journal article·2014-07

Intervertebral disc degeneration induced by intradiscal poly(methyl methacrylate) leakage after spine augmentation in an in vivo rabbit model

Haiqing Mao, Dechun Geng, Xuesong Zhu, Shundong Ji, Mo Zhu, Maofeng Gao, Jun Zou, Huilin Yang

Acta Biomaterialia· Volume 10· Issue 7
Publisher page

Abstract

Although intradiscal cement leakage is a common complication of spine augmentation, the effects of cement leakage into the intervertebral disc (IVD) have not been well investigated. This study aimed to determine the effects of cement leakage on IVD degeneration in rabbits. Poly(methyl methacrylate) (PMMA) particles were injected into lumbar discs of rabbits using 26 G needles. Tissue effects were assessed using disc height, sagittal T2-weighted images, histology and immunohistochemistry. The results showed that stimulation with PMMA particles significantly reduced disc height compared with that in the sham-operation group at 3 weeks after injection. The mean signal intensity of the operated discs showed little to no changes among all groups at 3 weeks post-operation. After 6 weeks, the signal intensity of the PMMA-injected group decreased by 22% compared with that in the sham-operation group. Histological and quantitative immunohistochemical examination indicated phenotypic tissue changes from cartilaginous tissue into fibrotic tissue, with apparent degeneration in the PMMA group. Additionally, more collagen type II-containing tissues, but fewer matrix metalloproteinase-7-positive cells or apoptotic cells, were detected in the sham-operation group. The PMMA particle-induced degeneration rate was slower than that of the degeneration group, whereas the histologic data showed no difference in the progression of degeneration between the two groups. These data suggest that PMMA particles can moderately accelerate disc degeneration compared with the 18 G needle puncture model. In conclusion, intradiscal injection of PMMA particles induced significant IVD degeneration in vivo. Therefore, further study of the adverse effects of PMMA leakage on IVD degeneration is required.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spine and Intervertebral Disc Pathology · Spinal Fractures and Fixation Techniques · Pelvic and Acetabular Injuries

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. A randomized trial of vertebroplasty for osteoporotic spinal fractures10.1056/NEJMoa0900563 ↗
2. A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures10.1056/NEJMoa0900429 ↗
3. Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): a randomised controlled trial10.1016/S0140-6736(09)60010-6 ↗
4. Vertebroplasty versus conservative treatment in acute osteoporotic vertebral compression fractures (Vertos II): an open-label randomised trial10.1016/S0140-6736(10)60954-3 ↗
5. Unilateral versus bilateral balloon kyphoplasty for multilevel osteoporotic vertebral compression fractures: a prospective study10.1097/BRS.0b013e3181f99d70 ↗
6. Trends of inpatient spine augmentation: 2001–200810.3174/ajnr.A2503 ↗
7. Biomechanical characteristics of cement/gelatin mixture for prevention of cement leakage in vertebral augmentation10.1007/s00586-013-2886-2 ↗
8. Balloon kyphoplasty and vertebroplasty for vertebral compression fractures: a comparative systematic review of efficacy and safety10.1097/01.brs.0000244639.71656.7d ↗
9. Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies10.1097/01.brs.0000229254.89952.6b ↗
10. Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate: a case report10.2106/00004623-200107000-00014 ↗
11. Pulmonary cement embolism: a complication of percutaneous vertebroplasty10.1080/02841850701422153 ↗
12. Pulmonary cement embolism associated with percutaneous vertebroplasty or kyphoplasty: a systematic review10.1111/j.1757-7861.2012.00193.x ↗
13. Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate10.1097/01.BRS.0000076825.12630.3C ↗
14. Morphological changes of injected calcium phosphate cement in osteoporotic compressed vertebral bodies10.1007/s00198-009-0911-4 ↗
15. Effect of vertebroplasty filler materials on viability and gene expression of human nucleus pulposus cells10.1002/jor.20532 ↗
16. Role of direct estrogen receptor signaling in wear particle-induced osteolysis10.1016/j.biomaterials.2012.10.030 ↗
17. Role of the Toll-like receptor pathway in the recognition of orthopedic implant wear-debris particles10.1016/j.biomaterials.2011.04.046 ↗
18. A novel rabbit model of mild, reproducible disc degeneration by an anulus needle puncture: correlation between the degree of disc injury and radiological and histological appearances of disc degeneration10.1097/01.brs.0000148152.04401.20 ↗
19. Regenerative effects of transplanting mesenchymal stem cells embedded in atelocollagen to the degenerated intervertebral disc10.1016/j.biomaterials.2005.06.038 ↗
20. Caspase 3 as a therapeutic target for regulation of intervertebral disc degeneration in rabbits10.1002/art.30251 ↗
21. Effect of autologous platelet-rich plasma-releasate on intervertebral disc degeneration in the rabbit annular puncture model: a preclinical study10.1186/ar4084 ↗
22. An injectable hydrogel incorporating mesenchymal precursor cells and pentosan polysulphate for intervertebral disc regeneration10.1016/j.biomaterials.2013.08.072 ↗
23. Perichondrium directed cartilage formation in silk fibroin and chitosan blend scaffolds for tracheal transplantation10.1016/j.actbio.2011.05.012 ↗
24. Human disc degeneration is associated with increased MMP 7 expression10.1080/10520290601005298 ↗
25. The early stage adjacent disc degeneration after percutaneous vertebroplasty and kyphoplasty in the treatment of osteoporotic VCFs10.1371/journal.pone.0046323 ↗
26. The use of a quadruped as an in vivo model for the study of the spine – biomechanical considerations10.1007/s005860100346 ↗
27. Stress analysis of a canine spinal motion segment using the finite element technique10.1016/0021-9290(94)90279-8 ↗
28. The effect of relative needle diameter in puncture and sham injection animal models of degeneration10.1097/BRS.0b013e318166e0a2 ↗
29. The effect of injection volume on disc degeneration in a rat tail model10.1097/BRS.0b013e3182027d42 ↗
30. Effect of vertebral cement augmentation with polymethylmethacrylate on intervertebral disc and bone tissue10.1002/jbm.b.31990 ↗
31. Subsequent fracture after percutaneous vertebroplasty can be predicted on preoperative multidetector row CT10.3174/ajnr.A1722 ↗
32. Analysis of aging and degeneration of the human intervertebral disc. Comparison of surgical specimens with normal controls10.1097/00007632-199804010-00001 ↗
33. Intervertebral disc degeneration: the role of the mitochondrial pathway in annulus fibrosus cell apoptosis induced by overload10.1016/S0002-9440(10)63179-3 ↗
34. Temperature elevation caused by bone cement polymerization during vertebroplasty10.1016/S8756-3282(99)00127-1 ↗
35. Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty10.1097/01.BRS.0000076829.54235.9F ↗