Macroporous-channel hollow microneedles enable vacuum-free interstitial fluid sampling and on-patch sensing
Source abstract
Abstract
Microneedle (MN) devices that sample skin interstitial fluid (ISF) without an external vacuum offer strong point-of-care potential, but are often limited by insufficient extraction flux and fabrication complexity. Here, we present macroporous-channel hollow microneedles (MPCHMNs) that integrate three features in a single photopatterning step: a rigid polymer shell for mechanical support, an interconnected micrometer-scale porous network formed by porogen removal, and an axially enriched macroporous conduit formed by a percolated chain of interconnected spherical cavities. This architecture establishes multiscale capillarity that drives vacuum-free ISF sampling. When coupled to a paper-wick collector or an on-patch sensing module, the interface enables rapid wicking and on-device readout without pumps or tubing. In ex vivo skin models and in vivo rat studies, MPCHMNs achieved ISF yields and start-up times that were comparable to those of negative-pressure collectors under matched conditions, while maintaining agreement between ISF and paired blood measurements for representative electrolytes and metabolites. Electrochemical modules quantified potassium (potentiometry) and glucose (amperometry), and a colorimetric panel reported glucose, acetoacetate, and creatinine. Viewed as a capillarity-driven transducer, MPCHMNs link structure to function and reduce system complexity. The resulting disposable, compact format supports vacuum-free ISF sampling and on-patch analysis, offering a practical path toward minimally invasive, near-patient monitoring. STATEMENT OF SIGNIFICANCE: We introduce macroporous-channel hollow microneedles that combine a rigid polymer shell, an interconnected macroporous network, and an axial lumen created in a single photopatterning step. This architecture establishes multiscale capillarity that supports vacuum-free dermal interstitial-fluid sampling and enables on-patch electrochemical or colorimetric readout without pumps or tubing. Across ex vivo skin models and in vivo rats, sampling yields and analytical agreement with paired blood measurements were comparable to negative-pressure collectors under matched conditions, while reducing system complexity. Treating the microneedle as a capillarity-driven transducer links structure to function and offers a practical route to compact, disposable devices for minimally invasive, near-patient monitoring.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advancements in Transdermal Drug Delivery · Advanced Drug Delivery Systems · Microbial Inactivation Methods
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. Point-of-care testing: state-of-the art and perspectives10.1515/cclm-2024-0675 ↗
2. Microneedle sensors for point-of-care diagnostics10.4028/b-7TThNX ↗
3. Recent developments and future perspectives of microfluidics and smart technologies in wearable devices10.1039/D4LC00089G ↗
4. Turbulence-enhanced microneedle immunoassay platform (TMIP) for high-precision biomarker detection from skin interstitial fluid10.1016/j.bios.2025.117480 ↗
5. Hydrogel-forming microneedles and applications in interstitial fluid diagnostic devices10.1002/adhm.202401782 ↗
6. Sensing patches for biomarker identification in skin-derived biofluids10.1016/j.bios.2024.116326 ↗
7. Opportunities and challenges in the diagnostic utility of dermal interstitial fluid10.1038/s41551-022-00998-9 ↗
8. Recent progress in microneedles-mediated diagnosis, therapy, and theranostic systems
9. In Vivo transdermal multi-ion monitoring with a potentiometric microneedle-based sensor patch10.1021/acssensors.2c01907 ↗
10. Microneedle coupled epidermal sensor for multiplexed electrochemical detection of kidney disease biomarkers10.1016/j.bios.2023.115506 ↗
11. An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid10.1038/s41551-022-00887-1 ↗
12. A conductive hydrogel-based microneedle platform for real-time pH measurement in live animals10.1002/smll.202200201 ↗
13. Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid10.1038/s41551-020-00672-y ↗
14. Sampling interstitial fluid from human skin using a microneedle patch10.1126/scitranslmed.aaw0285 ↗
15. Integrated electrochemical aptamer biosensing and colorimetric pH monitoring via Hydrogel microneedle assays for assessing antibiotic treatment10.1002/advs.202309027 ↗
16. Wearable aptalyzer integrates microneedle and electrochemical sensing for In vivo monitoring of glucose and lactate in live animals
17. A wearable touch-activated device integrated with hollow microneedles for continuous sampling and sensing of dermal interstitial fluid
18. A hydrogel microneedle assay combined with nucleic acid probes for on-site detection of small molecules and proteins10.1002/anie.202301624 ↗
19. A smart lab on a wearable microneedle patch with convolutional neural network-enhanced colorimetry for early warning of syndrome of inappropriate antidiuretic hormone secretion10.1002/agt2.671 ↗
20. Osmosis-powered hydrogel microneedles for microliters of skin interstitial fluid extraction within minutes10.1002/adhm.201901683 ↗
21. Bio-inspired microneedles with hierarchical microchannels for rapid interstitial fluid collection and analysis10.1039/D5LC00145E ↗
22. Microneedle patch for painless intradermal collection of interstitial fluid enabling multianalyte measurement of small molecules, SARS-CoV-2 antibodies, and protein profiling10.1002/adhm.202202564 ↗
23. Bio-informed porous mineral-based composites
24. Microneedles with an anisotropic porous microstructure facilitate the transdermal delivery of small molecules, lipid nanoparticles, and T cells10.1016/j.matt.2025.102038 ↗
25. Preparation of inverse opal adsorbent by water-soluble colloidal crystal template to obtain ultrahigh adsorption capacity for salicylic acid removal from aqueous solution10.1016/j.jhazmat.2019.03.020 ↗
26. Transdermal electroosmotic flow generated by a porous microneedle array patch10.1038/s41467-021-20948-4 ↗
27. Porous microneedle-based electrochemical sensor for potassium and glucose in skin interstitial fluid10.1039/D5AY00915D ↗
28. Electro-responsive silk fibroin microneedles for controlled release of insulin10.1016/j.ijbiomac.2023.124684 ↗
29. From frog integument to human skin: dermatological perspectives from frog skin biology10.1111/brv.12072 ↗
30. Smart microneedle patches for rapid, and painless transdermal insulin delivery10.1039/D0TB01822H ↗
31. Multibioinspired slippery surfaces with wettable bump arrays for droplets pumping10.1073/pnas.1912467116 ↗
32. Inverse opal microneedles arrays for fluorescence enhanced screening skin interstitial fluid biomarkers10.1016/j.nantod.2022.101655 ↗
33. A 3D-printed microneedle extraction system integrated with patterned electrodes for minimally invasive transdermal detection10.1039/D2BM01975B ↗
34. Hollow microneedle microfluidic paper-based chip for biomolecules rapid sampling and detection in interstitial fluid10.1016/j.aca.2023.341101 ↗
35. One-shot fabrication of polymeric hollow microneedles by standard photolithography10.3390/polym13040520 ↗
36. Mechanisms of sampling interstitial fluid from skin using a microneedle patch10.1073/pnas.1716772115 ↗
37. Sliding Microneedle - lateral flow immunoassay strip device for highly sensitive biomarker detection in interstitial fluid10.1016/j.bios.2024.116590 ↗
38. 3D-printed microneedles with open groove channels for liquid extraction10.1002/EXP.20210109 ↗
39. Lucas–Washburn equation-based modeling of capillary-driven flow in porous systems10.1021/acs.langmuir.0c03134 ↗
40. Microscale liquid transport in polycrystalline inverse opals across grain boundaries10.1038/s41598-017-10791-3 ↗
41. Poly(glycidyl methacrylate) as a tunable platform of modifiers for microfluidic devices10.1016/j.reactfunctpolym.2016.01.002 ↗
42. Hydrophobic polymer surfaces and their interactions with blood10.1111/j.1749-6632.1977.tb41781.x ↗
43. Feasibility of interstitial fluid ketone monitoring with microneedles10.3390/metabo12050424 ↗
44. Integrated microfluidic colorimetric patch with auto-framing APP for multiplex temporal detection of ketone bodies in sweat10.1039/D5LC00189G ↗
45. Software integrated personalized biosensing device for serum creatinine detection based on boron doped MXene nanohybrid10.1021/acsbiomaterials.4c01451 ↗
46. Rapid glutathione analysis with SERS microneedles for deep glioblastoma tissue differentiation10.1021/acs.analchem.4c00483 ↗
47. Antioxidant capacity and protective effect of cow placenta extract on D-galactose-induced skin aging in mice10.3390/nu14214659 ↗
48. A new peptide originated from amphibian skin alleviates the ultraviolet B-induced skin photodamage10.1016/j.biopha.2022.112987 ↗
49. Microneedle-based potentiometric sensing system for continuous monitoring of multiple electrolytes in skin interstitial fluids10.1021/acssensors.0c02330 ↗
50. Development of smartphone-controlled and microneedle-based wearable continuous glucose monitoring system for home-care diabetes management10.1021/acssensors.2c02635 ↗
51. Microneedle-coupled epidermal sensors for In-situ-multiplexed ion detection in interstitial fluids
52. A colorimetric dermal tattoo biosensor fabricated by microneedle patch for multiplexed detection of health-related biomarkers10.1002/advs.202103030 ↗
53. Harvesting and manipulating sweat and interstitial fluid in microfluidic devices10.1039/D3LC00874F ↗
54. Lateral flow-based skin patch for rapid detection of protein biomarkers in Human dermal interstitial fluid10.1021/acssensors.4c00956 ↗
55. Microneedle-based sampling of dermal interstitial fluid using a vacuum-assisted skin patch
56. Tanshinone IIA promotes ferroptosis in cutaneous melanoma via STAT1-mediated upregulation of PTGS2 expression10.1016/j.phymed.2025.156702 ↗
57. Label free, electric field mediated ultrasensitive electrochemical point-of-care device for CEA detection10.1038/s41598-021-82580-y ↗
58. Recent advances in batteryless NFC sensors for chemical sensing and biosensing10.3390/bios13080775 ↗
59. Colorimetric microneedle patches for multiplexed transdermal detection of metabolites10.1016/j.bios.2022.114412 ↗