Mitigating adverse effects of Cu-containing intrauterine devices using a highly biocompatible Cu 5Fe alloy
Source abstract
Abstract
Copper-containing intrauterine devices (Cu-IUD) are adopted by worldwide women for contraception with the advantages of long-term effectiveness, reversibility and affordability. However, adverse effects occur in the initial implantation stage of Cu-IUD in uterine because of the burst release of Cu2+. To minimize the burst release, in this study, we designed a series of Cu-Fe alloys with 0.5 wt%, 1 wt% and 5 wt% Fe and also further produced ultrafine grained (UFG) structure for these alloys via equal-channel angular pressing. The microstructures and properties of the coarse grained (CG) Cu, CG Cu-Fe alloys and UFG Cu-Fe alloys were systematically investigated, including grain structure and phase compositions, metallic ions release behavior, electrochemical corrosion performance, and in vitro cytotoxicity. With careful comparison and selection, we chose the CG Cu-5Fe and UFG Cu-5Fe for in vivo tests using rat model, including tissue biocompatibility, in vivo corrosion behavior, and contraceptive effectiveness. Moreover, the corrosion mechanism of the Cu-5Fe alloy and its improved biocompatibility was discussed. Both CG and UFG Cu-5Fe alloys exhibited dramatic suppression of Cu2+ release in simulated uterine fluid for the long-term immersion process. The in vivo tissue compatibility was significantly improved with both CG and UFG Cu-5Fe alloys implanted in the rats' uterine while the high contraceptive efficacy was well maintained. Due to the superior biocompatibility, the CG and UFG Cu-5Fe alloys can be the promising candidate material for Cu-IUD. STATEMENT OF SIGNIFICANCE: A highly biocompatible Cu-Fe alloy was designed and fabricated for Cu-containing intrauterine devices (Cu-IUD). With 5 wt% Fe, the burst release of Cu2+ is inhibited due to the formed galvanic cell of Cu and Fe, resulting in earlier release of Fe3+. As Fe is the most abundant essential trace element of human body, it can mitigate the toxic effects of Cu2+, thus significantly improving both in vitro cell compatibility and in vivo tissue compatibility. More importantly, the Cu-5Fe alloy exhibits 100 % contraceptive efficiency as the CG Cu, but with greatly reduced adverse effects to the uterus tissues. An advanced Cu-IUD can be developed using Cu-Fe alloys.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Orthopaedic implants and arthroplasty · Metallurgy and Material Science
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Long-acting reversible contraception10.1056/NEJMcp1608736 ↗
2. Intrauterine devices and contraceptive implants: overview of options and updates on method use10.1007/s13669-017-0200-8 ↗
3. Hormonal and intrauterine methods for contraception for women aged 25 years and younger
4. Metallic copper as an intrauterine contraceptice adjunct to the "T" device10.1016/0002-9378(69)90302-0 ↗
5. Mechanisms of action of intrauterine devices10.1097/00006254-199612000-00014 ↗
6. Copper-T intrauterine device and levonorgestrel intrauterine system: biological bases of their mechanism of action10.1016/j.contraception.2007.01.020 ↗
7. Acute toxicological effects of copper nanoparticles in vivo10.1016/j.toxlet.2005.10.003 ↗
8. The effect of copper on endometrial receptivity and induction of apoptosis on decidualized human endometrial stromal cells10.1177/1933719117732165 ↗
9. Effect of copper on the preimplantation mouse embryo10.1038/238398a0 ↗
10. Relationship between copper IUD complications and ultrasonographic findings10.1007/s00404-018-4711-y ↗
11. Analysis of the reason of abnormal uterine bleeding induced by copper corrosion of IUD Cu10.12891/ceog3204.2016 ↗
12. Temporal trends of copper-bearing intrauterine device discontinuation: a population-based birth-cohort study of contraceptive use among rural married women in China10.1177/1010539513517259 ↗
13. Investigation of the release behavior of cupric ion for three types of Cu-IUDs and indomethacin for medicated Cu-IUD in simulated uterine fluid10.1016/j.contraception.2007.12.005 ↗
14. Comparison of the release behaviors of cupric ions from metallic copper and a novel composite in simulated body fluid10.1002/jbm.b.30931 ↗
15. Study on a novel copper-containing composite for contraception10.1016/j.contraception.2009.01.002 ↗
16. Release behavior of copper ion in a novel contraceptive composite10.1016/j.contraception.2007.04.010 ↗
17. A porous Cu/LDPE composite for copper-containing intrauterine contraceptive devices10.1016/j.actbio.2011.09.024 ↗
18. Corrosion behavior of copper/LDPE nanocomposites in simulated uterine solution10.1016/j.biomaterials.2004.08.003 ↗
19. Biological evaluation of a novel copper-containing composite for contraception10.1016/j.fertnstert.2010.04.041 ↗
20. Chitosan/alginate multilayer film for controlled release of IDM on Cu/LDPE composite intrauterine devices10.1016/j.colsurfb.2013.03.036 ↗
21. Effective inhibition of the early copper ion burst release with ultra-fine grained copper and single crystal copper for intrauterine device application10.1016/j.actbio.2011.10.018 ↗
22. Corrosion of copper intrauterine devices: review and recent developments10.1515/corrrev-2019-0012 ↗
23. Effective easing of the side effects of copper intrauterine devices using ultra-fine-grained Cu-0.4Mg alloy10.1016/j.actbio.2021.04.037 ↗
24. Feasibility evaluation of a Cu-38 Zn alloy for intrauterine devices: in vitro and in vivo studies10.1016/j.actbio.2021.11.006 ↗
25. Fundamental theory of biodegradable metals—definition, criteria, and design10.1002/adfm.201805402 ↗
26. Emsley · 2011
27. Z.Y.X. Lyu, G. Wang, Biology of Elements (in Chinese), University of Science and Technology of China Press, Hefei, China (2011).
28. Gropper · 2013
29. Preclinical evaluation of a novel sirolimus-eluting iron bioresorbable coronary scaffold in porcine coronary artery at 6 months10.1016/j.jcin.2018.10.020 ↗
30. Effect of copper content and sintering temperature on friction and wear properties of powder-metallurgical Fe-Cu based composites
31. Effective inhibition of the early copper ion burst release by purine adsorption in simulated uterine fluids10.1016/j.electacta.2015.12.093 ↗
32. Copper corrosion-simulated uterine solutions10.1016/S0010-7824(00)00124-4 ↗
33. Is the early fragmentation of intrauterine devices caused by stress corrosion cracking?10.1016/j.actbio.2009.04.033 ↗
34. Influence of pH and oxygen on copper corrosion in simulated uterine fluid10.1016/S0142-9612(01)00154-5 ↗
35. Release of copper and indomethacin from intrauterine devices immersed in simulated uterine fluid10.3109/13625181003782860 ↗
36. One equivalent electrical circuit is applicable to model the interface between the passive surface layer on an orthopaedic alloy and a biosimulating aqueous solution
37. An XPS and AES study of the free corrosion of Cu-, Ni- and Zn-based alloys in synthetic sweat10.1016/S0010-938X(98)00141-3 ↗
38. Studies of CuCl/γ-Al2O3 by XPS, SSIMS AND ISS10.3866/PKU.WHXB19870411 ↗
39. X-ray photoelectron studies on some oxides and hydroxides of cobalt, nickel, and copper10.1021/ac60363a034 ↗
40. Surface characterization and corrosion behavior of 90/10 copper-nickel alloy in marine environment10.3390/ma12111869 ↗
41. Resolving surface chemical states in XPS analysis of first row transition metals, oxides and hydroxides: Cr, Mn, Fe, Co and Ni10.1016/j.apsusc.2010.10.051 ↗
42. The corrosion behaviour of copper in simulated uterine fluid10.1016/0010-938X(95)00154-C ↗
43. Corrosion behavior of copper in a copper bearing intrauterine device in the presence of indomethacin10.1016/S0010-7824(97)00207-2 ↗
44. Corrosion and galvanic compatibility studies of a high-strength copper-nickel alloy10.5006/1.3277305 ↗
45. Impedance and photoelectrochemical study of surface layers on Cu and Cu–10Ni in acetate solution containing benzotriazole10.1016/S0013-4686(98)00367-3 ↗
46. 2-Amino-5-ethyl-1,3,4-thiadiazole as a corrosion inhibitor for copper in 3.0% NaCl solutions10.1016/j.corsci.2006.03.011 ↗
47. Corrosion of copper intrauterine devices: review and recent developments10.1515/corrrev-2019-0012 ↗