Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty: An in vitro study
Source abstract
Abstract
Corrosion at the modular taper junctions in total hip arthroplasty is clinically relevant because wear particles and ions generated at this interface can lead to adverse local tissue reactions or even implant failure. In vitro tribo-corrosion tests are usually accomplished in saline solutions or calf serum (CS), but the addition of H2O2 and FeCl3 have been suggested to mimic inflammatory conditions in the joint. Inflammatory conditions may aggravate corrosive processes and, therefore, should lead in vitro to a more severe and realistic tribo-corrosive material attack. Corrosion testing at 12/14 tapers comprising a CoCrMo head taper and a Ti6Al4V trunnion was accomplished in five electrolytes (Ringer's solution (RS), RS with 30 mM H2O2 and/or 0.7 mM FeCl3 and CS) under dynamical loading for five million cycles. Resulting material loss was determined gravimetrically and by ion analysis. The tribo-corrosive material degradation was investigated by light and electron microscopy. FeCl3 enhanced the material loss from taper connections while H2O2 did not lead to a significant alteration of total material loss. In comparison to pure RS, corrosion testing in CS decreased material loss at the head taper while it increased material loss at the trunnion. The combination of FeCl3 and H2O2 led to an enhanced occurrence of micro cracks at the trunnion surface. Adding FeCl3 and optionally also H2O2 aggravates material loss in in vitro corrosion testing of taper junctions and leads to harsher and probably more realistic testing conditions. STATEMENT OF SIGNIFICANCE: Tribo-corrosive processes at taper connections in hip implants are complex and can lead to major clinical implications. Joint inflammation is assumed to aggravate taper corrosion in vivo, why FeCl3 and H2O2 have been proposed as additives to electrolytes to simulate inflammatory conditions in vitro. Often used fretting test setups, however, do not involve real taper geometries. Besides, testing is often accomplished in saline solutions or calf serum, which do not induce a clinically significant amount of corrosive material degradation. This study presents an approach to increase tribo-corrosive processes at realistic taper connections by adding FeCl3 and/or H2O2. Unlike H2O2, FeCl3 increased material loss from taper connections. The combination of both additives enhanced micro crack formation at the trunnion surfaces.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty10.2106/JBJS.K.01352 ↗
2. What surgeons need to know about adverse local tissue reaction in total hip arthroplasty10.1016/j.arth.2020.01.016 ↗
3. MRI, retrieval analysis, and histologic evaluation of adverse local tissue reaction in metal-on-polyethylene total hip arthroplasty10.1016/j.arth.2016.11.046 ↗
4. A case example and literature review of catastrophic wear before catastrophic failure: identification of trunnionosis and metallosis in metal-on-polyethylene hip arthroplasty prior to frank failure or fracture10.1007/s00590-018-2333-5 ↗
5. Head taper corrosion causing head bottoming out and consecutive gross stem taper failure in total hip arthroplasty10.1016/j.arth.2018.07.017 ↗
6. Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings10.1002/jor.22326 ↗
7. Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system10.1002/jor.22970 ↗
8. Retrieval analysis of metal and ceramic femoral heads on a single CoCr stem design10.1302/2046-3758.65.BJR-2016-0325.R1 ↗
9. Atomic scale origin of metal ion release from hip implant taper junctions
10. The mechanism-based approach of understanding run-in and steady state: a gross-slip fretting experiment to fathom tribocorrosion of total hip taper junctions10.1016/j.biotri.2021.100165 ↗
11. The evolution of subsurface micro-structure and tribo-chemical processes in cocrmo-ti6al4v fretting-corrosion contacts: what lies at and below the surface?10.1016/j.wear.2019.203095 ↗
12. In vitro fretting crevice corrosion damage of CoCrMo alloys in phosphate buffered saline: debris generation, chemistry and distribution10.1016/j.actbio.2020.07.052 ↗
13. ROS production in phagocytes: why, when, and where?10.1189/jlb.1012544 ↗
14. In vitro evidence for cell-accelerated corrosion within modular junctions of total hip replacements10.1002/jor.24447 ↗
15. Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces10.1016/j.actbio.2019.10.039 ↗
16. The effect of simulated inflammatory conditions and Fenton chemistry on the electrochemistry of CoCrMo alloy10.1002/jbm.b.33830 ↗
17. The effect of simulated inflammatory conditions and pH on fretting corrosion of CoCrMo alloy surfaces10.1016/j.wear.2017.08.011 ↗
18. Corrosion of titanium under simulated inflammation conditions: clinical context and in vitro investigations10.1016/j.actbio.2021.10.002 ↗
19. Biomechanical evaluation of the fatigue performance, the taper corrosion and the metal ion release of a dual taper hip prosthesis under physiological environmental conditions10.1016/j.biotri.2017.07.002 ↗
20. Accelerated fretting corrosion testing of modular necks for total hip arthroplasty
21. Effect of inflammatory conditions and H2O2 on bare and coated Ti–6Al–4V surfaces: Corrosion behavior, metal ion release and Ca-P formation under long-term immersion in DMEM10.1016/j.apsusc.2015.08.261 ↗
22. Microstructural aspects of Ti6Al4V degradation in H2O2-containing phosphate buffered saline10.1016/j.corsci.2021.109640 ↗
23. A synergistic effect of albumin and H2O2 accelerates corrosion of Ti6Al4V10.1016/j.actbio.2015.07.046 ↗
24. Fretting-corrosion of CoCr-alloys against TiAl6V4: the importance of molybdenum in oxidative biological environments10.1016/j.wear.2021.203813 ↗
25. In vitro simulation of fretting-corrosion in hip implant modular junctions: the influence of pH10.1016/j.medengphy.2017.10.016 ↗
26. Fretting-corrosion in hip taper modular junctions: the influence of topography and pH levels–an in-vitro study10.1016/j.jmbbm.2021.104443 ↗
27. Same same but different? 12/14 stem and head tapers in total hip arthroplasty10.1016/j.arth.2017.04.027 ↗
28. Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors10.1016/j.jbiomech.2019.109424 ↗
29. 2013
30. 2007
31. Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral head10.1515/BMT.2006.018 ↗
32. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements10.1002/jbm.b.33972 ↗
33. Imprinting and column damage on CoCrMo head taper surfaces in total hip replacements
34. Role of corrosion in taper failure and head disassociation in total hip arthroplasty of a single design10.1002/jor.24107 ↗
35. Corrosion behavior of pure titanium anodes in saline medium and their performance for humic acid removal by electrocoagulation10.1016/j.chemosphere.2019.125674 ↗
36. Surface-protein interactions on different stainless steel grades: effects of protein adsorption, surface changes and metal release10.1007/s10856-013-4859-8 ↗
37. Role of protein adsorption in the bio corrosion of metallic implants-a review10.1016/j.colsurfb.2019.01.038 ↗
38. The corrosion behaviour of Ti–6Al–4V, Ti–6Al–7Nb and Ti–13Nb–13Zr in protein solutions10.1016/S0142-9612(98)00217-8 ↗
39. Effect of proteins on the surface microstructure evolution of a CoCrMo alloy in bio-tribocorrosion processes10.1016/j.colsurfb.2016.05.002 ↗
40. The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections10.1016/j.medengphy.2012.07.013 ↗
41. A metal ion release study of CoCrMo exposed to corrosion and tribocorrosion conditions in simulated body fluids10.1016/j.wear.2014.12.030 ↗
42. Ceramic heads decrease metal release caused by head-taper fretting and corrosion10.1007/s11999-015-4683-1 ↗
43. Metal ion release after hip and knee arthroplasty-causes, biological effects and diagnostics10.1055/a-0929-8121 ↗
44. Taper corrosion: a complication of total hip arthroplasty10.1302/2058-5241.5.200013 ↗
45. 2003
46. 2009
47. 2009