From in vitro evaluation to human postmortem pre-validation of a radiopaque and resorbable internal biliary stent for liver transplantation applications
Source abstract
Abstract
The implantation of an internal biliary stent (IBS) during liver transplantation has recently been shown to reduce biliary complications. To avoid a potentially morbid ablation procedure, we developed a resorbable and radiopaque internal biliary stent (RIBS). We studied the mechanical and radiological properties of RIBS upon in vivo implantation in rats and we evaluated RIBS implantability in human anatomical specimens. For this purpose, a blend of PLA50-PEG-PLA50 triblock copolymer, used as a polymer matrix, and of X-ray-visible triiodobenzoate-poly(ε-caprolactone) copolymer (PCL-TIB), as a radiopaque additive, was used to design X-ray-visible RIBS. Samples were implanted in the peritoneal cavity of rats. The radiological, chemical, and biomechanical properties were evaluated during degradation. Further histological studies were carried out to evaluate the degradation and compatibility of the RIBS. A human cadaver implantability study was also performed. The in vivo results revealed a decline in the RIBS mechanical properties within 3 months, whereas clear and stable X-ray visualization of the RIBS was possible for up to 6 months. Histological analyses confirmed compatibility and resorption of the RIBS, with a limited inflammatory response. The RIBS could be successfully implanted in human anatomic specimens. The results reported in this study will allow the development of trackable and degradable IBS to reduce biliary complications after liver transplantation. STATEMENT OF SIGNIFICANCE: Biliary reconstruction during liver transplantation is an important source of postoperative morbidity and mortality although it is generally considered as an easy step of a difficult surgery. In this frame, internal biliary stent (IBS) implantation is beneficial to reduce biliary anastomosis complications (leakage, stricture). However, current IBS are made of non-degradable silicone elastomeric materials, which leads to an additional ablation procedure involving potential complications and additional costs. The present study provides in vitro and human postmortem implantation data related to the development and evaluation of a resorbable and radiopaque internal biliary stent (RIBS) that could tackle these drawbacks.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Organ Transplantation Techniques and Outcomes · Gallbladder and Bile Duct Disorders · Cholangiocarcinoma and Gallbladder Cancer Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (62)
Show source-provided references
1. Biliary complications following liver transplantation in the model for end-stage liver disease era: effect of donor, recipient, and technical factors10.1002/lt.21354 ↗
2. Biliary complications after liver transplantation: old problems and new challenges10.1111/ajt.12034 ↗
3. Biliary reconstruction, its complications and management of biliary complications after adult liver transplantation: a systematic review of the incidence, risk factors and outcome
4. Biliary reconstruction with or without an intraductal removable stent in liver transplantation: study protocol for a randomized controlled trial10.1186/s13063-015-1139-6 ↗
5. Routine use of the t tube in the biliary reconstruction of liver transplantation: is it worthwhile?10.1016/S0041-1345(99)00398-X ↗
6. Biliary reconstruction using a side-to-side choledochocholedochostomy with or without T-Tube in deceased donor liver transplantation10.1097/SLA.0b013e3181bd920a ↗
7. Biliary tract complications after liver transplantation: a review10.1159/000144653 ↗
8. T-tube or no T-tube in reconstruction of the biliary tract during orthotopic liver transplantation - systematic review and meta-analysis10.1002/lt.22070 ↗
9. A cost-effectiveness analysis of biliary anastomosis with or without T-tube after orthotopic liver transplantation10.1034/j.1600-6143.2001.10210.x ↗
10. Randomized trial of choledochocholedochostomy with or without a t tube in orthotopic liver transplantation10.1097/00000658-200103000-00019 ↗
11. Orthotopic liver transplantation: t-Tube or not T-Tube? systematic review and meta-analysis of results10.1097/TP.0b013e3181a5cf3f ↗
12. Systematic review and meta-analysis of biliary reconstruction techniques in orthotopic deceased donor liver transplantation10.1007/s00534-010-0346-5 ↗
13. Clinical trial on the cost-effectiveness of T-tube use in an established deceased donor liver transplantation program10.1111/j.1399-0012.2007.00688.x ↗
14. Internal biliary stenting in liver transplantation10.1007/s00423-018-1669-y ↗
15. Removable intraductal stenting in duct-to-duct biliary reconstruction in liver transplantation10.1111/j.1432-2277.2011.01339.x ↗
16. Internal biliary stenting in orthotopic liver transplantation
17. Do biliary endoprostheses decrease biliary complications after liver transplantation?10.1016/j.transproceed.2003.08.017 ↗
18. Endoscopic management of biliary leaks after T-Tube removal in liver transplant recipients: nasobiliary drainage versus biliary stenting10.1053/jlts.2000.8200 ↗
19. Biliary complications following liver transplantation
20. Biliary complications after liver transplantation10.1586/17474124.2015.967761 ↗
21. Synthetic biodegradable polymers as orthopedic devices10.1016/S0142-9612(00)00101-0 ↗
22. Tokar · Gastrointest. Endosc · 2011 · 74 · 95410.1016/j.gie.2011.07.028 ↗
23. Prevention of intra-abdominal adhesion using electrospun PEG/PLGA nanofibrous membranes10.1016/j.msec.2017.04.017 ↗
24. Bioabsorbable and biocompatible stents. is a new revolution coming?
25. Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone10.1016/0142-9612(96)85762-0 ↗
26. A new wave in treatment of vascular occlusive disease: biodegradable stents—clinical experience and scientific principles10.1016/j.jvir.2008.11.007 ↗
27. Feasibility of biodegradable PLGA common bile duct stents: an in vitro and in vivo study10.1007/s10856-008-3672-2 ↗
28. Feasibility of biodegradable PLGA common bile duct stents: an in vitro and in vivo study10.1007/s10856-008-3672-2 ↗
29. Study of biodegradable and self-expandable PLLA helical biliary stent in vivo and in vitro10.1007/s10856-006-9223-9 ↗
30. A novel biodegradable biliary stent in the endoscopic treatment of cystic-duct leakage after cholecystectomy10.1016/j.gie.2006.11.059 ↗
31. Synthetic bioabsorbable stent material for duct-to-duct biliary reconstruction10.1016/j.jss.2008.02.056 ↗
32. Well-organized neointima of large-pore poly(L-lactic acid) vascular graft coated with poly(L-lactic-co-ε-caprolactone) prevents calcific deposition compared to small-pore electrospun poly(L-lactic acid) graft in a mouse aortic implantation model10.1016/j.atherosclerosis.2014.09.030 ↗
33. Biomaterial-driven in situ cardiovascular tissue engineering-a multi-disciplinary perspective10.1038/s41536-017-0023-2 ↗
34. Development of bioresorbable hydrophilic-hydrophobic electrospun scaffolds for neural tissue engineering10.1021/acs.biomac.6b00820 ↗
35. Biomimetic neural scaffolds: a crucial step towards optimal peripheral nerve regeneration10.1039/C8BM00260F ↗
36. Composite porous scaffold of PEG/PLA support improved bone matrix deposition in vitro compared to PLA-only scaffolds10.1002/jbm.a.36336 ↗
37. PLA-poloxamer/poloxamine copolymers for ligament tissue engineering: sound macromolecular design for degradable scaffolds and MSC differentiation10.1039/C4BM00433G ↗
38. Rolled knitted scaffolds based on PLA-pluronic copolymers for anterior cruciate ligament reinforcement: a step by step conception: ROLLED KNITTED SCAFFOLDS10.1002/jbm.b.33604 ↗
39. Mechanical behaviour׳s evolution of a PLA-b-PEG-b-PLA triblock copolymer during hydrolytic degradation10.1016/j.jmbbm.2016.02.015 ↗
40. A non-linear viscoelastic model to describe the mechanical behavior's evolution of biodegradable polymers during hydrolytic degradation10.1016/j.polymdegradstab.2016.07.014 ↗
41. The novel use of a biodegradable stent placed by percutaneous transhepatic cholangiography for the treatment of a hepaticojejunostomy biliary leak following an extended left hepatectomy and pancreaticoduodenectomy10.1308/003588414X13946184901326 ↗
42. Biodegradable biliary stent implantation in the treatment of benign bilioplastic-refractory biliary strictures: preliminary experience10.1007/s00330-013-2947-2 ↗
43. Biodegradable biliary stent in the endoscopic treatment of cystic duct leak after cholecystectomy: the first case report and review of literature10.1089/lap.2015.0068 ↗
44. Tantalum-loaded polyurethane microspheres for particulate embolization: preparation and properties10.1016/0142-9612(91)90154-3 ↗
45. Barium sulphate-loaded p(HEMA) microspheres as artificial emboli: preparation and properties10.1016/0142-9612(90)90061-T ↗
46. Enhanced visualization of biodegradable polymeric vascular scaffolds by incorporation of gold, silver and magnetite nanoparticles10.1177/0885328212443393 ↗
47. Biocompatibility of a new bioabsorbable radiopaque stent material (BaSO4 containing poly-L,D-lactide) in the rat pancreas
48. A novel radiopaque biodegradable stent for pancreatobiliary applications–the first human phase I trial in the pancreas
49. In vitro cytocompatibility of radio-opacifiers used in ureteral endoprosthesis10.1016/S0142-9612(98)00198-7 ↗
50. A nontoxic additive to introduce X-Ray contrast into poly(lactic acid). implications for transient medical implants such as bioresorbable coronary vascular scaffolds10.1002/adhm.201300215 ↗
51. Synthesis of an X-ray opaque biodegradable copolyester by chemical modification of poly (epsilon-caprolactone)10.1016/j.biomaterials.2006.05.032 ↗
52. Synthesis and processability into textile structures of radiopaque, biodegradable polyesters and poly(ester-urethanes): radiopaque, biodegradable polyesters and poly(ester-urethanes)10.1002/pi.4707 ↗
53. Non-invasive monitoring of in vivo degradation of a radiopaque thermoreversible hydrogel and its efficacy in preventing post-operative adhesions10.1016/j.actbio.2017.03.042 ↗
54. Radiopaque poly(ε-caprolactone) as additive for X-ray imaging of temporary implantable medical devices10.1039/C5RA19488A ↗
55. Investigation on the properties of linear PLA-poloxamer and star PLA-poloxamine copolymers for temporary biomedical applications10.1016/j.msec.2013.06.001 ↗
56. Bioelectrodes modified with chitosan for long-term energy supply from the body10.1039/C4EE03430A ↗
57. C. Kilkenny, W. Browne, I.C. Cuthill, M. Emerson, D.G. Altman, Animal Research: Reporting in vivo experiments—the arrive guidelines, (n.d.) 3.
58. Polymerization of l, l -Lactide initiated by aluminum isopropoxide trimer or tetramer10.1021/ma971737k ↗
59. Synthesis and degradation of PLA–PCL–PLA triblock copolymer prepared by successive polymerization of ε-caprolactone and dl-lactide10.1016/j.polymer.2004.10.054 ↗
60. Biomechanical behaviour of human bile duct wall and impact of cadaveric preservation processes10.1016/j.jmbbm.2019.07.001 ↗
61. Treatment strategy for hilar cholangiocarcinoma, with special reference to the limits of ductal resection in right-sided hepatectomies10.1007/s00534-006-1190-5 ↗
62. Biliary reconstruction in right lobe living-donor liver transplantation: comparison of different techniques in 321 recipients10.1097/01.sla.0000206419.65678.2e ↗