journal article·2010-04

Radially arrayed nanopillar formation on metallic stent wire surface via radio-frequency plasma

Mariana C. Loya, Eunsung Park, Li Han Chen, Karla S. Brammer, Sungho Jin

Acta Biomaterialia· Volume 6· Issue 4
Publisher page

Abstract

MP35N (Co-Ni-Cr-Mo alloy) is an important stent implant material for which many aspects, that include nanostructured surfaces, are yet to be understood. The present study provides the first creation of radially emanating metallic nanopillar structures on the surface of MP35N stent alloy wires; a novel textured surface structuring derived via controlled RF processing technique. The goal of this study was to characterize the newly found structures, identify evolution stages of nanopillar formations, as well as optimize RF process parameters for controlled surface texturing technique for stent wire materials. The exposure of a stent alloy wire, 250 microm diameter Co-Ni-Cr-Mo alloy (MP35N), to parameter-controlled RF environment resulted in dense surface nanostructures consisting of high-aspect-ratio dendritic nanopillars/nanowires. Extensive surface characterization and local compositional analyses by Transmission Electron Microscopy (TEM), Energy Dispersive X-ray analysis (EDX) and X-ray photoelectron spectroscopy (XPS) show increased values of Mo contents on the outer edges of protruding nanopillars, indicating a possibility of the higher Mo content phase contributing to the differential plasma sputter etching on the MP35N surface and resultant nanowire formation. A comparative investigation on single phase alloy versus multi-phase alloy seems to point to the importance of phase segregation for successful nanowire formation by RF plasma treatment. In addition to MP35N, some specific single phased materials, such as Fe-Ni and Fe-Cr alloys or Pt metal wire, were exposed in same RF plasma conditions and results did not form the complex structures found on MP35N samples. For the purpose of this study, metallic stent wires that have nanostructured surfaces can be considered a "polymer-less" approach to surface modification, The creation and characterization of radially arrayed nanostructured surfaces has been demonstrated on MP35N stent alloy wires using this RF plasma process; where such nanostructured surfaces contribute to design concepts that may enhance endotheliazation of stent materials via surface texturing modification.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Ion-surface interactions and analysis · Metal and Thin Film Mechanics · Integrated Circuits and Semiconductor Failure Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Early restenosis after drug-eluting stent implantation: a putative role for platelet activation
2. Endovascular versus open repair for abdominal aortic aneurysm: EVAR trial 110.1038/ncpcardio0281 ↗
3. Park E, Taylor K, Casey K, Morud M. A novel surface texturing technology. Functional Coatings and Surface Engineering Conference 2008, Montreal, June 2008 and “Plasma surface texturing of metals”. Boston: American Vacuum Society; Oct 2008.
4. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents10.1001/jama.293.17.2126 ↗
5. The evolving impact of microfabrication and nanotechnology on stent design10.1016/j.jvs.2006.08.046 ↗
6. Endothelial and vascular smooth muscle cell function on poly9lactic-co-glycolic acid) with nano-structured surface features10.1016/S0142-9612(03)00471-X ↗
7. Theory of sputtering. I. sputtering yield of amorphous and polycrystalline targets10.1103/PhysRev.184.383 ↗
8. Design, fabrication and evaluation of nanoscale surface topography as a tool in directing differentiation and organisation of embryonic stem-cell-derived neural precursors10.1016/j.mee.2009.01.032 ↗
9. Picha GJ, Tissue Response to Peritoneal Implants. NASA CR-159817; June 1980.
10. The evolution of cardiovascular stent materials and surfaces in response to clinical drivers: a review10.1016/j.actbio.2008.11.012 ↗
11. Electrochemical behavior of MP35N implant alloy in simulated physiological media10.1149/1.2221854 ↗
12. Available from: .
13. Fracture properties of multiphase alloy MP35N10.1016/S0921-5093(02)00809-2 ↗
14. Anomalous plastic behavior of fin-grained MP35N alloy during room temperature tensile testing10.1016/j.jmatprotec.2004.04.280 ↗
15. The secondary hardening phenomenon in strain-hardened MP35N alloy10.1016/S1359-6454(98)00235-3 ↗
16. Ripple structure of crystalline layers in ion-beam-induced Si wafers10.1103/PhysRevB.70.121307 ↗
17. A mechanism of surface micro-roughening by ion bombardment10.1007/BF00754888 ↗
18. Structural investigation of keV Ar-ion-induced surface ripples in Si by cross-sectional transmission electron microscopy10.1103/PhysRevB.67.205403 ↗
19. Atomic force microscopy study of 60-keV Ar-ion-induced ripple patterns on Si(100)10.1103/PhysRevB.69.235313 ↗
20. Chapman · 1980
21. Plasma-induced alignment of carbon nanotubes10.1063/1.1306658 ↗
22. Wilson · 1973
23. Massalski TB, Okamoto H, Subramanian PR, Kacprzrak L. Binary alloy phase diagrams. 2nd ed. Materials Park, OH:ASM International; 1990.
24. Significantly accelerated osteoblast cell growth on aligned TiO2 nanotubes10.1002/jbm.a.30722 ↗
25. Stem cell fate dictated solely by altered nanotube dimension10.1073/pnas.0813200106 ↗
26. Enhanced cellular mobility guided by TiO2 nanotube surfaces10.1021/nl072572o ↗