In vitro testing of Al2O3–Nb composite for femoral head applications in total hip arthroplasty
Source abstract
Abstract
Alumina (Al(2)O(3)) bearings in total hip arthroplasty lead to low wear rates, but catastrophic failure of Al(2)O(3) femoral heads, while rare, remains a concern. In the present work, a composite of Al(2)O(3) and niobium (Nb) was tested in vitro for potential use as an alternative femoral head material in vivo. Dense composite laminates of Al(2)O(3) and Nb were fabricated by hot pressing, and their microstructure and mechanical properties were evaluated. The flexural strength of Al(2)O(3)-Nb laminates in four-point loading was 720+/-40MPa, compared with a value of 460+/-110MPa for Al(2)O(3). Scanning electron microscopy and X-ray diffraction showed a well-bonded interface between the Al(2)O(3) and Nb without measurable formation of an interfacial reaction phase. The interfacial shear strength between Al(2)O(3) and Nb, measured by a double-notched specimen test, was 290+/-15MPa. The feasibility of fabricating prototype femoral heads (32mm in diameter), consisting of an Al(2)O(3) surface layer (2-3mm thick) and a Nb core, by hot pressing was shown. The composite femoral head combined the low wear of an Al(2)O(3) articulating surface with the safety of a ductile metal femoral head.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Powder Metallurgy Techniques and Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Changing demographics of patients with total joint replacement10.1097/01.blo.0000188066.01833.4f ↗
2. Ceramics for prosthetic hip and knee joint replacement10.1111/j.1551-2916.2007.01725.x ↗
3. Alumina ceramic bearings for total hip arthroplasty: 5-year results of a prospective randomized study10.1097/01.blo.0000162995.50971.39 ↗
4. The reliability of modern alumina bearings in total hip arthroplasty10.1053/j.sart.2006.09.004 ↗
5. Ceramic-on ceramic total hip arthroplasty: update10.1016/j.arth.2008.06.003 ↗
6. Squeaking hips10.2106/JBJS.H.00867 ↗
7. Differences in the fretting corrosion of metal–metal and ceramic–metal modular junctions of total hip replacements10.1016/S0736-0266(03)00186-4 ↗
8. Effect of impact assembly on the fretting corrosion of modular hip tapers10.1002/jor.20048 ↗
9. Optimization of the stress distribution in ceramic femoral heads by means of finite element analysis10.1243/09544119JEIM429 ↗
10. Ceramic prosthetic femoral head: the effect of the contact stress distribution
11. Potential coatings in total hip replacement10.1097/01.blo.0000150000.75660.ff ↗
12. Wear analysis of a retrieved hip implant with titanium nitride coating10.1016/S0883-5403(97)90164-9 ↗
13. The in vivo wear performance of prosthetic femoral heads with titanium nitride coating10.1016/S0142-9612(99)00246-X ↗
14. An oxidized Zr ceramic surfaced femoral component for total knee arthroplasty10.1097/01.blo.0000093003.90435.1f ↗
15. Reduced wear with oxidized zirconium femoral heads10.2106/00004623-200300004-00013 ↗
16. Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components10.2106/00004623-200100022-00004 ↗
17. Damage to Oxinium femoral heads subsequent to hip arthroplasty dislocation10.1016/j.arth.2006.07.005 ↗
18. Surface damage to an oxinium femoral prosthesis after dislocation10.1302/0301-620X.89B4.17557 ↗
19. ASM Handbook. 10th ed., Materials Park, OH: ASM International; 2000.
20. Fatigue and corrosion fatigue properties of metallic biomaterials
21. Electron microscopy studies of defects at diffusion-bonded Nb/Al2O3 interfaces10.1016/0001-6160(89)90012-6 ↗
22. Investigation of the chemistry and bonding at niobium–sapphire interfaces10.1557/JMR.1994.2574 ↗
23. Structure and composition of metal–ceramic interfaces10.1016/0955-2219(95)00194-8 ↗
24. Stansbury · 2000
25. Zirconium and niobium affect human osteoblasts, fibroblasts, and lymphocytes in a similar manner to more traditional implant alloy metals
26. Effect of MgO solute on the microstructure development in Al2O310.1111/j.1151-2916.1986.tb04719.x ↗
27. ASTM designation D-3846–79: standard test method for for in-plane shear strength of reinforced plastics. ASTM, 1985; 208–10.
28. Interlaminar shear strength of fiber-reinforced composites10.1016/0010-4361(75)90327-4 ↗
29. Assessment of the double-notched shear test for interlaminar shear characterization of a unidirectional graphite/epoxy under static and fatigue loading10.1023/A:1008866705868 ↗
30. The powder vehicle hot-pressing technique