journal article·2021-12Open access

Membrane curvature and connective fiber alignment in guinea pig round window membrane

Miguel Arriaga, Daniel N. Arteaga, Dimitrios Fafalis, Michelle Yu, Xun Wang, Karen E. Kasza, Anil K. Lalwani, Jeffrey W. Kysar

Acta Biomaterialia· Volume 136

Abstract

The round window membrane (RWM) covers an opening between the perilymph fluid-filled inner ear space and the air-filled middle ear space. As the only non-osseous barrier between these two spaces, the RWM is an ideal candidate for aspiration of perilymph for diagnostics purposes and delivery of medication for treatment of inner ear disorders. Routine access across the RWM requires the development of new surgical tools whose design can only be optimized with a thorough understanding of the RWM's structure and properties. The RWM possesses a layer of collagen and elastic fibers so characterization of the distribution and orientation of these fibers is essential. Confocal and two-photon microscopy were conducted on intact RWMs in a guinea pig model to characterize the distribution of collagen and elastic fibers. The fibers were imaged via second-harmonic-generation, autofluorescence, and Rhodamine B staining. Quantitative analyses of both fiber orientation and geometrical properties of the RWM uncovered a significant correlation between mean fiber orientations and directions of zero curvature in some portions of the RWM, with an even more significant correlation between the mean fiber orientations and linear distance along the RWM in a direction approximately parallel to the cochlear axis. The measured mean fiber directions and dispersions can be incorporated into a generalized structure tensor for use in the development of continuum anisotropic mechanical constitutive models that in turn will enable optimization of surgical tools to access the cochlea. STATEMENT OF SIGNIFICANCE: The Round Window Membrane (RWM) is the only non-osseous barrier separating the middle and inner ear spaces, and thus is an ideal portal for medical access to the cochlea. An understanding of RWM structure and mechanical response is necessary to optimize the design of surgical tools for this purpose. The RWM geometry and the connective fiber orientation and dispersion are measured via confocal and 2-photon microscopy. A region of the RWM geometry is characterized as a hyperbolic paraboloid and another region as a tapered parabolic cylinder. Predominant fiber directions correlate well with directions of zero curvature in the hyperbolic paraboloid region. Overall fiber directions correlate well with position along a line approximately parallel to the central axis of the cochlea's spiral.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Connective tissue disorders research · Elasticity and Material Modeling · Tissue Engineering and Regenerative Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (99)

Show source-provided references
1. Anatomy and Physiology of Hearing
2. Microanatomic analysis of the round window membrane by white light interferometry and microcomputed tomography for mechanical amplification10.1097/MAO.0000000000000193 ↗
3. Neuroanatomy of the Auditory System
4. Pharmacologic and molecular therapies of the cochlear and vestibular labyrinths
5. The effect of round window membrane rupture on endolymphatic and perilymphatic pressures10.1007/BF00455312 ↗
6. M.V. Goycoolea, L. Lundman, Round window membrane. Structure function and permeability: A review, 1997. doi:10.1002/(SICI)1097-0029(19970201)36:3<201::AID-JEMT8>3.0.CO;2-R.10.1002/(SICI)1097-0029(19970201)36:3<201::AID-JEMT8>3.0.CO;2-R ↗
7. The human round window – a perilymph pressure regulator? On a novel mechanoreceptor-like neuron in the human round window membrane10.1080/16513860410018213 ↗
8. Optimisation of the round window opening in cochlear implant surgery in wet and dry conditions: impact on intracochlear pressure changes10.1007/s00405-016-3993-6 ↗
9. Clinical aspects of round window membrane permeability under normal and pathological conditions10.1080/000164801300366552 ↗
10. Permeability of the round window membrane is influenced by the composition of applied drug solutions and by common surgical procedures10.1097/MAO.0b013e31818658ea ↗
11. Microperforations significantly enhance diffusion across round window membrane10.1097/MAO.0000000000000629 ↗
12. Systematic review of intratympanic gentamicin in Meniere’s disease10.2310/7070.2003.13863 ↗
13. Intratympanic steroid injection for treatment of idiopathic sudden hearing loss10.1016/j.otohns.2005.05.015 ↗
14. Visualization of endolymphatic hydrops in patients with Meniere’s disease10.1097/MLG.0b013e31802c300c ↗
15. Magnetic resonance imaging of the inner ear in Meniere’s disease10.1016/j.otc.2010.06.001 ↗
16. Diagnostic value of the magnetic resonance imaging with intratympanic gadolinium administration (IT-gd MRI) versus audio-vestibular tests in menière’s disease: IT-gd MRI makes the difference10.1097/MAO.0000000000002082 ↗
17. Cochlear gene delivery through an intact round window membrane in mouse10.1089/104303401300042465 ↗
18. Inner ear delivery: challenges and opportunities10.1002/lio2.336 ↗
19. Inner ear gene delivery: vectors and routes
20. A dual wedge microneedle for sampling of perilymph solution via round window membrane10.1007/s10544-016-0046-2 ↗
21. Serrated needle design facilitates precise round window membrane perforation10.1002/jbm.a.35692 ↗
22. In-vitro perforation of the round window membrane via direct 3-d printed microneedles10.1007/s10544-018-0287-3 ↗
23. 3D-Printed Microneedles create precise perforations in human round window membrane in situ10.1097/MAO.0000000000002480 ↗
24. Anatomical and functional consequences of microneedle perforation of round window membrane10.1097/MAO.0000000000002491 ↗
25. Drug delivery device for the inner ear: ultra-sharp fully metallic microneedles10.1007/s13346-020-00782-9 ↗
26. Small molecule delivery across a perforated artificial membrane by thermoreversible hydrogel poloxamer 40710.1016/j.colsurfb.2019.06.030 ↗
27. Novel 3D-Printed hollow microneedles facilitate safe, reliable, and informative sampling of perilymph from guinea pig10.1016/j.heares.2020.108141 ↗
28. The impact of systemic versus intratympanic dexamethasone administration on the perilymph proteome
29. Hydrostatic fluid pressure in the vestibular organ of the guinea pig10.1007/s00405-011-1813-6 ↗
30. The relationship of the round window membrane to the cochlear aqueduct shown in three-dimensional imaging10.1016/j.heares.2005.06.004 ↗
31. Round Window Membrane as a Portal for Inner Ear Therapy
32. Ultrastructural studies of the round-window membrane of the cat10.1001/archotol.1987.01860060043013 ↗
33. The human round window membrane: an electron microscopic study10.1001/archotol.1984.00800270019005 ↗
34. Subepithelial fiber components of the round window membrane of the guinea pig: an ultrastructural and immunohistochemical study10.1159/000276723 ↗
35. Ultrastructural studies of the human round window membrane10.1001/archotol.1989.01860290043012 ↗
36. Zhang · 1999
37. Chapter 3 - Extracellular Matrix (ECM) Molecules
38. Chapter 11 - Structure and behavior of collagen fibers
39. Contribution of collagen and elastin fibers to the mechanical behavior of an abdominal connective tissue10.1016/j.jmbbm.2016.04.006 ↗
40. Chapter 7 - the mechanical role of collagen fibers in the Intervertebral Disc
41. Dynamic properties of human round window membrane in auditory frequencies running head: dynamic properties of round window membrane10.1016/j.medengphy.2012.05.003 ↗
42. Nondestructive analysis of mitral valve collagen fiber orientation
43. Remodelling of continuously distributed collagen fibres in soft connective tissues10.1016/S0021-9290(03)00082-4 ↗
44. Heart valve function: a biomechanical perspective10.1098/rstb.2007.2122 ↗
45. Mechanics of the mitral valve: a critical review, an in vivo parameter identification, and the effect of prestrain10.1007/s10237-012-0462-z ↗
46. On the defect tolerance of fetal membranes10.1098/rsfs.2019.0010 ↗
47. Full-field bulge test for planar anisotropic tissues: part I-Experimental methods applied to human skin tissue10.1016/j.actbio.2012.11.035 ↗
48. Full-field bulge test for planar anisotropic tissues: part II-A thin shell method for determining material parameters and comparison of two distributed fiber modeling approaches10.1016/j.actbio.2012.11.034 ↗
49. Collagen structure and mechanical properties of the human sclera: analysis for the effects of age10.1115/1.4029430 ↗
50. Collagen fiber architecture of bovine pericardium10.1097/00002480-199407000-00075 ↗
51. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations10.1098/rsif.2005.0073 ↗
52. Microstructural quantification of collagen fiber orientations and its integration in constitutive modeling of the porcine carotid artery10.1016/j.actbio.2016.01.030 ↗
53. Quantitative assessment of myocardial collagen with picrosirius red staining and circularly polarized light10.1007/BF00788278 ↗
54. Regional mechanics determine collagen fiber structure in healing myocardial infarcts10.1016/j.yjmcc.2012.02.012 ↗
55. Three-dimensional collagen fiber mapping and tractography of human uterine tissue using OCT10.1364/BOE.397041 ↗
56. The mechanical role of the cervix in pregnancy10.1016/j.jbiomech.2015.02.065 ↗
57. Collagen fiber orientation and dispersion in the upper cervix of non-pregnant and pregnant women10.1371/journal.pone.0166709 ↗
58. Chudley · 2006
59. Constitutive modelling of arteries10.1098/rspa.2010.0058 ↗
60. Invariant formulation for dispersed transverse isotropy in aortic heart valves: an efficient means for modeling fiber splay10.1007/s10237-005-0069-8 ↗
61. Modelling non-symmetric collagen fibre dispersion in arterial walls10.1098/rsif.2015.0188 ↗
62. A review of artifacts in histopathology10.4103/jomfp.JOMFP_125_15 ↗
63. A survey of methods for 3d histology reconstruction10.1016/j.media.2018.02.004 ↗
64. Second harmonic generation confocal microscopy of collagen type I from rat tendon cryosections10.1529/biophysj.106.093740 ↗
65. Imaging coronary artery microstructure using second-Harmonic and two-Photon fluorescence microscopy10.1529/biophysj.104.042887 ↗
66. Changes in the extracellular matrix surrounding human chronic wounds revealed by 2-photon imaging10.1111/iwj.12789 ↗
67. Ex vivo and in vivo second-harmonic-generation imaging of dermal collagen fiber in skin: comparison of imaging characteristics between mode-locked cr:forsterite and ti:sapphire lasers10.1364/AO.48.000D88 ↗
68. Autofluorescence multiphoton microscopy for visualization of tissue morphology and cellular dynamics in murine and human airways10.1038/labinvest.2016.69 ↗
69. Quantification of aortic and cutaneous elastin and collagen morphology in marfan syndrome by multiphoton microscopy10.1016/j.jsb.2014.07.003 ↗
70. Spectroscopic characterization and microscopic imaging of extracted and in situ cutaneous collagen and elastic tissue components under two-photon excitation10.1111/j.1600-0846.2009.00381.x ↗
71. Multiphoton autofluorescence imaging of intratissue elastic fibers10.1016/j.biomaterials.2004.02.059 ↗
72. 3-Dimensional Imaging of collagen using second harmonic generation10.1016/S1047-8477(02)00576-2 ↗
73. Fluorescent staining of elastic tissue with Rhodamine B and related xanthene dyes10.1007/BF00306012 ↗
74. Fiji: an open-source platform for biological-image analysis10.1038/nmeth.2019 ↗
75. J. Schindelin, C.T. Rueden, M.C. Hiner, K.W. Eliceiri, The Image J ecosystem: An open platform for biomedical image analysis, 2015. http://doi.wiley.com/10.1002/mrd.22489.10.1002/mrd.22489 ↗
76. Volume measurements in threedimensional microscopy10.1002/sca.4950160403 ↗
77. MeshLab: an open-source mesh processing tool
78. A signal processing approach to fair surface design
79. Bærentzen · 2012
80. Chudley · 1976
81. Self-intersections of offsets of quadratic surfaces: Part I, explicit surfaces10.1007/BF01198970 ↗
82. Microstructural and mechanical characterization of the layers of human descending thoracic aortas10.1016/j.actbio.2021.07.036 ↗
83. Quantitative assessment of collagen fibre orientations from two-dimensional images of soft biological tissues10.1098/rsif.2012.0339 ↗
84. An automated approach for three-dimensional quantification of fibrillar structures in optically cleared soft biological tissues10.1098/rsif.2012.0760 ↗
85. A constrained von Mises distribution to describe fiber organization in thin soft tissues10.1007/s10237-011-0326-y ↗
86. An intoroduction to the calculation of numerical spectrum analysis
87. On the use of windows for harmonic analysis with the discrete Fourier transform10.1109/PROC.1978.10837 ↗
88. A spatial filtering approach to texture analysis10.1016/0167-8655(85)90053-4 ↗
89. A fourier domain directional filtering method for analysis of collagen alignment in ligaments10.1109/TBME.1987.325980 ↗
90. Multidimensional partitions of unity and Gaussian terrains
91. Jean-Yves Tinevez, Directionality - ImageJ, 2020, (https://imagej.net/Directionality (Jan. 2019)).
92. Directional Statistics10.1002/9780470316979 ↗
93. Introductory Statistical Inference with the Likelihood Function10.1007/978-3-319-10461-4 ↗
95. Morphological changes in the round window membrane associated with haemophilus influenzae-induced acute otitis media in the chinchilla10.1016/j.ijporl.2016.06.049 ↗
96. Dynamic properties of human round window membrane in auditory frequencies running head: dynamic properties of round window membrane10.1016/j.medengphy.2012.05.003 ↗
97. Dynamic properties of round window membrane in guinea pig otitis media model measured with electromagnetic stimulation10.1016/j.heares.2013.01.001 ↗
98. Mechanical Aspects of the Round Window Stimulation10.1016/j.piutam.2017.08.039 ↗
99. Performance considerations of prosthetic actuators for round-window stimulation10.1016/j.heares.2009.11.009 ↗