journal article·2012-09Open access

A new dextran-graft-polybutylmethacrylate copolymer coated on 316L metallic stents enhances endothelial cell coverage

S.M. Derkaoui, A. Labbé, P. Chevallier, S. Holvoet, C. Roques, T. Avramoglou, D. Mantovani, D. Letourneur

Acta Biomaterialia· Volume 8· Issue 9

Abstract

Amphiphilic copolymers based on the copolymerization of hydrophilic and hydrophobic moieties offer versatility in various biomedical material applications. Here, a new biocompatible copolymer of dextran-graft-polybutylmethacrylate is synthesized for the coating of metallic endovascular stents. Coating of metallic surfaces is performed and analyzed by X-ray photoelectron spectroscopy, attenuated total reflection Fourier transform infrared spectroscopy, contact angle measurement, atomic force microscopy and scanning electron microscopy before and after deformation corresponding to stent deployment by a balloon catheter. In the conditions described here, the resulting coating is smooth and uniform with neither cracks nor detachment after stent expansion. Interestingly, surfaces coated with the copolymer greatly improve in vitro adhesion and growth of endothelial cells. This copolymer provides new opportunities for implanted biomaterials.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Polymer Surface Interaction Studies · Electrospun Nanofibers in Biomedical Applications · Nanoparticle-Based Drug Delivery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Snake venom disintegrin, saxatilin, inhibits platelet aggregation, human umbilical vein endothelial cell proliferation, and smooth muscle cell migration10.1016/S0049-3848(01)00416-9 ↗
2. Differences of platelet adhesion and thrombus activation on amorphous silicon carbide, magnesium alloy, stainless steel, and cobalt chromium stent surfaces
3. Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications10.1007/s10856-006-9228-4 ↗
4. Self-assembled monolayers with different terminating groups as model substrates for cell adhesion studies10.1016/j.biomaterials.2003.09.069 ↗
5. Enhancement of the growth of human endothelial cells by surface roughness at nanometer scale10.1016/S0142-9612(03)00361-2 ↗
6. Coronary stents: a materials perspective10.1016/j.biomaterials.2006.11.042 ↗
7. Role of polymers in improving the results of stenting in coronary arteries10.1016/0142-9612(96)86738-X ↗
8. Biocompatibility aspects of new stent technology10.1016/S0735-1097(98)00289-7 ↗
9. Growth inhibition of cultured smooth muscle cells by corrosion products of 316L stainless steel wire10.1002/1097-4636(200111)57:2<200::AID-JBM1159>3.0.CO;2-5 ↗
10. Tissue reaction around metal implants observed by X-ray scanning analytical microscopy10.1016/S0142-9612(00)00230-1 ↗
11. The effect of high-density-lipoprotein on thrombus formation on and endothelial cell attachement to biomaterial surfaces10.1016/j.biomaterials.2005.12.025 ↗
12. Culture of human cells and synthesis of extracellular matrix on materials compatible with direct analysis by mass spectrometry10.1039/b914539g ↗
13. Controlled biological response on blends of a phosphorylcholine-based copolymer with poly(butyl methacrylate)10.1016/S0142-9612(03)00272-2 ↗
14. Hydrophilic surface modification of metallic endoluminal stents10.1016/S0741-5214(95)70148-6 ↗
15. In vitro biocompatibility of biodegradable dextran-based hydrogels tested with human fibroblasts10.1016/S0142-9612(00)00266-0 ↗
16. In vitro and in vivo biocompatibility of dextran dialdehyde cross-linked gelatin hydrogel films10.1016/S0142-9612(98)00049-0 ↗
17. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization10.1056/NEJMoa012843 ↗
18. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study10.1161/01.CIR.103.2.192 ↗
19. Synthesis and characterization of a new polysaccharide-graft-polymethacrylate copolymer for three-dimensional hybrid hydrogels10.1021/bm800470z ↗
20. Study of the adhesion of thin plasma fluorocarbon coatings resisting plastic deformation for stent applications10.1088/0022-3727/41/4/045310 ↗
21. A predictive study of the mechanical behaviour of coronary stents by computer modelling10.1016/j.medengphy.2004.08.012 ↗
22. Degradable metallic biomaterials: design and development of Fe–Mn alloys for stents10.1002/jbm.a.32224 ↗
23. Characterization of film failures by bismuth electrodeposition—application to thin deformed fluorocarbon films for stent applications10.1016/j.electacta.2009.09.079 ↗
24. X-ray photoelectron emission microscopy and time-of-flight secondary ion mass spectrometry analysis of ultrathin fluoropolymer coatings for stent applications10.1021/la8002788 ↗
25. WSXM: a software for scanning probe microscopy and a tool for nanotechnology10.1063/1.2432410 ↗
26. Leukotriene receptor antagonism and the prevention of extracellular matrix degradation during atherosclerosis and in-stent stenosis10.1161/ATVBAHA.108.181750 ↗
27. Films of dextran-graft-polybutylmethacrylate to enhance endothelialization of materials10.1016/j.actbio.2010.03.043 ↗
28. Nonthermal plasma technology as a versatile strategy for polymeric biomaterials surface modification: a review10.1021/bm900186s ↗