaded with mesenchymal stem cells inhibits neointimal hyperplasia10.1002/jbm.b.35172 ↗
10. The application of tissue-engineered fish swim bladder vascular graft10.1038/s42003-021-02696-9 ↗
11. Swim bladder as an alternative biomaterial for bioprosthetic valves10.1039/D1BM01296G ↗
12. Computational modeling for surgical reconstruction of aortic valve by using autologous pericardium10.1109/ACCESS.2020.2997605 ↗
13. Prediction of patient-specific post-operative outcomes of TAVI procedure: The impact of the positioning strategy on valve performance10.1016/j.jbiomech.2015.10.048 ↗
14. Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root10.1080/10255842.2015.1058928 ↗
15. Bayesian inference of constitutive model parameters from uncertain uniaxial experiments on murine tendons10.1016/j.jmbbm.2019.04.037 ↗
16. Fluid-structure interaction study of transcatheter aortic valve dynamics using smoothed particle hydrodynamics10.1007/s13239-016-0285-7 ↗
17. Bioprosthetic heart valves: modes of failure10.1111/j.1365-2559.2008.03190.x ↗
18. Valve academic research consortium 3: updated endpoint definitions for aortic valve clinical research10.1093/eurheartj/ehaa799 ↗
19. Xenograft bioprosthetic heart valves: past, present and future10.1016/j.ijsu.2015.07.009 ↗
20. Gal knockout pig pericardium: new source of material for heart valve bioprostheses10.1016/j.healun.2009.10.007 ↗
21. The role of antibody responses against glycans in bioprosthetic heart valve calcification and deterioration10.1038/s41591-022-01682-w ↗
22. Potential impact of the non-human sialic acid N-glycolylneuraminic acid on transplant rejection risk10.1111/j.1399-3089.2011.00622.x ↗
23. Valve durability after transcatheter aortic valve implantation10.21037/jtd.2018.07.38 ↗
24. Collagen fibre-mediated mechanical damage increases calcification of bovine pericardium for use in bioprosthetic heart valves10.1016/j.actbio.2021.04.046 ↗
25. Aortic leaflet stresses are substantially lower using pulmonary visceral pleura than pericardial tissue
26. Effects of hemodynamic conditions and valve sizing on leaflet bending stress in self-expanding transcatheter aortic valve: an in vitro study10.1111/aor.13654 ↗