journal article·2015-10

Degree of bioresorbable vascular scaffold expansion modulates loss of essential function

Jahid Ferdous, Vijaya B. Kolachalama, Kumaran Kolandaivelu, Tarek Shazly

Acta Biomaterialia· Volume 26
Publisher page

Abstract

Drug-eluting bioresorbable vascular scaffolds (BVSs) have the potential to restore lumen patency, enable recovery of the native vascular environment, and circumvent late complications associated with permanent endovascular devices. To ensure therapeutic effects persist for sufficient times prior to scaffold resorption and resultant functional loss, many factors dictating BVS performance must be identified, characterized and optimized. While some factors relate to BVS design and manufacturing, others depend on device deployment and intrinsic vascular properties. Importantly, these factors interact and cannot be considered in isolation. The objective of this study is to quantify the extent to which degree of radial expansion modulates BVS performance, specifically in the context of modifying device erosion kinetics and evolution of structural mechanics and local drug elution. We systematically varied degree of radial expansion in model BVS constructs composed of poly dl-lactide-glycolide and generated in vitro metrics of device microstructure, degradation, erosion, mechanics and drug release. Experimental data permitted development of computational models that predicted transient concentrations of scaffold-derived soluble species and drug in the arterial wall, thus enabling speculation on the short- and long-term effects of differential expansion. We demonstrate that degree of expansion significantly affects scaffold properties critical to functionality, underscoring its relevance in BVS design and optimization. Statement of significance Bioresorbable vascular scaffold (BVS) therapy is beginning to transform the treatment of obstructive artery disease, owing to effective treatment of short term vessel closure while avoiding long term consequences such as in situ, late stent thrombosis - a fatal event associated with permanent implants such as drug-eluting stents. As device scaffolding and drug elution are temporary for BVS, the notion of using this therapy in lieu of existing, clinically approved devices seems attractive. However, there is still a limited understanding regarding the optimal lifetime and performance characteristics of erodible endovascular implants. Several engineering criteria must be met and clinical endpoints confirmed to ensure these devices are both safe and effective. In this manuscript, we sought to establish general principles for the design and deployment of erodible, drug-eluting endovascular scaffolds, with focus on how differential expansion can modulate device performance.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Electrospun Nanofibers in Biomedical Applications · Aortic aneurysm repair treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Design principles and performance of bioresorbable polymeric vascular scaffolds10.4244/EIJV5IFA3 ↗
2. 6-Month clinical outcomes following implantation of the bioresorbable everolimus-eluting vascular scaffold in vessels smaller or larger than 2.5 mm10.1016/j.jacc.2011.02.052 ↗
3. Biodegradable stents “fulfilling the mission and stepping away”10.1161/01.CIR.102.4.371 ↗
4. From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade?10.1093/eurheartj/ehr384 ↗
5. Bioresorbable scaffolds: rationale, current status, challenges, and future10.1093/eurheartj/eht542 ↗
6. A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods10.1016/S0140-6736(09)60325-1 ↗
7. Bioresorbable scaffold the advent of a new era in percutaneous coronary and peripheral revascularization?10.1161/CIRCULATIONAHA.110.971606 ↗
8. Comparison of in vivo acute stent recoil between the bioresorbable everolimus-eluting coronary scaffolds (revision 1.0 and 1.1) and the metallic everolimus-eluting stent
9. D.J. Schneck, An outline of cardiovascular structure and function, in: Biomedical Engineering Handbook Bd, 2010, pp. 1-1.
10. J. Ferdous, C. Chong, Effect of atherosclerotic plaque on drug delivery from drug-eluting stent, in: 13th International Conference on Biomedical Engineering, Springer, 2009. pp. 1519–22.10.1007/978-3-540-92841-6_376 ↗
11. A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial10.1016/S0140-6736(08)60415-8 ↗
12. Biodegradable stents with elastic memory10.1016/j.biomaterials.2005.09.002 ↗
13. Factors affecting the degradation and drug-release mechanism of poly (lactic acid) and poly[(lactic acid)-co-(glycolic acid)]10.1002/pi.1697 ↗
14. Effect of radio-opaque filler on biodegradable stent properties10.1002/jbm.a.30714 ↗
15. A novel model and experimental analysis of hydrophilic and hydrophobic agent release from biodegradable polymers10.1002/jbm.a.32171 ↗
16. In vitro study of release mechanisms of paclitaxel and rapamycin from drug-incorporated biodegradable stent matrices10.1016/j.jconrel.2004.04.011 ↗
17. Impact of polymer structure and composition on fully resorbable endovascular scaffold performance10.1016/j.actbio.2012.12.011 ↗
18. Assessment of material by-product fate from bioresorbable vascular scaffolds10.1007/s10439-011-0445-8 ↗
19. Diffusion-limited binding explains binary dose response for local arterial and tumour drug delivery10.1111/j.1365-2184.2009.00602.x ↗
20. Mechanisms of tissue uptake and retention in zotarolimus-coated balloon therapy10.1161/CIRCULATIONAHA.113.002051 ↗
21. J. Ferdous, Numerical modeling of local pharmacokinetics associated with drug-eluting stent (Ph.D. Thesis), Nanyang Technological University, 2009.
22. Specific binding to intracellular proteins determines arterial transport properties for rapamycin and paclitaxel10.1073/pnas.0400918101 ↗
23. Arterial heparin deposition: role of diffusion, convection, and extravascular space
24. Hydrolytic degradation of devices based on poly (dl-lactic acid) size-dependence10.1016/0142-9612(95)93258-F ↗
25. J. Ferdous, Identifying performance criteria of fully bioresorbable scaffolds for endovascular applications (Ph.D. Dissertation), University of South Carolina, 2014.
26. Mechanical deformation of polymer matrix controlled release devices modulates drug release10.1002/jbm.820261207 ↗
27. Influences of tensile load on in vitro degradation of an electrospun poly (l-lactide-co-glycolide) scaffold10.1016/j.actbio.2010.02.023 ↗
28. Three-year results of clinical follow-up after a bioresorbable everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB trial10.4244/EIJ30V6I4A76 ↗
29. Bioresorbable polymeric vascular scaffolds a cautionary tale10.1161/CIRCINTERVENTIONS.111.963710 ↗
30. Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings10.1161/CIRCULATIONAHA.110.003210 ↗
31. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial10.1016/S0735-1097(03)00119-0 ↗
32. Modeling the response of nonlinear viscoelastic biodegradable polymeric stents10.1016/j.ijsolstr.2011.12.007 ↗