Modified PMMA cements for a hydrolysis resistant metal–polymer interface in orthopaedic applications
Source abstract
Abstract
Amongst the many factors influencing the long-term stability of cemented hip prostheses, the interface between the implant and bone cement is considered to be one of the most susceptible to failure. Osteolysis and loosening of the implant can occur by the interaction of mechanically and/or hydrolytically induced bond failure of the metal-cement interface. In this work, an improvement of the hydrolysis resistance of the titanium-bone cement interface was obtained by cement modification with a bifunctional coupling agent combined with a tribochemical TiO2-modification of the metal surface. Methacryloxypropyl-trimethoxysilane was added as coupling agent to the PMMA monomer in concentrations between 5 and 20 wt.% followed by the testing the shear bond strength of PMMA/titanium joints before and after ageing in physiological saline solution. It was found that the hydrolysis resistance of the metal-PMMA interface could be significantly improved by the modification of the cement. At the same time, the mechanical properties (compressive and bending strength) of the modified cement were not altered by the addition of the coupling agent. The advantage of the modification of the cement matrix is an easy clinical applicability of the procedure maintaining the processing and implantation techniques of the cement material.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Combustion and flame dynamics · Advanced Combustion Engine Technologies · Vehicle emissions and performance
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Bone cements based on polymethylmethacrylate10.1007/s00132-002-0411-0 ↗
2. The science of bone cement: a historical review10.3928/0147-7447-20021201-21 ↗
3. Analysis of long-term cemented total hip arthroplasty retrievals10.1097/00003086-200212000-00009 ↗
4. Interfacial tensile bonding strength of the cement–prosthesis interface10.3928/0147-7447-19940201-12 ↗
5. Do we need to vacuum mix or centrifuge cement?10.1097/00003086-199212000-00013 ↗
6. In vitro and in vivo studies of pressurization of femoral cement in total hip arthroplasty10.1016/0883-5403(93)90004-N ↗
7. Effects of fatigue loading and PMMA precoating on the adhesion and subcritical debonding of prosthetic–PMMA interfaces10.1002/(SICI)1097-4636(200008)51:2<172::AID-JBM5>3.0.CO;2-Y ↗
8. Is it advantageous to strengthen the cement–metal-interface and use a collar for cemented femoral components of total hip replacements?10.1097/00003086-199212000-00011 ↗
9. Cemented fixation with PMMA or bis-GMA resin hydroxyapatite cement: effect of implant surface roughness10.1016/j.biomaterials.2003.12.020 ↗
10. The effect of a thin coating of polymethylmethacrylate on the torsional fatigue-strength of the cement–metal interface10.1002/jab.770030108 ↗
11. Loosening rates and bone lysis with rough finished and polished stems10.1097/00003086-199810000-00012 ↗
12. A titanium alloy implant with a corundum blast finish—results at a mean 6 years in a prospective study10.1016/S0883-5403(96)80080-5 ↗
13. Long-term results of cemented femoral stems with roughened precoated surfaces10.1097/00003086-199810000-00014 ↗
14. Bond strength of silicoated and acrylic resin bonding systems to metal
15. Resin-metal bonding systems: a review of the silicoating and Kevloc systems
16. The effect of a silane coupling agent on the bond strength of bone cement and cobalt–chrome alloy10.1002/(SICI)1097-4636(200001)49:1<127::AID-JBM16>3.0.CO;2-G ↗
17. Tribochemical structuring and coating of implant metal surfaces with titaniumoxide and hydroxyapatite-layers10.1016/S0928-4931(02)00322-3 ↗
18. Oberflächenmodifikation von Dentallegierungen mit tribochemischen TiO2 Beschichtungen10.1515/bmte.1995.40.s1.35 ↗
19. The initiation of failure in cemented femoral components of hip arthroplasties10.1302/0301-620X.73B4.2071634 ↗
20. Thin film PMMA precoating for improved implant bone–cement fixation10.1002/jbm.820160515 ↗
21. Some factors affecting the strength of the cement–metal interface10.1302/0301-620X.71B2.2925738 ↗
22. Enhanced strength in cemented stem fixation using adhesive acrylic cement as a metal coating material10.1002/(SICI)1097-4636(199702)34:2<171::AID-JBM5>3.0.CO;2-N ↗
23. Silane to enhance the bond between polymethyl methacrylate and titanium10.1016/S0022-3913(05)80070-8 ↗
24. Musil · 1989
25. In vivo evaluation of the bond strength of adhesive 4-META/MMA–TBB bone cement under weight bearing conditions10.1002/1097-4636(200010)52:1<128::AID-JBM16>3.0.CO;2-L ↗
26. An investigation of debonding between heat cured PMMA and titanium alloy (Ti–6Al–4V)10.1016/S0300-5712(96)00051-6 ↗
27. Influence of surface treatment on adherence energy of alloys used in bonded prosthetics10.1046/j.1365-2842.1999.00388.x ↗
28. Block copolymers of gamma-methacryloxypropyltrimethoxysilane and methyl methacrylate by RAFT polymerization. A new class of polymeric precursors for the sol–gel process10.1021/ma048143j ↗
29. Tribochemische TiO2-beschichtungen auf dentallegierungen
30. ABCR gelest catalogue, Karlruhe, Germany 2004, p. 308.
31. Bioactive PMMA bone cement prepared by modification with methacryloxypropyltrimethoxy–silane and calcium chloride10.1002/jbm.a.20042 ↗
32. Development of bioactive PMMA-based cement by modification with alkoxysilane and calcium salt10.1023/A:1012876108210 ↗