journal article·2025-02Open access

Development of hemoglobin microbubbles for acoustic blood oxygen sensing: A study on PEGylation and gas core modification for in vivo applications

Ghazal Rastegar, Bahareh Kianpour, Teja Pathour, Mohammad Musa Salman, Shashank R. Sirsi

Acta Biomaterialia· Volume 193

Abstract

The creation of innovative ultrasound contrast agents (UCAs) with the ability to monitor oxygen levels in real-time holds immense potential for advancing early diagnosis of various medical conditions such as hypoxic/reperfusion injury. In this study, we propose the development of oxygen sensitive UCAs using microbubbles composed of hemoglobin (HbMBs), which can function as sensors for blood oxygen levels. Previously, we performed a study highlighting the initial proof-of-concept efficacy of air-filled HbMBs in detecting oxygenation changes in vitro, offering a promising tool for clinically detecting tissue hypoxia. Nevertheless, a significant drawback of this approach is the potential for immune reactions and toxicity when hemoglobin is outside its natural red blood cell environment. Moreover, in vitro, HbMBs had low stability, with more than 90% decrease in their concentration after 120 minutes. Therefore, careful consideration of the surface properties and the gas core of HbMBs is crucial. Here, we formulated PEGylated HbMBs (PHbMBs), and investigated their stability, immunogenicity, and their acoustic response in oxygenated and deoxygenated media in vitro. We optimized PEGylated HbMBs (PHbMBs), showing a 42% reduction in immunogenicity and significantly improved stability in vitro, while maintaining their oxygen-binding and acoustic response. In vivo, PHbMBs demonstrated similar contrast enhancement to that of non-PEGylated MBs, demonstrating that PEGylation does not decrease HbMBs' acoustic signaling. Finally, changing the gas core from air to PFB increased PHbMBs' mean circulation time more than 11-fold, without diminishing their responsiveness to oxygen. Overall, the proposed oxygen sensitive PHbMBs offer a promising avenue for real-time acoustic detection of blood oxygen levels, paving the way for potential clinical applications in monitoring critically ill patients. STATEMENT OF SIGNIFICANCE: This research explores the emergent field of Acoustic Oxygen Imaging in vivo using hemoglobin-based microbubbles. This innovative contrast agent approach involves imaging using crosslinked biomaterial comprised of the hemoglobin protein, aiming to transform the way we monitor blood oxygen levels with ultrasound. This work fundamentally addresses central concerns of improving bubble stability and circulation life for eventual clinical use, while minimizing toxicity. Importantly, we demonstrate that PEGylation of hemoglobin microbubbles enhances their stability, reduces immunogenicity, and maintains acoustic responsiveness. The incorporation of perfluorobutane into the bubble core increases the longevity of these microbubbles in circulation, while sustaining their oxygen sensitivity. Favorable in vivo results highlight the potential of this technology in real-time acoustic detection of blood oxygen levels.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hemoglobin structure and function · Ultrasound and Hyperthermia Applications · Thermal Regulation in Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Clinical targeting of the cerebral oxygen cascade to improve brain oxygenation in patients with hypoxic–ischaemic brain injury after cardiac arrest10.1007/s00134-023-07165-x ↗
2. Mechanism and treatment related to oxidative stress in neonatal hypoxic-ischemic encephalopathy10.3389/fnmol.2019.00088 ↗
3. The clinical importance of assessing tumor hypoxia: relationship of tumor hypoxia to prognosis and therapeutic opportunities10.1089/ars.2013.5378 ↗
4. Solid MRI contrast agents for long-term, quantitative in vivo oxygen sensing10.1073/pnas.1400015111 ↗
5. Redox- and hypoxia-responsive MRI contrast agents10.1002/cmdc.201402034 ↗
6. In vivo oxygen detection using exogenous hemoglobin as a contrast agent in magnetic resonance microscopy10.1002/mrm.10405 ↗
7. Molecular imaging of hypoxia10.2967/jnumed.107.045914 ↗
8. hypoxia positron emission tomography imaging with 18F-fluoromisonidazole10.1053/j.semnuclmed.2007.07.001 ↗
9. Oxygen-sensing methods in biomedicine from the macroscale to the microscale10.1002/anie.201410646 ↗
10. Pretreatment 18F-FAZA PET predicts success of hypoxia-directed radiochemotherapy using tirapazamine10.2967/jnumed.106.038570 ↗
11. Fujibayashi, Y.; Taniuchi, H.; Yonekura, Y.; Ohtani, H.; Konishi, J.; Yokoyama, A. Copper-62-ATSM: a new hypoxia imaging agent with high membrane permeability and low redox potential. 6.
12. Optical biosensors: an exhaustive and comprehensive review10.1039/C9AN01998G ↗
13. Photoacoustic brain imaging: from microscopic to macroscopic scales10.1117/1.NPh.1.1.011003 ↗
14. Optical brain imaging: a powerful tool for neuroscience10.1007/s12264-016-0053-6 ↗
15. A review of monitoring methods for cerebral blood oxygen saturation10.3390/healthcare9091104 ↗
16. biosensors based on mechanical and electrical detection techniques10.3390/s20195605 ↗
17. Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering10.1088/0031-9155/54/6/R01 ↗
18. Microbubble ultrasound contrast agents: an update10.1007/s00330-007-0623-0 ↗
19. Contrast-enhanced ultrasound: what is the evidence and what are the obstacles?10.2214/AJR.09.2553 ↗
20. Microbubble compositions, properties and biomedical applications10.1179/175889709X446507 ↗
21. Transtemporal brain contrast-enhanced ultrasound in children: preliminary experience in patients without neurological disorders10.1007/s40477-022-00713-z ↗
22. Cerebral microcirculation mapped by echo particle tracking velocimetry quantifies the intracranial pressure and detects ischemia10.1038/s41467-022-28298-5 ↗
23. Improved sensitivity of ultrasound-based subharmonic aided pressure estimation using monodisperse microbubbles10.1002/jum.15861 ↗
24. Dynamic solid-state ultrasound contrast agent for monitoring ph fluctuations in vivo10.1021/acssensors.0c00245 ↗
25. Thrombin-activatable microbubbles as potential ultrasound contrast agents for the detection of acute thrombosis10.1021/acsami.7b10592 ↗
26. Photoacoustic imaging with fiber optic technology: a review10.1016/j.pacs.2020.100211 ↗
27. Sonochemically produced hemoglobin microbubbles10.1557/PROC-372-89 ↗
28. Development and characterization of hemoglobin microbubbles for acoustic blood oxygen level dependent imaging10.1021/acssensors.3c02349 ↗
29. Mechanisms of toxicity and modulation of hemoglobin-based oxygen carriers10.1097/SHK.0000000000001044 ↗
30. PEGylation of Αα-Hb using succinimidyl propionic acid PEG 5K: conjugation chemistry and PEG shell structure dictate respectively the oxygen affinity and resuscitation fluid like properties of PEG Αα-Hbs10.3109/21691401.2014.885443 ↗
31. Engineering hemoglobin to enable homogenous PEGylation without modifying protein functionality10.1039/C9BM01773A ↗
32. Theranostic oxygen delivery using ultrasound and microbubbles10.7150/thno.4410 ↗
33. Pharmacokinetics of perfluorobutane following intravenous bolus injection and continuous infusion of SonazoidTM in healthy volunteers and in patients with reduced pulmonary diffusing capacity10.1016/j.ultrasmedbio.2007.09.019 ↗
34. Hemoglobin microbubbles and the prediction of different oxygen levels using RF data and deep learning
35. Murine echocardiography and ultrasound imaging
36. NMR reveals hydrogen bonds between oxygen and distal histidines in oxyhemoglobin10.1073/pnas.190254697 ↗
37. Chain-selective isotopic labeling for NMR studies of large multimeric proteins: application to hemoglobin10.1016/S0006-3495(00)76368-5 ↗
38. Effect of PEGylation on performance of protein microbubbles and its comparison with lipid microbubbles10.1016/j.msec.2016.10.021 ↗
39. The role of poly(ethylene glycol) brush architecture in complement activation on targeted microbubble surfaces10.1016/j.biomaterials.2011.05.027 ↗
40. Accelerated clearance of ultrasound contrast agents containing polyethylene glycol is associated with the generation of anti-polyethylene glycol antibodies10.1016/j.ultrasmedbio.2018.02.006 ↗
41. Analysis of pre-existing IgG and IgM antibodies against Polyethylene Glycol (PEG) in the general population10.1021/acs.analchem.6b03437 ↗
42. State-of-the-art materials for ultrasound-triggered drug delivery10.1016/j.addr.2013.12.010 ↗
43. synthesis of albumin microbubbles using a microfluidic device for real-time imaging and therapeutics