Adhesion and cohesion in structures containing suspended microscopic polymeric films
Source abstract
Abstract
This paper presents a novel technique for the characterization of adhesion and cohesion in suspended micro-scale polymeric films. The technique involves push-out testing with probes that are fabricated using focused ion beam techniques. The underlying stresses associated with different probe tip sizes were computed using a finite element model. The critical force for failure of the film substrate interface is used to evaluate adhesion, while the critical force for penetration of the film determines cohesion. When testing a standard material, polycarbonate, a shear strength of approximately 70 MPa was calculated using the Mohr-Coulomb theory. This value was shown to be in agreement with the results in the literature. The technique was also applied to the measurement of adhesion and cohesion in a model drug-eluting stent (the Nevo™ Sirolimus Eluting Coronary Stent) containing suspended microscopic polymeric films in metallic Co-Cr alloy reservoirs. The cohesive strength of the formulation was found to be comparable with that of plastics such as those produced by reaction injection molding and high-density polyethylene.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Force Microscopy Techniques and Applications · Corrosion Behavior and Inhibition · Integrated Circuits and Semiconductor Failure Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Drug-eluting stents in vascular intervention10.1016/S0140-6736(03)12275-1 ↗
2. Vodnick D, Nay R. Interfacial adhesion of viscoelastic coatings on medical stents, Hysitron application note. Eden Prairie, MN: Hysitron; 2011
3. 1998
4. 2001
5. Estimation of the strength of adhesion between a thermoresponsive polymer coatinig and nitinol wire10.1007/s10856-007-3274-4 ↗
6. Tang F, Ding N, Pacetti S. Nano-scratch adhesion evaluation of the XIENCE V™ drug eluting stent coating. In: Society for Biomaterials Annual Meeting; 2008.
7. An investigation of adhesion in drug-eluting stent layers10.1002/jbm.a.31860 ↗
8. Adhesion and interfacial fracture toughness between hard and soft materials10.1063/1.3021350 ↗
9. Adhesion and interfacial fracture in drug-eluting stents10.1557/JMR.2010.0097 ↗
10. ASTM. Standard D732-10: Standard Test Method for shear strength of plastics by punch tool. West Conshohocken, PA: ASTM International; 2010
11. Essai sur une application des regles des maximis et minimis a quelquels problemesde statique relatifs, a la architecture
12. Mechanical properties of tungsten and steel fiber reinforced Zr41.25Ti13.75Cu12.5Ni10Be22.5 metallic glass matrix composites10.1016/S1359-6454(98)00275-4 ↗
13. Fatigue and life prediction for cobalt–chromium stents: a fracture mechanics analysis10.1016/j.biomaterials.2005.10.012 ↗
14. Synthesis and characterization of elastic PLGA/PCL/PLGA tri-block copolymers10.1163/156856202320813864 ↗
15. Interracial debonding and fiber pull-out stresses of fiber-reinforced composites IV – sliding due to residual stresses10.1016/0921-5093(91)90243-G ↗