Increasing temperature accelerates Ti-6Al-4V oxide degradation and selective dissolution: An Arrhenius-based analysis
Source abstract
Abstract
Ti-6Al-4V selective dissolution occurs in vivo on orthopedic implants as the leading edge of a pitting corrosion attack. A gap persists in our fundamental understanding of selective dissolution and pre-clinical tests fail to reproduce this damage. While CoCrMo clinical use decreases, Ti-6Al-4V and the crevice geometries where corrosion can occur remain ubiquitous in implant design. Additionally, most additively manufactured devices cleared by the FDA use Ti-6Al-4V. Accelerated preclinical testing, therefore, would aid in the evaluation of new titanium devices and biomaterials. In this study, using temperature, we (1) developed an accelerated pre-clinical methodology to rapidly induce dissolution and (2) investigated the structure-property relationship between the dissolving surface and the oxide layer. We hypothesized that solution temperature and H2O2 concentration would accelerate oxide degradation, increase corrosion kinetics and decrease experimental times. To assess this effect, we selected temperatures above (45 °C), below (24 °C), and at (37 °C) physiological levels. Then, we acquired electrochemical impedance spectra during active β dissolution, showing significant decreases in oxide polarization resistance (Rp) both over time (p = 0.000) and as temperature increased (p = 0.000). Next, using the impedance response as a guide, we quantified the extent of selective dissolution in scanning electron micrographs. As the temperature increased, the corrosion rate increased in an Arrhenius-dependent manner. Last, we identified three surface classes as the oxide properties changed: undissolved, transition and dissolved. These results indicate a concentration and temperature dependent structure-property relationship between the solution, the protective oxide film, and the substrate alloy. Additionally, we show how supraphysiological temperatures induce structurally similar dissolution to tests run at 37 °C in less experimental time. STATEMENT OF SIGNIFICANCE: Within modular taper junctions of total hip replacement systems, retrieval studies document severe corrosion including Ti-6AL-4V selective dissolution. Current pre-clinical tests and ASTM standards fail to reproduce this damage, preventing accurate screening of titanium-based biomaterials and implant designs. In this study, we induce selective dissolution using accelerated temperatures. Building off previous work, we use electrochemical impedance spectroscopy to rapidly monitor the oxide film during dissolution. We elucidate components of the dissolution mechanism, where oxide degradation precedes pit nucleation within the β phase. Using an Arrhenius approach, we relate these accelerated testing conditions to more physiologically relevant solution concentrations. In total, this study shows the importance of including adverse electrochemical events like cathodic activation and inflammatory species in pre-clinical testing.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Advanced materials and composites · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (79)
Show source-provided references
1. Titanium alloys for hip joint replacements10.1016/0267-6605(87)90015-1 ↗
2. Solar · 1979
3. In-vitro corrosion and wear of titanium alloys in the biological environment10.1016/0142-9612(96)00029-4 ↗
4. Titanium alloys in total joint replacement—a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
5. Biomaterials in orthopaedics10.1098/rsif.2008.0151 ↗
6. The use of titanium for medical applications in the USA10.1016/0921-5093(96)10243-4 ↗
7. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications10.1016/j.msec.2019.04.064 ↗
8. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
9. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application10.1016/0013-4686(95)00465-3 ↗
10. Passive layers and corrosion resistance of biomedical Ti-6Al-4V and β-Ti alloys10.3390/coatings11050487 ↗
11. Properties and biological significance of natural oxide films on titanium and its alloys
12. Titanium-tissue interface reaction and its control with surface treatment10.3389/fbioe.2019.00170 ↗
13. Corrosion between the components of modular femoral hip prostheses10.1302/0301-620X.74B4.1624507 ↗
14. In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck–stem modular taper: emergent behavior in a new mechanism of in vivo corrosion10.1002/jbm.b.31943 ↗
15. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling10.1002/jbm.820271210 ↗
16. In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants10.1002/jbm.b.31171 ↗
17. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements10.1002/jbm.b.33972 ↗
18. Current epidemiology of revision total hip arthroplasty in the United States: national Inpatient Sample 2009 to 201310.1016/j.arth.2017.02.046 ↗
19. The epidemiology of revision total hip arthroplasty in the United States10.2106/JBJS.H.00155 ↗
20. Corrosion in the human body: metallic implants in the complex body environment10.5006/2563 ↗
21. Corrosion of titanium under simulated inflammation conditions: clinical context and in vitro investigations10.1016/j.actbio.2021.10.002 ↗
22. Microstructural aspects of Ti6Al4V degradation in H2O2-containing phosphate buffered saline10.1016/j.corsci.2021.109640 ↗
23. Microstructural modification of TiAl6V4 alloy to avoid detrimental effects due to selective in vivo crevice corrosion10.3390/ma15165733 ↗
24. Electrode potential, inflammatory solution chemistry and temperature alter Ti-6Al-4V oxide film properties10.1016/j.electacta.2023.142770 ↗
25. Cathodic activation and inflammatory species are critical to simulating in vivo Ti-6Al-4V selective dissolution10.1016/j.actbio.2022.07.020 ↗
26. A synergistic effect of albumin and H2O2 accelerates corrosion of Ti6Al4V10.1016/j.actbio.2015.07.046 ↗
27. The influence of cathodic polarization and simulated inflammation on titanium electrochemistry10.1002/jbm.b.33123 ↗
28. Effect of inflammatory conditions and H2O2 on bare and coated Ti–6Al–4V surfaces: corrosion behavior, metal ion release and Ca-P formation under long-term immersion in DMEM10.1016/j.apsusc.2015.08.261 ↗
29. Hydrogen peroxide treatment on Ti–6Al–4V alloy: a promising surface modification technique for orthopaedic application10.1016/j.apsusc.2009.09.069 ↗
30. Corrosion behavior of Ti-6Al-4V with different thermomechanical treatments and microstructures10.5006/1.3452400 ↗
31. FDA · 2019
32. Comparison of ASTM F2129 and ASTM F746 for evaluating crevice corrosion10.1520/JTE20180585 ↗
33. Mechanically assisted crevice corrosion in metallic biomaterials: a review10.1080/10667857.2016.1223909 ↗
34. What do we know about taper corrosion in total hip arthroplasty?10.1016/j.arth.2014.02.014 ↗
35. Mechanisms of adverse local tissue reactions to hip implants10.3389/fbioe.2019.00176 ↗
36. Accelerating failure rate of the ASR total hip replacement10.1302/0301-620X.93B8.26040 ↗
37. The influence of HLA genotype on the development of metal hypersensitivity following joint replacement10.1038/s43856-022-00137-0 ↗
38. New materials for hip and knee joint replacement: what's hip and what's in kneed?10.1002/jor.24750 ↗
39. A survey of additive manufacturing trends for FDA-cleared medical devices10.1038/s44222-023-00109-6 ↗
40. Predicting corrosion damage in the human body using artificial intelligence: in vitro progress and future applications10.1016/j.ocl.2022.11.004 ↗
41. Microstructures and corrosion behaviors of FeCoNi and CrFeCoNi equimolar alloys10.1016/j.matchemphys.2016.11.033 ↗
42. Electrochemical behavior and surface characteristics of pure titanium during corrosion in simulated desulfurized flue gas condensates10.1149/2.1321809jes ↗
43. Temperature-dependence corrosion behavior of Ti6Al4V in the presence of HCl10.3389/fmats.2022.880702 ↗
44. Temperature dependence of crevice corrosion initiation on titanium grade-210.1149/1.1499501 ↗
45. Corrosion protection of pure titanium implant in artificial saliva by electro-polymerization of poly eugenol
46. The influence of chloride and sulphate ions on the corrosion behavior of Ti and Ti-6Al-4V alloy in oxalic acid10.1016/j.electacta.2008.12.060 ↗
47. Corrosion behaviour of Ti-6Al-4V alloy in concentrated hydrochloric and sulphuric acids10.1023/B:JACH.0000040447.26482.bd ↗
48. Corrosion behavior of Ti-6Al-4V alloy weldment in hydrochloric acid10.1002/maco.201005821 ↗
49. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer's physiological solution10.1016/j.biomaterials.2004.02.023 ↗
50. The corrosion behavior of Ti-6Al-3Nb-2Zr-1Mo alloy: effects of HCl concentration and temperature10.1016/j.jmst.2020.08.066 ↗
51. Deep neural network predicts Ti-6Al-4V dissolution state using near-field impedance spectra10.1002/adfm.202308932 ↗
52. Analysis of electrochemical impedance spectra using phase angle symmetry across log frequency10.1149/1945-7111/ab69f6 ↗
53. Additively manufactured Ti-29Nb-21Zr shows improved oxide polarization resistance versus Ti-6Al-4V in inflammatory simulating solution10.1002/jbm.a.37552 ↗
54. Effects of bovine serum albumin on the corrosion behaviour of AISI 316L, Co–28Cr–6Mo, and Ti–6Al–4V alloys in phosphate buffered saline solutions10.1016/j.corsci.2011.06.009 ↗
55. The analysis of electrode impedances complicated by the presence of a constant phase element10.1016/S0022-0728(84)80324-1 ↗
56. Analysis of electrodes displaying frequency dispersion in Mott-Schottky tests10.1149/1.2929819 ↗
57. Polarization resistance method for determination of instantaneous corrosion rates10.5006/1.3280536 ↗
58. Wear-accelerated corrosion of passive metals in tribocorrosion systems10.1149/1.1838341 ↗
59. Potential and frequency effects on fretting corrosion of Ti6Al4V and CoCrMo surfaces10.1002/jbm.a.34564 ↗
60. Fretting corrosion of CoCrMo and Ti6Al4V interfaces10.1016/j.biomaterials.2012.04.015 ↗
61. Tribo-electrochemical characterization of metallic biomaterials for total joint replacement10.1016/j.actbio.2011.09.034 ↗
62. Significance of tribocorrosion in biomedical applications: overview and current status10.1155/2009/250986 ↗
63. Influence of fretting regimes on the tribocorrosion behaviour of Ti6Al4V in 0.9wt.% sodium chloride solution10.1016/j.wear.2003.11.003 ↗
64. Third body effects and material fluxes in tribocorrosion systems involving a sliding contact10.1016/S0043-1648(03)00561-1 ↗
65. Wear-accelerated corrosion of passive metals in tribocorrosion systems10.1149/1.1838341 ↗
66. A mass balance analysis of the tribocorrosion process of titanium alloys using a single micro-asperity: voltage and solution effects on plastic deformation, oxide repassivation, and ion dissolution10.1016/j.jmbbm.2022.105531 ↗
67. Micro-asperity tribocorrosion of CoCrMo, Ti6Al4V, and 316 stainless steel in air and physiological solution: small scale reciprocal sliding of a single diamond tip10.1016/j.wear.2022.204332 ↗
68. Electrochemical behavior of additively manufactured patterned titanium alloys under simulated normal, inflammatory, and severe inflammatory conditions10.1016/j.jmrt.2023.07.113 ↗
69. Evaluation of tribocorrosion performance of Ti6Al4V alloy in simulated inflammatory and hyperglycemic microenvironments10.1016/j.wear.2023.205077 ↗
70. Corrosion resistance of β-phase titanium alloys under simulated inflammatory conditions: exploring the relevance of biocompatible alloying elements10.1016/j.corsci.2023.111271 ↗
71. The corrosion behaviour of Ti–6Al–4V, Ti–6Al–7Nb and Ti–13Nb–13Zr in protein solutions10.1016/S0142-9612(98)00217-8 ↗
72. In-vitro cell-induced corrosion by macrophages on cobalt-chromium-molybdenum alloy10.1016/j.arth.2022.01.062 ↗
73. In vitro evidence for cell-accelerated corrosion within modular junctions of total hip replacements10.1002/jor.24447 ↗
74. Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces10.1016/j.actbio.2019.10.039 ↗
75. In vitro effects of macrophages on orthopaedic implant alloys and local release of metallic alloy components10.1302/0301-620X.102B7.BJJ-2019-1556.R1 ↗
76. A crevice corrosion model for biomedical trunnion geometries and surfaces feature10.3390/ma14041005 ↗
77. M.A. Kurtz, K. Alaniz, P.W. Kurtz, A.C. Wessinger, A. Moreno-Reyes, J.L. Gilbert, Oxide degradation precedes additively manufactured Ti-6Al-4V selective dissolution: an unsupervised machine learning correlation of impedance and dissolution compared to Ti-29Nb-21Zr, J. Biomed. Mater. Res. Part A n/a(n/a).
78. Oxidative stress, inflammation, and the corrosion of metallic biomaterials: corrosion causes biology and biology causes corrosion10.1016/B978-0-12-803269-5.00003-6 ↗
79. Analysis of electrochemical impedance data: use of deep neural networks10.1002/aisy.202300085 ↗