journal article·2010-03

Comparison of two methods of fatigue testing bone cement

K.E. Tanner, Jian-Sheng Wang, Fred Kjellson, Lars Lidgren

Acta Biomaterialia· Volume 6· Issue 3
Publisher page

Abstract

Two different methods have been used to fatigue test four bone cements. Each method has been used previously, but the results have not been compared. The ISO 527-based method tests a minimum of 10 samples over a single stress range in tension only and uses Weibull analysis to calculate the median number of cycles to failure and the Weibull modulus. The ASTM F2118 test regime uses fewer specimens at various stress levels tested in fully reversed tension-compression, and generates a stress vs. number of cycles to failure (S-N) or Wöhler curve. Data from specimens with pores greater than 1mm across is rejected. The ISO 527-based test while quicker to perform, provides only tensile fatigue data, but the material tested includes pores, thus the cement is closer to cement in clinical application. The ASTM regime uses tension and compression loading and multiple stress levels, thus is closer to physiological loading, but excludes specimens with defects obviously greater than 1mm, so is less representative of cement in vivo. The fatigue lives between the cements were up to a factor 15 different for the single stress level tension only tests, while they were only a factor of 2 different in the fully reversed tension-compression testing. The ISO 527-based results are more sensitive to surface flaws, thus the differences found using ASTM F2118 are more indicative of differences in the fatigue lives. However, ISO 527-based tests are quicker, so are useful for initial screening.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone fractures and treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. A finite element study of the initiation of failure of fixation in cemented total hip components10.1002/jor.1100100116 ↗
2. Polymethylmethacrylate-induced inflammatory macrophages resorb bone10.1302/0301-620X.74B5.1527108 ↗
3. Increased osteoclastic differentiation by PMMA particle-associated macrophages – inhibitory effect by interleukin 4 and leukemia inhibitory factor10.3109/17453679608997763 ↗
4. Wear particulate species and bone loss in failed total joint arthroplasties10.1097/00003086-199707000-00016 ↗
5. Malchau H, Herberts P. Prognosis of total hip replacement and revision rate in THR: a revision risk study of 148,359 primary operations. 65th Annual meeting of the American Academy of Orthopedic Surgeons, New Orleans; 1998. Available from: www.jru.orthop.gu.se.
6. Revision total hip arthroplasty: hospital cost and reimbursement analysis10.1097/01.blo.0000072469.32680.b6 ↗
7. ASTM F2118-03 (2003) Standard test method for constant amplitude force controlled fatigue testing of acrylic bone cement materials. West Conshohocken, PA: American Society for the Testing of Materials.
8. Tensile characteristics of ten commercial acrylic bone cements10.1002/1097-4636(200009)53:5<605::AID-JBM22>3.0.CO;2-5 ↗
9. The relationship between porosity and fatigue characteristics of bone cement10.1016/S0142-9612(02)00296-X ↗
10. Damage accumulation, fatigue and creep behaviour of vacuum mixed bone cement10.1016/j.biomaterials.2005.02.009 ↗
11. On the magnitude and variability of the fatigue strength of acrylic bone cement10.1016/S0142-1123(00)00055-4 ↗
12. Relative roles of cement molecular weight and mixing method on the fatigue performance of acrylic bone cement: Simplex®P vs. Osteopal®10.1002/(SICI)1097-4636(2000)53:1<119::AID-JBM16>3.0.CO;2-N ↗
13. Influence of the radiopacifier in an acrylic bone cement on its mechanical, thermal and physical properties: barium sulfate-containing cement vs. iodine-containing cement10.1002/jbm.b.30176 ↗
14. Effect of test specimen cross-sectional shape on the in vitro fatigue life of acrylic bone cement10.1016/S0142-9612(03)00316-8 ↗
15. In vitro comparison of Refobacin–Palacos R with Refobacin® bone cement and Palacos R+G10.1080/17453670710013997 ↗
16. Inter- and intra-batch variability in the handling characteristics and viscosity of commonly used antibiotic loaded bone cements10.1080/17453670710014004 ↗
17. In vivo measurement of acetabular cement pressurisation using a simple new design of cement pressuriser10.1016/S0883-5403(99)90037-2 ↗
18. Improved acetabular pressurization gives better cement penetration – in vivo measurements during total hip arthroplasty10.1016/j.arth.2004.06.027 ↗
19. Assessment of cement introduction and pressurization techniques10.1243/095441104322807712 ↗
20. Femoral pressurization in hip arthroplasty10.1016/j.arth.2006.09.014 ↗
21. A methodology and criterion for acrylic bone cement fatigue tests10.1046/j.1460-2695.2000.00327.x ↗
22. Mechanical properties of vacuum mixed bone cement10.1002/jab.770050405 ↗
23. Fatigue strength of PMMA bone cement mixed with gentamicin and barium sulphate vs. pure PMMA10.1243/095441103762597683 ↗
24. Tensile mechanical properties of a bone cement containing non-ionic contrast media10.1023/A:1012867824140 ↗
25. Creep Behavior of hand-mixed Simplex P bone cement under cyclic tensile loading10.1002/jab.770050309 ↗
26. Creep in polytheylene and hydroxyapatite reinforced polyethylene10.1007/BF00134321 ↗
27. The initiation of failure in cemented femoral components of hip arthroplasties10.1302/0301-620X.73B4.2071634 ↗
28. Taylor D Quantitative analysis of the effect of porosity on the fatigue strength of bone cement10.1016/j.actbio.2008.08.024 ↗