Is the early fragmentation of intrauterine devices caused by stress corrosion cracking?
Source abstract
Abstract
Copper wire is the main component of a type of intrauterine device used as a contraceptive. Its contraceptive effect is attributed to the copper ions released as a result of the dissolution of copper in the uterus. Even though 10-year intrauterine device life is estimated on the basis of the dissolution rate of copper measured in vivo and in vitro, some cases of breakdown or fragmentation of the copper wire after short periods of insertion (2-3 months) have been reported. Due to the possible existence of residual stresses as a consequence of the manufacturing process, stress corrosion cracking has been previously proposed as an explanation for the early ruptures. In the present work, the susceptibility of copper wires to stress corrosion cracking in simulated uterine fluids was investigated. Results indicate that early ruptures should not be attributed to stress corrosion cracking. They could be explained by considering the increase in corrosion rate under certain conditions (pH decrease during infections; changes in the concentration of organic components along the menstrual cycle; etc.) that reduces the wire section leading to the rupture of the specimen by overloading.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Trace Elements in Health · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Copper corrosion-simulated uterine solutions10.1016/S0010-7824(00)00124-4 ↗
2. Corrosion of copper in utero10.1016/S0015-0282(16)43397-2 ↗
3. Degradation of the copper-releasing intrauterine contraceptive device and its significance10.1111/j.1471-0528.1984.tb05903.x ↗
4. Duration of use of copper releasing IUD and the incidence of copper wire breakage10.1016/0028-2243(90)90080-K ↗
5. The corrosion behaviour of copper in simulated uterine fluid10.1016/0010-938X(95)00154-C ↗
6. Influence of pH and oxygen on copper corrosion in simulated uterine fluid10.1016/S0142-9612(01)00154-5 ↗
7. Corrosion characteristics of copper-based IUDs10.1108/00035590310463993 ↗
8. Influence of oxygen, albumin and pH on copper dissolution in a simulated uterine fluid10.1080/13625180500131642 ↗
9. Fontana · 1986
10. 1996
11. Stress-corrosion cracking of copper alloys
12. Stress corrosion cracking of copper and silver, specific effect of the metal cations10.1016/j.corsci.2004.05.019 ↗
13. Characterization of copper corrosion products originated in simulated uterine fluids and on packaged intrauterine devices10.1023/A:1011288701499 ↗
14. Human uterine fluid, examined in undiluted samples for osmolarity and the concentrations of inorganic ions, albumin, glucose, and urea10.1016/0002-9378(84)90466-6 ↗
15. Characterizationi of copper in uterine fluids of patients who use the copper T-380A intrauterine device10.1016/S0009-8981(03)00124-4 ↗
16. Characteristics of copper corrosion in simulated uterine fluid in the presence of protein10.1023/A:1006793231274 ↗
17. Electrochemical behaviour of copper/LDPE composites in the simulated uterine solution10.1016/j.electacta.2006.02.034 ↗
18. The influence of halide ions at submonolayer levels on the formation of oxide layer and electrodissolution of copper in neutral solutions10.1016/0013-4686(88)85008-4 ↗
19. Kinetics of passivation and pitting corrosion of polycrystalline copper in borate buffer solutions containing sodium chloride10.1016/0013-4686(85)80012-8 ↗
20. The effect of purine on the corrosion of copper in chloride solutions10.1016/j.corsci.2006.06.022 ↗
21. Investigation of inhibition of 2-mercaptobenzoxazole for copper corrosion10.1016/S0013-4686(00)00385-6 ↗
22. Trace metal speciation measurements in waters by the liquid binding phase DGT device10.1016/j.talanta.2005.03.018 ↗
23. Investigations of different carbohydrate anomers in copper(II) complexes with d-glucose, d-fructuose, and S-galactose by Raman and EPR spectroscopy10.1016/j.carres.2005.08.002 ↗
24. Dissociation behavior of Cu(urea)+ complexes generated by electrospray ionization10.1016/S1387-3806(02)00751-0 ↗
25. Release of copper-bearing intrauterine contraceptive device10.1136/bmj.2.6082.288 ↗
26. Multi-metal binding site of serum albumin10.1016/S0162-0134(98)00010-5 ↗
27. Reversible precipitation of bovine serum albumin by metal ions and synthesis, structure and reactivity of new tetrathiometallate chelating agents10.1016/j.jinorgbio.2007.07.015 ↗