journal article·2009-11

Radio-opaque bioactive glass markers for radiostereometric analysis

Rami Madanat, Niko Moritz, Erik Vedel, Erkki Svedström, Hannu T. Aro

Acta Biomaterialia· Volume 5· Issue 9
Publisher page

Abstract

The objective of the study was to test the hypothesis that resorbable radio-opaque bioactive glass markers can be used in radiostereometric analysis (RSA). Cones made from (1) bioactive glass 1-06 with 2.5 wt.% BaSO(4), (2) glass 1-06 with 10 wt.% BaSO(4), (3) glass 1-06 without any additives and (4) nearly inert glass were created. The in vitro surface reactivity, as a surrogate of bioactivity, was analyzed using a simulated body fluid (SBF) immersion test. The in vivo performance was evaluated in the rat femur using biomechanical testing as well as histological and microcomputed tomography analysis of marker incorporation into bone. A phantom model RSA study using a porcine radius with a soft tissue envelope was carried out to determine the accuracy and precision of spherical markers for the measurement of fracture micromotion. SBF immersion studies and bone implantation studies showed that the addition of BaSO(4) slightly reduced surface reactivity in vitro and the bone-bonding properties of the bioactive glass in vivo. In the simulated RSA study with the selected resorbable marker composition (bioactive glass with 10 wt.% BaSO(4)), the accuracy of translation and rotation measurements in the longitudinal axis was +/-51 microm and +/-0.87 degrees , respectively. The precision of translation and rotation measurements in the longitudinal axis were 9 microm and 0.18 degrees , respectively. Bioactive glass markers with BaSO(4) additive appear to have adequate bone-bonding properties for marker stability and sufficient radio-opacity for RSA, but further preclinical comparison studies with tantalum markers are necessary.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Facial Trauma and Fracture Management · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Assessment of fragment micromotion in distal femur fracture fixation with RSA10.1097/01.blo.0000224008.19798.91 ↗
2. The history and future of radiostereometric analysis10.1097/01.blo.0000224001.95141.fe ↗
3. Standing versus supine radiographs in RSA evaluation of femoral head penetration10.1097/01.blo.0000224012.50292.67 ↗
4. Model-based RSA of a femoral hip stem using surface and geometrical shape models10.1097/01.blo.0000224010.04551.14 ↗
5. Radiostereometry of hip prostheses: review of methodology and clinical results
6. Peripheral quantitative computed tomography in evaluation of bioactive glass incorporation with bone10.1016/j.biomaterials.2005.04.033 ↗
7. Influence of the radiopacifier in an acrylic bone cement on its mechanical, thermal, and physical properties: barium sulfate-containing cement versus iodine-containing cement10.1002/jbm.b.30176 ↗
8. Vedel E. Predicting the properties of bioactive glasses. Dissertation, Åbo Akademi University; 2008. p. 73
9. Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W10.1002/jbm.820240607 ↗
10. How useful is SBF in predicting in vivo bone bioactivity10.1016/j.biomaterials.2006.01.017 ↗
11. Bioactive glasses
12. Mechanical verification of soft-tissue attachment on bioactive glasses and titanium implants10.1016/j.actbio.2008.02.012 ↗
13. Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro models10.1016/S0736-0266(01)00039-0 ↗
14. Accuracy and precision of radiostereometric analysis in the measurement of three-dimensional micromotion in a fracture model of the distal radius10.1016/j.orthres.2004.07.002 ↗
15. Guidelines for standardization of radiostereometry (RSA) of implants10.1080/17453670510041574 ↗
16. Effect of zoledronic acid on incorporation of a bioceramic bone graft substitute10.1016/j.bone.2005.09.016 ↗
17. Bone healing response to an injectable calcium phosphate cement with enhanced radiopacity10.1002/jbm.b.30987 ↗
18. Assessment of inducible fracture micromotion in distal radial fractures using radiostereometry10.1097/BOT.0b013e3181839669 ↗
19. Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses. A comparison of conventional measurements10.1302/0301-620X.83B5.10575 ↗
20. Characterization of bioactive glass coatings on titanium substrates produced using a CO2 laser10.1023/B:JMSM.0000032819.64994.42 ↗