journal article·2014-05

Controlled metallic nanopillars for low impedance biomedical electrode

Calvin J. Gardner, Jonathan Trisnadi, Tae Kyoung Kim, Karla Brammer, Lina Reiss, Li-han Chen, Sungho Jin

Acta Biomaterialia· Volume 10· Issue 5
Publisher page

Abstract

Radial metallic nanopillar/nanowire structures can be created by a controlled radiofrequency (RF) plasma processing technique on the surface of certain alloy wires, including important biomedical alloys such as MP35N (Co-Ni-Cr-Mo alloy), platinum-iridium and stainless steel. In electrode applications such as pacemakers or neural stimulators, the increase in surface area in elongated MP35N nanopillars allows for decreased surface impedance and greater current density. However, the nanopillar height on MP35N alloy tends to be self-limiting at ∼1-3μm. The objective of this study was to further elongate the radial nanopillars so as to reduce electrode impedance for biomedical electrode applications. Intelligent experimental design allowed for efficient investigation of processing parameters, including plasma material, process duration, power, pressure and repetition. It was found that multi-step repeated processing in the parameter-controlled RF environment could increase nanopillar height to ∼10μm, a 400% improvement, while the RF plasma processing with identical total duration but in a single step did not lead to desired nanopillar elongation. Measurement of electrode impedance in phosphate-buffered saline solution showed an associated decrease to one-fifth of the surface impedance of unprocessed wire for signals below 100Hz. For the purposes of this study, MP35N and Pt-Ir wires were characterized and demonstrated augmented surface impedance properties which, in combination with superior cell integration, enhanced biomedical electrode performance.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Neuroscience and Neural Engineering · Advanced Memory and Neural Computing · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Chronic electrical stimulation of the auditory nerve using high surface area (HiQ) platinum electrodes10.1016/S0378-5955(01)00320-3 ↗
2. Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance10.1097/00003446-200202001-00004 ↗
3. High impedance low energy pacing leads: long-term results with a very small surface area steroid-eluting lead compared to three conventional electrodes10.1111/j.1540-8159.1999.tb00446.x ↗
4. Failure of demand pacing with small surface area electrodes10.1161/01.CIR.54.1.128 ↗
5. Decreasing electrode size and increasing efficiency of cardiac stimulation10.1016/0022-4804(71)90032-1 ↗
6. A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users10.1097/00003446-200112000-00004 ↗
7. Impedance characterization and modeling of electrodes for biomedical applications10.1109/TBME.2005.847523 ↗
8. Characteristics of the metal–tissue interface of stimulation electrodes10.1109/TBME.1976.324585 ↗
9. The electrode–tissue interface in living heart: equivalent circuit as a function of surface area10.1002/(SICI)1521-4109(199804)10:4<262::AID-ELAN262>3.0.CO;2-W ↗
10. On porous electrodes in electrolyte solutions. I. Capacitance effects10.1016/0013-4686(63)80042-0 ↗
11. Electrical properties of platinum electrodes: impedance measurements and time-domain analysis10.1007/BF02442925 ↗
12. Electrode polarization impedance and measurements in biological materials10.1111/j.1749-6632.1968.tb20349.x ↗
13. Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes10.1016/S0924-4247(01)00637-9 ↗
14. Surface modification of neural recording electrodes with conducting polymer/biomolecule blends10.1002/1097-4636(200108)56:2<261::AID-JBM1094>3.0.CO;2-I ↗
15. Investigation of interfacial capacitance of Pt, Ti and TiN coated electrodes by electrochemical impedance spectroscopy10.1016/S1389-0344(02)00013-8 ↗
16. Radially arrayed nanopillar formation on metallic stent wire surface via radio-frequency plasma10.1016/j.actbio.2009.11.015 ↗
17. Plasma-induced nanopillars on bare metal coronary stent surface for enhanced endothelialization10.1016/j.actbio.2010.07.007 ↗
18. Characterization of cold-rolled and aged MP35N alloys10.1016/S1044-5803(01)00162-0 ↗
19. The Ir–Pt (iridium–platinum) system10.1007/BF02645356 ↗
20. A mechanism of surface micro-roughening by ion bombardment10.1007/BF00754888 ↗
21. Plasma potentials of 13.56-MHz rf argon glow discharges in a planar system10.1063/1.335396 ↗
22. Using fractional factorial designs for robust process development10.1080/08982119008918849 ↗
23. Study of influence of electrode geometry on impedance spectroscopy10.1016/S1452-3981(23)15064-4 ↗