Microneedle-based minimally-invasive measurement of puncture resistance and fracture toughness of sclera
Source abstract
Abstract
Unlabelled The sclera provides the structural support of the eye and protects the intraocular contents. Since it covers a large portion of the eye surface and has relatively high permeability for most drugs, the sclera has been used as a major pathway for drug administration. Recently, microneedle (MN) technology has shown the possibility of highly local and minimally-invasive drug delivery to the eye by MN insertion through the sclera or the suprachoroidal space. Although ocular MN needs to be inserted through the sclera, there has been no systematic study to understand the mechanical properties of the sclera, which are important to design ocular MNs. In this study, we investigated a MN-based method to measure the puncture resistance and fracture toughness of the sclera. To reflect the conditions of MN insertion into the sclera, force-displacement curves obtained from MN-insertion tests were used to estimate the puncture resistance and fracture toughness of sclera tissue. To understand the effect of the insertion conditions, dependency of the mechanical properties on insertion speeds, pre-strain of the sclera, and MN sizes were analyzed and discussed. Statement of significance Measurement of mechanical property of soft biological tissue is challenging due to variations between tissue samples or lack of well-defined measurement techniques. Although non-invasive measurement techniques such as nano/micro indentation were employed to locally measure the elastic modulus of soft biological materials, mechanical properties such as puncture resistance or fracture toughness, which requires "invasive" measurement and is important for the application of "microneedles or hypodermic needles", has not been well studied. In this work, we report minimally-invasive measurement of puncture resistance and fracture toughness of sclera using a double MN insertion method. Parametric studies showed that use of MN proved to be advantageous because of minimally-invasive insertion into tissue as well as higher sensitivity to sub-tissue architecture during the measurement.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advancements in Transdermal Drug Delivery · Ocular Surface and Contact Lens · Advanced Drug Delivery Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Ocular drug delivery10.1208/s12248-010-9183-3 ↗
2. Drug delivery to the posterior segment of the eye10.1016/j.drudis.2010.12.004 ↗
3. Coated microneedles for drug delivery to the eye10.1167/iovs.07-0066 ↗
4. Intrascleral drug delivery to the eye using hollow microneedles10.1007/s11095-008-9756-3 ↗
5. Microneedle-mediated intrascleral delivery of in situ forming thermoresponsive implants for sustained ocular drug delivery10.1111/jphp.12152 ↗
6. Suprachoroidal drug delivery to the back of the eye using hollow microneedles10.1007/s11095-010-0271-y ↗
7. Targeted administration into the suprachoroidal space using a microneedle for drug delivery to the posterior segment of the eye microneedle use for targeted drug delivery10.1167/iovs.12-9872 ↗
8. Fatt · 2013
9. Scleral structure, organisation and disease10.1016/S0014-4835(03)00212-4 ↗
10. Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force10.1016/j.jbiomech.2003.12.010 ↗
11. Titanium-based, fenestrated, in-plane microneedles for passive ocular drug delivery
12. A comparison of the elastic properties of human choroid and sclera10.1016/0014-4835(88)90053-X ↗
13. Regional variation in the biomechanical properties of the human sclera10.1016/j.exer.2010.02.010 ↗
14. Age-related variations in the biomechanical properties of human sclera10.1016/j.jmbbm.2012.10.011 ↗
15. Measurement of the fracture toughness of extensible connective tissues10.1007/BF00540731 ↗
16. Ranking the fracture toughness of thin mammalian soft tissues using the scissors cutting test10.1016/S0021-9290(96)00101-7 ↗
17. On the sharpness of straight edge blades in cutting soft solids: Part I–indentation experiments10.1016/j.engfracmech.2006.10.015 ↗
18. Evaluation of fracture toughness of cartilage by micropenetration
19. Estimation of the fracture toughness of soft tissue from needle insertion
20. Detailed finite element modelling of deep needle insertions into a soft tissue phantom using a cohesive approach10.1080/10255842.2011.628448 ↗
21. Mechanics of dynamic needle insertion into a biological material10.1109/TBME.2009.2036856 ↗
22. Estimation of fracture toughness of liver tissue: experiments and validation10.1016/j.medengphy.2011.09.030 ↗
23. Biaxial mechanical testing of human sclera10.1016/j.jbiomech.2010.02.031 ↗
24. Measurements of the compressive properties of scleral tissue
25. Transscleral drug delivery for posterior segment disease10.1016/S0169-409X(01)00193-4 ↗
26. The fracture toughness of soft tissues10.1016/j.jmbbm.2011.09.018 ↗
27. Experimental investigation into the deep penetration of soft solids by sharp and blunt punches, with application to the piercing of skin10.1115/1.1992528 ↗
28. Physiopathologic aspects of scleral stress-strain
29. Treatment of acute posterior uveitis in a porcine model by injection of triamcinolone acetonide into the suprachoroidal space using microneedles triamcinolone in the suprachoroidal space10.1167/iovs.13-11747 ↗
30. Porcine sclera: thickness and surface area
31. Trajectory optimization for dynamic needle insertion
32. Atkins · 1985
33. Dynamic delamination fracture toughness in unidirectional polymeric composites10.1016/S0266-3538(00)00197-4 ↗