journal article·2023-11

Efficient reduction of the scrolling of Descemet membrane endothelial keratoplasty grafts by engineering the medium

Nidhi Gupta, Amit Kumar, Pravin K Vaddavalli, Nitish R. Mahapatra, Akhil Varshney, Pijush Ghosh

Acta Biomaterialia· Volume 171
Publisher page

Abstract

The Descemet Membrane Endothelial Keratoplasty (DMEK) procedure for corneal transplantation is challenging due to the need to unscroll the donor graft within the recipient's eye. This process of unscrolling is complex, time-consuming, leads to a loss of endothelial cells and, most importantly, can negatively impact the graft's adhesion and integration with the host tissue after surgery. This problem is particularly evident when the graft is young. However, the physics behind this scrolling is not well understood, and therefore no sustainable solution is attained. Here, we propose that the concentration gradient of the medium used during transplant leads to a displacement gradient across the graft thickness, resulting in an out-of-plane folding or scrolling of the graft tissue. Using chitosan bilayer-based experimental models, it is experimentally demonstrated that this diffusion-coupled-deformation phenomenon can successfully explain why younger donor grafts tend to scroll tighter than older ones. Most importantly, we illustrate here through experiments that the medium can be engineered to reduce the scroll tightness and thus reduce the surgical inconveniences and improve post-transplant recovery. STATEMENT OF SIGNIFICANCE: This paper addresses a major issue that surgeons face while doing Descemet Membrane Endothelial Keratoplasty (DMEK) in unscrolling grafts during the graft insertion procedure. The currently used tapping method to unscroll the graft inside the patient's eye significantly reduces endothelial cell count, thus affecting its lifetime. Surprisingly, the physics behind graft scrolling is not well understood, so no sustainable solutions are proposed by the medical community. In this work, we present the underlying mechanism of DMEK graft scroll and illustrate experimentally the reason for scroll tightness through a chitosan bilayer based experiment model. Most importantly, we have successfully demonstrated that the preserving medium of the grafts can be engineered to reduce scroll tightness.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corneal surgery and disorders · Corneal Surgery and Treatments · Ocular Surface and Contact Lens

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Step-by-step Descemet's membrane endothelial keratoplasty surgery10.4103/tjo.tjo_108_18 ↗
2. Endothelial keratoplasty update 202010.1097/ICO.0000000000002565 ↗
3. The role of novel DMEK graft shapes in facilitating intraoperative unscrolling10.1007/s00417-018-4145-z ↗
4. Effects of temperature and fluid media on the scroll width size of the Descemet's membrane endothelial keratoplasty (DMEK) donor graft10.2147/OPTH.S143427 ↗
5. Effect of fibrin glue on the biomechanical properties of human Descemet's membrane10.1371/journal.pone.0037456 ↗
6. The influence of speed during stripping in Descemet membrane endothelial keratoplasty tissue preparation10.1097/ICO.0000000000002338 ↗
7. Descemet membrane endothelial keratoplasty: update on preoperative considerations, surgical techniques, and outcomes10.4103/ijo.IJO_2933_21 ↗
8. The composition of wide-spaced collagen in normal and diseased Descemet's membrane10.3109/02713689609017610 ↗
9. Descemet's membrane development, structure, function and regeneration10.1016/j.exer.2020.108090 ↗
10. Three-dimensional arrangement of elastic fibers in the human corneal stroma10.1016/j.exer.2015.12.006 ↗
11. Elastin content and distribution in endothelial keratoplasty tissue determines direction of scrolling10.1016/j.ajo.2018.07.001 ↗
12. Scanning electron microscopy assessment of the Descemet membrane interface during DMEK graft preparation10.1038/s41598-017-18991-7 ↗
13. Elastic modulus and collagen organization of the rabbit cornea: epithelium to endothelium10.1016/j.actbio.2013.09.025 ↗
14. Cellular and nerve regeneration within a biosynthetic extracellular matrix for corneal transplantation10.1073/pnas.2536767100 ↗
15. Novel corneal endothelial cell carrier couples a biodegradable polymer and a mesenchymal stem cell-derived extracellular matrix10.1021/acsami.2c01709 ↗
16. Retinal-detachment repair and vitreous-like-body reformation via a thermogelling polymer endotamponade10.1038/s41551-019-0382-7 ↗
17. Ultrathin chitosan–poly (ethylene glycol) hydrogel films for corneal tissue engineering10.1016/j.actbio.2013.01.020 ↗
18. Construction of tissue-engineered human corneal endothelium for corneal endothelial regeneration using a crosslinked amniotic membrane scaffold10.1016/j.actbio.2022.03.039 ↗
19. Actuation and locomotion driven by moisture in paper made with natural pollen10.1073/pnas.1922560117 ↗
20. Stimuli-responsive composite biopolymer actuators with selective spatial deformation behavior10.1073/pnas.2002996117 ↗
21. Hydrophilic/hydrophobic composite shape-shifting structures10.1021/acsami.8b02444 ↗
22. Enhanced tendon healing by a tough hydrogel with an adhesive side and high drug-loading capacity10.1038/s41551-021-00810-0 ↗
23. Folding behavior and molecular mechanism of cross-linked biopolymer film in response to water10.1039/C6SM01994C ↗
24. An embedded interface regulates the underwater actuation of solvent-responsive soft grippers10.1039/D1SM01229K ↗
25. Solvent triggered irreversible shape morphism of biopolymer films10.1039/C8SM00042E ↗
26. Compositional differences between infant and adult human corneal basement membranes10.1167/iovs.07-0654 ↗
27. Structural, mechanical, and transport properties of electron beam-irradiated chitosan membranes at different doses10.3390/polym10020117 ↗
28. Eye preservation tectonic graft using glycerol-preserved donor cornea10.1038/eye.2012.192 ↗