journal article·2022-03Open access

Experimental Bi-axial tensile tests of spinal meningeal tissues and constitutive models comparison

Morgane Evin, Patrice Sudres, Pascal Weber, Yves Godio-Raboutet, Pierre-Jean Arnoux, Eric Wagnac, Yvan Petit, Yannick Tillier

Acta Biomaterialia· Volume 140

Abstract

Introduction This study aims at identifying mechanical characteristics under bi-axial loading conditions of extracted swine pia mater (PM) and dura and arachnoid complex (DAC). Methods 59 porcine spinal samples have been tested on a bi-axial experimental device with a pre-load of 0.01 N and a displacement rate of 0.05 mm·s-1. Post-processing analysis included an elastic modulus, as well as constitutive model identification for Ogden model, reduced Gasser Ogden Holzapfel (GOH) model, anisotropic GOH model, transverse isotropic and anisotropic Gasser models as well as a Mooney-Rivlin model including fiber strengthening for PM. Additionally, micro-structure of the tissue was investigated using a bi-photon microscopy. Results Linear elastic moduli of 108 ± 40 MPa were found for DAC longitudinal direction, 53 ± 32 MPa for DAC circumferential direction, with a significant difference between directions (p < 0.001). PM presented significantly higher longitudinal than circumferential elastic moduli (26 ± 13 MPa vs 13 ± 9 MPa, p < 0.001). Transversely isotropic and anisotropic Gasser models were the most suited models for DAC (r2 = 0.99 and RMSE:0.4 and 0.3 MPa) and PM (r2 = 1 and RMSE:0.06 and 0.07 MPa) modelling. Conclusion This work provides reference values for further quasi-static bi-axial studies, and is the first for PM. Collagen structures observed by two photon microscopy confirmed the use of anisotropic Gasser model for PM and the existence of fenestration. The results from anisotropic Gasser model analysis depicted the best fit to experimental data as per this protocol. Further investigations are required to allow the use of meningeal tissue mechanical behaviour in finite element modelling with respect to physiological applications. STATEMENT OF SIGNIFICANCE: This study is the first to present biaxial tensile test of pia mater as well as constitutive model comparisons for dura and arachnoid complex tissue based on such tests. Collagen structures observed by semi-quantitative analysis of two photon microscopy confirmed the use of anisotropic Gasser model for pia mater and existence of fenestration. While clear identification of fibre population was not possible in DAC, results from anisotropic Gasser model depicted better fitting on experimental data as per this protocol. Bi-axial mechanical testing allows quasi-static characterization under conditions closer to the physiological context and the results presented could be used for further simulations of physiology. Indeed, the inclusion of meningeal tissue in finite element models will allow more accurate and reliable numerical simulations.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Automotive and Human Injury Biomechanics · Elasticity and Material Modeling · Cellular and Composite Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (58)

Show source-provided references
1. Histological and biomechanical study of dura mater applied to the technique of dura splitting decompression in Chiari type I malformation
2. The collagenic architecture of human dura mater10.3171/2010.12.JNS101732 ↗
3. Mechanical strain affects dura mater biological processes: implications for immature calvarial healing10.1097/01.PRS.0000079860.14734.D6 ↗
4. Viscoelasticity of spinal cord and meningeal tissues10.1016/j.actbio.2018.05.045 ↗
5. Evaluation by fluid/structure-interaction spinal-cord simulation of the effects of subarachnoid-space stenosis on an adjacent syrinx10.1115/1.4001165 ↗
6. A poroelastic fluid/structure-interaction model of cerebrospinal fluid dynamics in the cord with syringomyelia and adjacent subarachnoid-space stenosis10.1115/1.4034657 ↗
7. Multiaxial mechanical behavior of biological materials10.1146/annurev.bioeng.5.011303.120714 ↗
8. Ultrastructural findings in human spinal pia mater in relation to subarachnoid anesthesia10.1213/01.ANE.0000113240.09354.E9 ↗
9. Regional mechanical and biochemical properties of the porcine cortical meninges10.1016/j.actbio.2018.09.004 ↗
10. Histologic comparison of the dura mater among species10.30802/AALAS-CM-19-000022 ↗
11. Microanatomy relevant to intrathecal drug delivery10.1007/978-1-4939-9798-5_4 ↗
12. Mechanical properties of bovine pia-arachnoid complex in shear10.1016/j.jbiomech.2010.09.035 ↗
13. Ultrastructure of Spinal Pia Mater
14. Tensile mechanical properties of the cervical, thoracic and lumbar porcine spinal meninges10.1016/j.jmbbm.2020.104280 ↗
15. Mechanical properties of dura mater from the rat brain and spinal cord10.1089/neu.2007.0348 ↗
16. Age-dependent residual tensile strains are present in the dura mater of rats10.1098/rsif.2005.0035 ↗
17. Anatomic and biomechanical properties of human lumbar dura mater10.1213/00000539-199303000-00014 ↗
18. Biaxial response of ovine spinal cord dura mater10.1016/j.jmbbm.2014.02.014 ↗
19. Mechanical properties of cervical dura mater
20. Mathematical model for the viscoelastic properties of dura mater
21. Poisson's ratio and strain rate dependency of the constitutive behavior of spinal dura mater10.1007/s10439-010-9924-6 ↗
22. Lumbar dura mater biomechanics: experimental characterization and scanning electron microscopy observations10.1213/00000539-199906000-00022 ↗
23. Mechanical properties of human dura mater in tension – an analysis at an age range of 2 to 94 years10.1038/s41598-019-52836-9 ↗
24. Mechanical properties of the human lumbar dura mater10.1590/S0004-282X1996000300015 ↗
25. A study of the uniaxial mechanical properties of human dura mater preserved in glycerol10.1016/0142-9612(81)90086-7 ↗
26. Mechanical behavior of fetal dura mater under large axisymmetric inflation10.1115/1.3138388 ↗
27. Cervical canal morphology: effects of neck flexion in normal condition - New elements for biomechanical simulations and surgical management10.1097/BRS.0000000000003496 ↗
28. [Structure and mechanical characteristics of spinal dura mater in different segments of sheep's spine]
29. Damage accumulation modeling and rate dependency of spinal dura mater
30. Mechanical properties and function of the spinal pia mater10.3171/spi.2004.1.1.0122 ↗
31. Micromechanical heterogeneity of the rat pia-arachnoid complex10.1016/j.actbio.2019.09.044 ↗
32. Constitutive model for brain tissue under finite compression10.1016/j.jbiomech.2011.12.023 ↗
33. Tensile strength of cranial pia mater: preliminary results10.3171/jns.2004.100.1.0111 ↗
34. Biomechanical response of the bovine pia-arachnoid complex to tensile loading at varying strain-rates
35. Spatial distribution of human arachnoid trabeculae10.1111/joa.13186 ↗
36. Subarachnoid trabeculae: a comprehensive review of their embryology, histology, morphology, and surgical significance10.1016/j.wneu.2017.12.041 ↗
37. Biaxial mechanical evaluation of planar biological materials
38. Biomechanical characterization of human dura mater10.1016/j.jmbbm.2017.12.023 ↗
39. Biaxial response of ovine spinal cord dura mater10.1016/j.jmbbm.2014.02.014 ↗
40. Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues10.1115/1.1933931 ↗
41. A constitutive equation for collagen fibers10.1016/0021-9290(72)90001-2 ↗
42. Planar biaxial testing of soft biological tissue using rakes: a critical analysis of protocol and fitting process10.1016/j.jmbbm.2016.01.011 ↗
43. Biaxial tension of fibrous tissue: using finite element methods to address experimental challenges arising from boundary conditions and anisotropy10.1115/1.4023503 ↗
44. Constitutive modeling of pia-arachnoid complex10.1007/s10439-013-0948-6 ↗
45. Mechanical characterization and identification of material parameters of porcine aortic valve leaflets10.1016/j.jmbbm.2020.104036 ↗
46. The use of digital image correlation in the biomechanical area: a review10.1080/23335432.2015.1117395 ↗
47. 2020
48. A study of the uniaxial mechanical properties of human dura mater preserved in glycerol10.1016/0142-9612(81)90086-7 ↗
49. Analysis of the uniaxial and multiaxial mechanical response of a tissue-engineered vascular graft10.1089/ten.tea.2012.0075 ↗
50. Mechanical characterization and modeling of the porcine cerebral meninges10.3389/fbioe.2020.00801 ↗
51. Mechanical characterization of spinal dura using a pd-controlled biaxial tensile tester10.1142/S0219519420500232 ↗
52. Mechanical properties and function of the spinal pia mater10.3171/spi.2004.1.1.0122 ↗
53. Rate-dependency of the mechanical behaviour of semilunar heart valves under biaxial deformation10.1016/j.actbio.2019.02.008 ↗
54. Mechanical characterization of human brain tissue10.1016/j.actbio.2016.10.036 ↗
55. Biaxial tensile tests of the porcine ascending aorta10.1016/j.jbiomech.2016.05.005 ↗
56. Review of current advances in the mechanical description and quantification of aortic dissection mechanisms10.1109/RBME.2019.2950140 ↗
57. The transverse isotropy of spinal cord white matter under dynamic load10.1115/1.4034171 ↗
58. Investigation of anteroposterior head-neck responses during severe frontal impacts using a brain-spinal cord complex FE model