Abstract
Currently, our knowledge of wear performance in total ankle replacements is limited. The aim of this study is to develop a scenario for force-controlled testing and wear testing of total ankle replacements. A force-controlled wear test was developed: based on cadaver measurements, the passive stabilization (ligaments and soft tissue) of the ankle joint was characterized and a restraint model for ankle stabilization was developed. Kinematics and kinetics acting at the replaced ankle joint were defined based on literature data and gait analysis. Afterwards, force-controlled wear testing was carried out on a mobile, three-component, total ankle replacement design. Wear was assessed gravimetrically and wear particles were analyzed. Wear testing resulted in a mean wear rate of 18.2±1.4mm(3)/10(6) cycles. Wear particles showed a mean size of 0.23μm with an aspect ratio of 1.61±0.96 and a roundness of 0.62±0.14. Wear testing of total ankle replacement shows that a relevant wear mass is generated with wear particles in a biologically relevant size range. The developed wear test provides a basis for future wear testing of total ankle replacements.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Surgery and Rehabilitation · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (95)
Show source-provided references
1. Total ankle replacement: why, when and how?
2. Challenges in total ankle arthroplasty10.1177/107110070402500402 ↗
3. Total ankle arthroplasty outcome comparison for post-traumatic and primary osteoarthritis10.3113/FAI.2010.1048 ↗
4. Scandinavian total ankle replacement (STAR)10.1097/01.blo.0000132414.41124.06 ↗
5. Total ankle replacement in association with hindfoot fusion: outcome and complications10.1302/0301-620X.92B11.24452 ↗
6. History and evolution in total ankle arthroplasty10.1093/bmb/ldn039 ↗
7. Revision rates after total joint replacement cumulative results from worldwide joint register datasets10.1302/0301-620X.93B3.25467 ↗
8. How successful are current ankle replacements? A systematic review of the literature10.1007/s11999-009-0987-3 ↗
9. Knee replacement10.1016/S0140-6736(11)60752-6 ↗
10. Garellick G KJ, Rogmark C, Herberts P. Swedish hip arthroplasty register. In Sahlgrenska University Hospital Annual report, 2009.
11. The central role of wear debris in periprosthetic osteolysis10.1007/s11420-006-9003-6 ↗
12. Periprosthetic osteolysis after total ankle arthroplasty10.1177/1071100713509247 ↗
13. 10-year survival of total ankle arthroplasties. A report on 780 cases from the Swedish Ankle Register10.3109/17453674.2011.636678 ↗
14. Total ankle arthroplasty in inflammatory joint disease with use of two mobile-bearing designs10.2106/JBJS.E.00414 ↗
15. The Scandinavian total ankle replacement: long-term, eleven to fifteen-year, survivorship analysis of the prosthesis in seventy-two consecutive patients10.2106/JBJS.K.01580 ↗
16. Characterization of the running-in period in total hip resurfacing arthroplasty: an in vivo and in vitro metal ion analysis10.2106/JBJS.H.00437 ↗
17. Comparison of polyethylene tibial insert damage from in vivo function and in vitro wear simulation10.1002/jor.20743 ↗
18. Methodology for long-term wear testing of total knee replacements10.1097/00003086-200003000-00032 ↗
19. Variation in the wear rate during the life of a total hip arthroplasty: a simulator and retrieval study10.1054/arth.2000.9194 ↗
20. Meniscal wear at a three-component total ankle prosthesis by a knee joint simulator10.1016/j.jbiomech.2006.08.002 ↗
21. Wear behaviour in total ankle replacement: a comparison between an in vitro simulation and retrieved prostheses10.1016/j.clinbiomech.2009.06.006 ↗
22. Simulation of polyethylene wear in ankle joint prostheses10.1002/jbm.b.30649 ↗
23. In vivo knee stability. A quantitative assessment using an instrumented clinical testing apparatus10.2106/00004623-197860050-00014 ↗
24. Characterizing the motion of total knee replacements in laboratory tests10.1097/01.blo.0000063599.67412.44 ↗
25. The Heidelberg foot measurement method: development, description and assessment10.1016/j.gaitpost.2005.07.003 ↗
26. Dreidimensionale Fußanalyse nach Implantation einer HINTEGRA-Sprunggelenkendoprothese10.1007/s00132-006-0937-7 ↗
27. Comparison of hip force calculations and measurements in the same patient10.1016/0883-5403(94)90136-8 ↗
28. Sensitivity of knee replacement contact calculations to kinematic measurement errors10.1002/jor.20548 ↗
29. Hip contact forces and gait patterns from routine activities10.1016/S0021-9290(01)00040-9 ↗
30. Hip joint loading during walking and running, measured in two patients10.1016/0021-9290(93)90058-M ↗
31. Direct comparison of calculated hip joint contact forces with those measured using instrumented implants. An evaluation of a three-dimensional mathematical model of the lower limb10.1016/S0021-9290(03)00072-1 ↗
32. Musculo-skeletal loading conditions at the hip during walking and stair climbing10.1016/S0021-9290(01)00039-2 ↗
33. Forces and moments telemetered from two distal femoral replacements during various activities10.1016/S0021-9290(01)00042-2 ↗
34. The forces in the distal femur and the knee during walking and other activities measured by telemetry10.1016/S0883-5403(98)90009-2 ↗
35. Validation of a lower limb model with in vivo femoral forces telemetered from two subjects10.1016/S0021-9290(97)00102-4 ↗
36. Telemeterized in vivo hip joint force data: a report on two patients after total hip surgery10.1002/jor.1100090502 ↗
37. Telemetric force measurements across the hip after total arthroplasty10.2106/00004623-198870010-00008 ↗
38. Loading of the knee joint during activities of daily living measured in vivo in five subjects10.1016/j.jbiomech.2010.03.046 ↗
39. The mark coventry award: in vivo knee forces during recreation and exercise after knee arthroplasty10.1007/s11999-008-0345-x ↗
40. In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement10.1002/jor.20655 ↗
41. Internal loads in the human tibia during gait10.1016/j.clinbiomech.2008.12.007 ↗
42. A dynamic cadaver model of the stance phase of gait: performance characteristics and kinetic validation10.1016/S0268-0033(98)00003-5 ↗
43. Ankle joint biomechanics10.1016/0021-9290(82)90017-3 ↗
44. The three-dimensional determination of internal loads in the lower extremity10.1016/S0021-9290(97)00089-4 ↗
45. The prediction of muscular load sharing and joint forces in the lower extremities during walking10.1016/0021-9290(75)90089-5 ↗
46. Force and motion analysis of the normal, diseased, and prosthetic ankle joint10.1097/00003086-197709000-00027 ↗
47. Gait analysis after successful mobile bearing total ankle replacement10.3113/FAI.2007.0313 ↗
48. GAIT analysis in patients operated with a novel total ankle prosthesis10.1016/j.gaitpost.2009.03.012 ↗
49. Ankle replacement versus arthrodesis: a comparative gait analysis study10.3113/FAI.2008.0003 ↗
50. Differences in lower limb transverse plane joint moments during gait when expressed in two alternative reference frames10.1016/j.jbiomech.2005.12.003 ↗
51. A three-dimensional kinematic and dynamic model of the lower limb10.1016/0021-9290(89)90037-7 ↗
52. Simultaneous bilateral 3-D able-bodied gait10.1016/0167-9457(96)00004-8 ↗
53. Kinetic analysis of the lower limbs during walking: what information can be gained from a three-dimensional model?10.1016/0021-9290(94)00124-M ↗
54. Effect of joint laxity on polyethylene wear in total knee replacement10.1016/j.jbiomech.2009.12.016 ↗
55. ISO 14243-1: 2009; Implants for surgery – wear of total knee-joints prostheses – part 1: loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test. International Organization for Standardization, Geneva.
56. ISO 14243–2:2009; Implants for surgery – wear of total knee-joint prostheses – Part 2: methods of measurement. International Organization for Standardization, Geneva.
57. Characterization of polyethylene wear particle: the impact of methodology10.1016/j.actbio.2013.07.039 ↗
58. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study10.1016/j.actbio.2010.09.031 ↗
59. Comparison of three joint simulator wear debris isolation techniques: acid digestion, base digestion, and enzyme cleavage10.1002/1097-4636(200108)56:2<245::AID-JBM1091>3.0.CO;2-T ↗
60. Brandt J-M, Charron K, Zhao L, MacDonald SJ, Medley JB. Calf serum constituent fractions influence polyethylene wear and microbial growth in knee simulator testing. In: Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicine 2012;226:pp. 427–40.10.1177/0954411912444248 ↗
61. Polyethylene wear and variations in knee kinematics10.1097/00003086-200111000-00015 ↗
62. Schwenke T, Kaddick C, Schneider E, Wimmer MA. Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing. In: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 2005;219:457-64.10.1243/095441105X34392 ↗
63. Knee wear simulation under conditions of highly demanding daily activities – influence on an unicompartmental fixed bearing knee design10.1016/j.medengphy.2012.12.015 ↗
64. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear10.1097/00003086-200010000-00006 ↗
65. Tribology and total hip joint replacement: current concepts in mechanical simulation10.1016/j.medengphy.2008.07.006 ↗
66. Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes
67. Wear versus thickness and other features of 5-Mrad crosslinked UHMWPE acetabular liners10.1007/s11999-010-1555-6 ↗
68. Ankle arthroplasties generate wear particles similar to knee arthroplasties10.1097/01.blo.0000132182.54217.da ↗
69. Characterization of polyethylene wear particle: the impact of methodology10.1016/j.actbio.2013.07.039 ↗
70. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?10.1007/s10856-014-5271-8 ↗
71. Ingham E, Fisher J. Biological reactions to wear debris in total joint replacement. In: Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicine 2000;214:21-37.10.1243/0954411001535219 ↗
72. Total ankle replacement: a population-based study of 515 cases from the finnish arthroplasty register10.3109/17453671003685459 ↗
73. 257 ankle arthroplasties performed in Norway between 1994 and 200510.1080/17453670710014257 ↗
74. Komplikationen und Revisionseingriffe nach OSG-Totalendoprothesen10.1007/s10302-005-0128-6 ↗
75. Scandinavian total ankle replacement: a 3.7-year average followup of 65 patients10.1097/01.blo.0000132245.18548.09 ↗
76. Revision rates after total ankle arthroplasty in sample-based clinical studies and national registries10.3113/FAI.2011.0740 ↗
77. Analysis of retrieved agility (TM) total ankle arthroplasty systems10.3113/FAI.2009.0815 ↗
78. The Scandinavian total ankle replacement: long-term, eleven to fifteen-year, survivorship analysis of the prosthesis in seventy-two consecutive patients10.2106/JBJS.K.01580 ↗
79. Impact of complications in total ankle replacement and ankle arthrodesis analyzed with a validated outcome measurement10.2106/JBJS.J.00103 ↗
80. Changes in gait following the Scandinavian total ankle replacement10.2106/JBJS.J.00347 ↗
81. Three-dimensional kinematics of an unconstrained ankle arthroplasty: a preliminary in vivo videofluoroscopic feasibility study10.3113/FAI.2012.0883 ↗
82. A functional outcome study comparing total ankle arthroplasty (TAA) subjects with pain to subjects with absent level of pain by means of videofluoroscopy10.1016/j.fas.2012.04.001 ↗
83. Kinematic analysis of the agility total ankle during gait10.1177/107110070602701120 ↗
84. In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait10.1016/j.jbiomech.2012.05.043 ↗
85. A determination of ankle kinematics using fluoroscopy10.1177/107110070002100412 ↗
86. In vivo kinematics of the salto total ankle prosthesis10.3113/FAI.2008.1117 ↗
87. Misalignment of total ankle components can induce high joint contact pressures10.2106/JBJS.I.00287 ↗
88. Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers10.1016/j.jmbbm.2013.05.020 ↗
89. Cross-shear in metal-on-polyethylene articulation of orthopaedic implants and its relationship to wear10.1016/j.wear.2013.01.069 ↗
90. Effect of anterior–posterior and internal–external motion restraint during knee wear simulation on a posterior stabilised knee design10.1016/j.jbiomech.2012.10.017 ↗
91. Analysis of joint laxity after total ankle arthroplasty: cadaver study10.1016/j.clinbiomech.2009.06.007 ↗
92. Increase of tibial slope reduces backside wear in medial mobile bearing unicompartmental knee arthroplasty10.1016/j.clinbiomech.2013.08.006 ↗
93. Total ankle replacement in patients with significant pre-operative deformity of the hindfoot10.1302/0301-620X.91B4.20855 ↗
94. The effect of three-component total ankle replacement malalignment on clinical outcome: pain relief and functional outcome in 317 consecutive patients10.2106/JBJS.J.01415 ↗
95. Effect of anterior translation of the talus on outcomes of three-component total ankle arthroplasty10.1186/1471-2474-14-260 ↗