Protein-metal interactions due to fretting corrosion at the taper junction of hip implants: An in vitro investigation using Raman spectroscopy
Source abstract
Abstract
Modular hip implants are a clinically successful and widely used treatment for patients with arthritis. Despite ongoing retrieval studies the understanding of the fundamental physico-chemical mechanisms of friction and wear within the head-taper interface is still limited. Here, we Raman-spectroscopically analyze structural features of the biotribological material which is formed within the taper joint between Ti6Al4V and low-carbon cobalt alloy or high-nitrogen steel surfaces in in vitro gross-slip fretting corrosion tests with bovine calf serum. As a function of the fretting duration, we investigate short and long aliphatic chains and their adsorption behavior on the cobalt- and steel-type surfaces. Using the intensity and frequency shifts of the amide I and III Raman bands, we furthermore identify progressive protein folding and unfolding including the secondary structures of α -helix, β -sheet, and random-coil configuration as well as the formation of proteinaceous clusters depending on the hydrophilicity of the metallic surfaces. We additionally find a mixture of chromates and iron oxides with tryptophan and tyrosine at the worn cobalt alloy and high-nitrogen steel surfaces, respectively. Also, for long fretting duration, sp 2 hybridized amorphous carbon is formed due to fretting-induced cleavage of proteins. Despite efforts enhancing the biomedical tribology of hip implants, the impact of the organic environment on friction&wear at the femoral head-stem taper interface is limitedly understood. Using Raman spectroscopy we resolve structural changes within the biotribological material agglomerated at biomedical-grade metal alloys due to organo-metallic interactions during in vitro fretting corrosion tests. Adsorption of short and long aliphatic chains, progressive protein (un)folding and proteinaceous cluster formation depend to a distinguishable extent on the fretting duration and type of alloy. Chromates and iron oxides are mixed with tryptophan and tyrosine, and amorphous carbon is formed resulting from a fretting-induced cleavage of serum proteins. Such information spectroscopically gleaned from biotribological material are vital to improve the design and performance of taper junctions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (94)
Show source-provided references
1. Prevalence of total hip and knee replacement in the united states10.2106/JBJS.N.01141 ↗
2. Rates of total joint replacement in the united states: future projections to 2020–2040 using the national inpatient sample10.3899/jrheum.170990 ↗
3. Hip and knee replacement in germany and the usa
4. Total hip replacement due to osteoarthritis: the importance of age, obesity, and other modifiable risk factors10.1016/S0002-9343(02)01447-X ↗
5. Modular neck femoral stems10.1302/0301-620X.95B8.31525 ↗
6. Micromotions at the taper interface between stem and neck adapter of a bimodular hip prosthesis during activities of daily living10.1002/jor.22354 ↗
7. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. the effect of crevice, stress, motion, and alloy coupling10.1002/jbm.820271210 ↗
8. Fretting corrosion accelerates crevice corrosion of modular hip tapers10.1002/jab.770060104 ↗
9. Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: an in vitro study10.1002/jor.23601 ↗
10. Migration of corrosion products from modular hip prostheses. particle microanalysis and histopathological findings10.2106/00004623-199409000-00009 ↗
11. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M ↗
12. Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time10.1243/09544119JEIM112 ↗
13. Topography rules the ultra-mild wear regime under boundary lubricated gross-slip fretting corrosion10.1016/j.wear.2023.204716 ↗
14. Atomic scale origin of metal ion release from hip implant taper junctions
15. Differential lymphocyte reactivity to serum-derived metal-protein complexes produced from cobalt-based and titanium-based implant alloy degradation10.1002/1097-4636(20010905)56:3<427::AID-JBM1112>3.0.CO;2-E ↗
16. CoCrMo metal-on-metal hip replacements10.1039/C2CP42968C ↗
17. Survivorship and retrieval analysis of sikomet metal-on-metal total hip replacements at a mean of seven years10.2106/JBJS.E.00604 ↗
18. Loosening and osteolysis associated with metal-on-metal bearings: a local effect of metal hypersensitivity?
19. A servoelectric apparatus with potentiostat to study the fretting corrosion of cobalt-chromium-titanium alloy couples
20. The influence of molybdenum on the fretting corrosion behavior of CoCr/TiAlV couples10.1016/j.biotri.2017.01.001 ↗
21. The mechanism-based approach of understanding run-in and steady state: a gross-slip fretting experiment to fathom tribocorrosion of total hip taper junctions10.1016/j.biotri.2021.100165 ↗
22. Fretting-corrosion of CoCr-alloys against TiAl6V4: the importance of molybdenum in oxidative biological environments10.1016/j.wear.2021.203813 ↗
23. The gross slip fretting corrosion mechanisms of biomedical ceramic-metal couples
24. Degradation modes of CoCrMo and ti6al4valloys in modular head-neck junctions of retrieved hip prostheses
25. Nickel-free high-nitrogen austenitic steel outperforms CoCrMo alloy regarding tribocorrosion in simulated inflammatory synovial fluids10.1002/jor.25174 ↗
26. Biomaterials in orthopedic surgery: effects of a nickel-reduced stainless steel on in vitro proliferation and activation of human osteoblasts10.1177/039139880302601013 ↗
27. A new austenitic stainless steel with a negligible amount of nickel: an in vitro study in view of its clinical application in osteoporotic bone10.1002/jbm.b.30068 ↗
28. P2000 - a high-nitrogen austenitic steel for application in bone surgery10.1371/journal.pone.0214384 ↗
29. The tribological difference between biomedical steels and CoCrMo-alloys10.1016/j.jmbbm.2012.01.007 ↗
30. Probing three-dimensional structure of bovine serum albumin by chemical cross-linking and mass spectrometry10.1016/j.jasms.2004.05.004 ↗
31. Fetal bovine serum
32. Defined media and supplements
33. Effect of the bias voltage on the structural and tribo-mechanical properties of ag-containing amorphous carbon films10.1016/j.diamond.2020.107803 ↗
34. Raman scattering study of micrometer-sized spots of magnetite and hematite formed at 18CrNiMo7-6 screw rotor surfaces due to liquid-free, unsynchronized operation10.1088/1757-899X/425/1/012016 ↗
35. Investigation of the tribofilm formation of HiPIMS sputtered MoSx thin films in different environments by raman scattering10.3390/lubricants7110100 ↗
36. Optical constants of transition metals: Ti, V, Cr, Mn, Fe, Co, Ni, and Pd10.1103/PhysRevB.9.5056 ↗
37. Resonant plasmonic–biomolecular chiral interactions in the far-ultraviolet: enantiomeric discrimination of sub-10 nm amino acid films10.1021/acs.nanolett.2c01724 ↗
38. Refractive indices for amorphous carbon10.1086/162727 ↗
39. Performance of austenitic high-nitrogen steels under gross slip fretting corrosion in bovine serum10.3390/jfb15040110 ↗
40. The evolution of tribomaterial during sliding: abrief introduction10.1007/s11249-009-9498-3 ↗
41. Structural and immunologic characterization of bovine, horse, and rabbit serum albumins10.1016/j.molimm.2012.05.011 ↗
42. Vibrational analysis of amino acids and short peptides in hydrated media. VIII. amino acids with aromatic side chains: L-phenylalanine, l-tyrosine, and l-tryptophan10.1021/jp106786j ↗
43. Characteristic raman lines of phenylalanine analyzed by a multiconformational approach10.1002/jrs.4290 ↗
44. The effect of disulfide bonds on protein folding, unfolding, and misfolding investigated by FT-raman spectroscopy10.1002/jrs.4935 ↗
45. Tryptophan tight binding to gold nanoparticles induces drastic changes in indole ring raman markers10.1021/acs.jpcc.8b02261 ↗
46. All characteristic raman markers of tyrosine and tyrosinate originate from phenol ring fundamental vibrations10.1002/jrs.4776 ↗
47. S–S and C–S stretching vibrations and molecular conformations of dialkyl disulfides and cystine10.1246/cl.1972.83 ↗
48. Conformational differences in protein disulfide linkages between normal hair and hair from subjects with trichothiodystrophy: a quantitative analysis by raman microspectroscopy10.1002/bip.20515 ↗
49. Conformational changes in seventeen cystine disulfide bridges of bovine serum albumin proved by raman spectroscopy10.1016/S0014-5793(97)01326-4 ↗
50. Raman spectroscopy of lipids: a review10.1002/jrs.4607 ↗
51. The raman spectra of Cr3O8 and Cr2O510.1002/jrs.687 ↗
52. Raman microscopy of selected chromate minerals10.1002/jrs.1121 ↗
53. Pressure-induced structural phase transition in CaCrO4: evidence from raman scattering studies10.1063/1.2117624 ↗
54. Surface-enhanced raman spectroelectrochemical studies of corrosion films on implant Co–Cr–Mo alloy in biosimulating solutions10.1002/(SICI)1097-4555(199902)30:2<97::AID-JRS352>3.0.CO;2-X ↗
55. Raman spectral study on the solution structure of the chromium(iii)-edta complex10.1021/ic00240a041 ↗
56. Reactivity of CoCrMo alloy in physiological medium: electrochemical characterization of the metal/protein interface10.1016/j.electacta.2008.01.025 ↗
57. Normal coordinate analysis of the indole ring10.1016/0584-8539(86)80021-6 ↗
58. Raman structural markers of tryptophan and histidine side chains in proteins10.1002/bip.10440 ↗
59. Raman spectroscopy of proline oligomers and poly-l-proline10.1021/ja00728a034 ↗
60. Raman studies of bovine serum albumin10.1002/bip.1976.360150114 ↗
61. Laser-excited raman spectroscopy of biomolecules. viii. conformational study of bovine serum albumin10.1021/ja00420a021 ↗
62. Raman spectroscopic analysis of high molecular weight proteins in solution – considerations for sample analysis and data pre-processing10.1039/C8AN01701H ↗
63. Raman spectroscopic signatures of carotenoids and polyenes enable label-free visualization of microbial distributions within pink biofilms10.1038/s41598-020-64737-3 ↗
64. Surface enhanced hyper-raman scattering of the amino acids tryptophan, histidine, phenylalanine, and tyrosine10.1021/acs.jpcc.6b10905 ↗
65. Probing the stepwise unfolding of bovine serum albumin using 2d correlation raman spectroscopic analysis10.1021/acs.analchem.0c02968 ↗
66. Socrates · 2001
67. Micro-raman spectroscopy used to identify and grade human skin pilomatrixoma10.1002/jemt.20229 ↗
68. Laser raman spectroscopy study of bovine fibrinogen and fibrin10.1016/0005-2795(79)90118-1 ↗
69. Identification and quantification of valuable plant substances by ir and raman spectroscopy10.1016/j.vibspec.2006.06.001 ↗
70. The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt–chromium and zirconia balls10.1016/S0142-9612(03)00148-0 ↗
71. A spectroscopic approach of ph effect on thermal denaturation of human and bovine serum albumins
72. Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses10.1002/jbm.b.31671 ↗
73. Structure of pressure-induced denatured state of human serum albumin: a comparison with the intermediate in urea-induced denaturation10.1016/S0167-4838(96)00175-6 ↗
74. Albumin adsorption on CoCrMo alloy surfaces10.1038/srep18403 ↗
75. Tribological behavior of CoCrMo artificial knee joint with symmetrically biomimetic textured surfaces on PEEK10.1016/j.optlastec.2022.108774 ↗
76. Dominant forces in protein folding10.1021/bi00483a001 ↗
77. Study on wear reduction mechanisms of artificial cartilage by synergistic protein boundary film formation10.1299/jsmec.48.555 ↗
78. Competitive adsorption of human serum albumin and gamma-globulin from a binary protein mixture onto hexadecyltrichlorosilane coated glass10.1163/156856298X00488 ↗
79. Ratiometric analysis using raman spectroscopy as a powerful predictor of structural properties of fatty acids10.1098/rsos.181483 ↗
80. Study of colombian coals using photoacoustic fourier transform infrared spectroscopy10.1016/j.coal.2010.12.013 ↗
81. Electronegativity values from thermochemical data10.1016/0022-1902(61)80142-5 ↗
82. PEG-immobilized keratin for protein drug sequestration and pH-mediated delivery10.1155/2016/7843951 ↗
83. Influence of chain length on the diffusion and electrophoresis of DNA adsorbed on heterogeneous supported lipid bilayers10.1021/la101679n ↗
84. Fundamentals of protein and cell interactions in biomaterials
85. Surface diffusion of interacting proteins. effect of concentration on the lateral mobility of adsorbed bovine serum albumin10.1016/S0006-3495(90)82473-5 ↗
86. Interpretation of raman spectra of disordered and amorphous carbon10.1103/PhysRevB.61.14095 ↗
87. Tuning of solid-to-solid structural transitions in amorphous carbon films by optical pumping and chemical modification10.1063/5.0138362 ↗
88. Graphitic tribological layers in metal-on-metal hip replacements10.1126/science.1213902 ↗
89. Interaction effects of cathode power, bias voltage, and mid-frequency on the structural and mechanical properties of sputtered amorphous carbon films10.1016/j.apsusc.2019.05.131 ↗
90. Diamond-like carbon coatings as biocompatible materials—an overview10.1016/S0925-9635(03)00018-9 ↗
91. Diamond like carbon coatings for potential application in biological implants—a review10.1016/j.triboint.2012.09.006 ↗
92. Structure and reactivity of water at biomaterial surfaces10.1016/S0001-8686(97)00040-7 ↗
93. The role played by modified bioinspired surfaces in interfacial properties of biomaterials10.1007/s12551-017-0306-2 ↗
94. Nickel-free high-nitrogen austenitic steel outperforms CoCrMo alloy regarding tribocorrosion in simulated inflammatory synovial fluids10.1002/jor.25174 ↗