The effect of heating rate on the surface chemistry of NiTi
Source abstract
Abstract
The impact of the heating rate on the Ni content at the surface of the oxide layer of biomedical NiTi is explored. Heat treatment emulating common shape-setting procedures was performed by means of conventional and inductive heating for similar annealing time and temperature, applying various heating rates from ~0.25 K s(-1) to 250 K s(-1). A glow discharge optical emission spectroscopy method was established and employed to evaluate concentration profiles of Ni, Ti and O in the near-surface region at high resolution. The Ni content at the surface of the differently treated samples varies significantly, with maximum surface Ni concentrations of ~20 at.% at the lowest and ~1.5 at.% at the highest heating rate, i.e. the total amount of Ni contained in the surface region of the oxide layer decreases by >15 times. Consequently, the heating rate is a determinant for the biomedical characteristics of NiTi, especially since Ni available at the surface of the oxide layer may affect the hemocompatibility and be released promptly after surgical application of a respective implant. Furthermore, apparently contradictory results presented in the literature reporting surface Ni concentrations of ~3 at.% to >20 at.% after heat treatment are consistently explained considering the ascertained effect of the heating rate.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Ferroelectric and Piezoelectric Materials · Advanced Sensor and Energy Harvesting Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. The utility of superelasticity in medicine10.3233/BME-1996-6404 ↗
2. Nitinol medical devices
3. An overview of nitinol medical applications10.1016/S0921-5093(99)00294-4 ↗
4. Medical uses of nitinol
5. Response of austenite finish temperature and phase transformation characteristics of thin medical-grade Ni–Ti wire to short-time annealing10.1016/j.scriptamat.2008.06.057 ↗
6. Determination of transformation properties of thin medical grade Ni–Ti wire by high-resolution bend and free recovery testing10.1007/s11665-009-9451-5 ↗
7. The influence of surface oxides on the distribution and release of nickel from Nitinol wires10.1016/j.biomaterials.2008.10.014 ↗
8. Oxidation of an NiTi alloy10.1002/sia.740150602 ↗
9. Surface oxidation of NiTi shape memory alloy10.1016/S0142-9612(02)00244-2 ↗
10. Effect of thermomechanical pre-treatment on short- and long-term Ni release from biomedical NiTi10.1016/j.actbio.2014.01.003 ↗
11. Stability of Ni in nitinol oxide surfaces10.1016/j.actbio.2010.09.009 ↗
12. Surface analyses and biocompatibility study of 500 degrees C oxidized Ni50Ti50 and Ni40Ti50Cu10 shape memory alloys10.1016/j.surfcoat.2009.01.012 ↗
13. The effect of oxide thickness on osteoblast attachment and survival on NiTi alloy10.1007/s10856-006-0082-1 ↗
14. Cyclic and isothermal oxidations of nitinol wire at moderate temperatures10.1016/j.intermet.2007.12.006 ↗
15. Oxidation of nitinol
16. Biocompatibility and hemocompatibility of surface-modified NiTi alloys10.1002/jbm.a.10549 ↗
17. The electrochemical characteristics of native Nitinol surfaces10.1016/j.biomaterials.2009.03.034 ↗
18. Quantification of the interaction between biomaterial surfaces and bacteria by 3-D modeling10.1016/j.actbio.2013.09.016 ↗
19. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility10.1002/jbm.b.30441 ↗
20. Formation of titanium oxide coatings on NiTi shape memory alloys by selective oxidation10.1016/j.msea.2007.02.151 ↗
21. In situ observation of surface oxide layers on medical grade Ni–Ti alloy during straining10.1002/jbm.a.31946 ↗
22. Mechanism of oxide layer growth during annealing of NiTi10.1002/jbm.a.34133 ↗
23. Occurrence and origin of non-martensitic acicular artifacts on NiTi10.1016/j.actamat.2010.09.026 ↗
24. Anodizing titanium for space applications10.1016/0040-6090(92)90946-9 ↗
25. Sputter crater formation in the case of microsecond pulsed glow discharge in a Grimm-type source. Comparison of direct current and radio frequency modes10.1016/j.sab.2012.06.040 ↗
26. Interference phenomena at transparent layers in glow discharge optical emission spectrometry10.1366/0003702991947658 ↗
27. Effects of short-time heat treatment and subsequent chemical surface treatment on the mechanical properties; low-cycle fatigue behavior and corrosion resistance of a Ni–Ti (50.9at.% Ni) biomedical alloy wire used for the manufacture of stents10.1016/j.msea.2010.10.043 ↗
28. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
29. Duerig T, personal communication 2013.
30. Microstructure changes during non-conventional heat treatment of thin Ni–Ti wires by pulsed electric current studied by transmission electron microscopy10.1016/j.actamat.2010.04.046 ↗