In Vitro Corrosion Assessment of the Essure® Medical Device in Saline, Simulated Inflammatory Solution and Neutral Buffered Formalin

Can Aslan, Jeremy L. Gilbert

Acta Biomaterialia· Volume 147
Publisher page

Abstract

The Essure® permanent contraceptive implant, comprised of four alloys (nickel-titanium, 316L stainless steel, platinum-iridium, and tin-silver solder) and Dacron (PET) fibers, has been approved for use in the US for about two decades. However, little has been published on this implant's biomaterials performance, and as this implant gains interest in terms of in vivo performance, methods of implant post-retrieval storage also need to be assessed. This study investigated the electrochemical properties and ion release profile of Essure® during storage in phosphate buffered saline (PBS), 10 mM H2O2/PBS, a simulated inflammatory solution, and 10% neutral buffered formalin (NBF) to investigate the corrosion behavior and metal ion release. First, a galvanic test method was used to measure the galvanic interactions between alloys within the device. Second, an ion-release study over 107 days was performed. Ions were measured using inductively-coupled plasma mass spectrometry and the implants were assessed using digital optical microscopy, scanning electron microscopy, and energy dispersive x-ray spectrometry. The tin-silver (SnAg) solder continuously corroded in PBS and H2O2/PBS. In the presence of H2O2, nickel and titanium ions were released from the nickel-titanium (NiTi) coil, whereas release of these ions was minimal in PBS alone. Overall, corrosion of the SnAg solder, which holds the NiTi and 316L SS together, was significant in both PBS and H2O2/PBS and may result in loss of connection of the NiTi and 316L stainless steel portions of the implant. Storage in NBF exhibited very low corrosion rates for all alloys and low levels of ion release were observed indicating that formalin storage minimally affects the implant's corrosion status. STATEMENT OF SIGNIFICANCE: The Essure® device is an FDA premarket-approved female permanent sterilization device containing four different metal alloys and poly(ethylene terephthalate) polymer fibers. Significant concerns related to this device have been raised by the FDA since its introduction in 2002. This study is the first published in vitro work to specifically assess the corrosion mechanisms in this multi-alloy device and the role of different solution environments, including formalin storage, inorganic physiological saline and a simulated inflammatory condition. Significant evidence of corrosion of the tin-silver solder is documented, the release of Ni and Ti under simulated inflammatory conditions, and the relative inertness of storage of these implants in neutral buffered saline is presented. The tin-silver corrosion corroborates recent clinical evidence of tin corrosion products in tissues adjacent to these devices in vivo.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Anesthesia and Pain Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Experimental and Clinical Experiences with Double-velour Woven Dacron Prostheses10.1055/s-2007-1020373 ↗
2. Tissue response to the STOP microcoil transcervical permanent contraceptive device: results from a prehysterectomy study10.1016/S0015-0282(01)02858-8 ↗
3. Microinsert nonincisional hysteroscopic sterilization
4. Comparative corrosion behaviour of different Sn based solder alloys10.1007/s10854-014-2422-0 ↗
5. Corrosion of dental amalgams: electrochemical study of Ag–Hg, Ag–Sn and Sn–Hg phases10.1016/S0013-4686(01)00676-4 ↗
6. Chapter 27 - Wet Corrosion of Materials
7. Landolt · 2011 · 1
8. Preparation and characterization of electrophoretically deposited hydroxyapatite coatings on type 316L stainless steel10.1016/S0010-938X(02)00091-4 ↗
9. An investigation into TiN-coated 316L stainless steel as a bipolar plate material for PEM fuel cells10.1016/j.jpowsour.2006.12.034 ↗
10. The electrochemical characteristics of native Nitinol surfaces10.1016/j.biomaterials.2009.03.034 ↗
11. The electrochemical behavior of nitinol in simulated physiological solutions10.1002/jbm.a.31616 ↗
12. Comparative in vitro performances of bare Nitinol surfaces
13. U.S. Food and Drug Administration. “Problems Reported with Essure,” FDA, 2020-2021, www.fda.gov/medical-devices/essure-permanent-birth-control/problems-reported-essure. Last accessed July 2, 2021.
14. Identification of inorganic particles resulting from degradation of Essure® Implants: Study of 10 Cases10.1016/j.ejogrb.2020.04.036 ↗
15. Potential release of toxic metal elements from Essure ® device in symptomatic patients: First results of the Frech Ablimco cohort10.1016/j.ejogrb.2020.07.044 ↗
16. Confirmation of the systemic presence of time particles in fallopian tubes or uterine horns of Essure implant explanted patients: A study of 18 cases with the same pathological process10.1016/j.jtemb.2021.126891 ↗
17. Leaching of trace elements from biological tissue by formalin fixation10.1007/s12011-007-8051-1 ↗
18. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
19. The Effect of Simulated Inflammatory Solutions and Fenton Chemistry on the Electrochemistry of CoCrMo Alloy10.1002/jbm.b.33830 ↗
20. Assessing the corrosion behaviour of Nitinol for minimally-invasive device design10.3109/13645700009063052 ↗
21. Corrosion behavior of nitinol wires in body fluid environments10.1002/jbm.a.10099 ↗
22. Galvanic corrosion of nitinol under deaerated and aerated conditions