journal article·2023-09

Implantable polypyrrole bioelectrodes inducing anti-inflammatory macrophage polarization for long-term in vivo signal recording

Sanghun Lee, Sehyeon Park, Junggeon Park, Jae Young Lee

Acta Biomaterialia· Volume 168
Publisher page

Abstract

Bioelectrodes are critical components of implantable electronic devices that enable precise electrical signal transmission in close contact with living tissues. However, their in vivo performance is often compromised by inflammatory tissue reactions mainly induced by macrophages. Hence, we aimed to develop implantable bioelectrodes with high performance and high biocompatibility by actively modulating the inflammatory response of macrophages. Consequently, we fabricated heparin-doped polypyrrole electrodes (PPy/Hep) and immobilized anti-inflammatory cytokines (interleukin-4 [IL-4]) via non-covalent interactions. IL-4 immobilization did not alter the electrochemical performance of the original PPy/Hep electrodes. In vitro primary macrophage culture revealed that IL-4-immobilized PPy/Hep electrodes induced anti-inflammatory polarization of macrophages, similar to the soluble IL-4 control. In vivo subcutaneous implantation indicated that IL-4 immobilization on PPy/Hep promoted the anti-inflammatory polarization of host macrophages and significantly mitigated scarring around the implanted electrodes. In addition, high-sensitivity electrocardiogram signals were recorded from the implanted IL-4-immobilized PPy/Hep electrodes and compared to bare gold and PPy/Hep electrodes, which were maintained for up to 15 days post-implantation. This simple and effective surface modification strategy for developing immune-compatible bioelectrodes will facilitate the development of various electronic medical devices that require high sensitivities and long-term stabilities. STATEMENT OF SIGNIFICANCE: To fabricate highly immunocompatible conductive polymer-based implantable electrodes with high performance and stability in vivo, we introduced the anti-inflammatory activity to PPy/Hep electrodes by immobilizing IL-4 via non-covalent surface modification. IL-4-immobilized PPy/Hep could significantly mitigate inflammatory responses and scarring around implants by skewing macrophages to an anti-inflammatory phenotype. The IL-4-immobilized PPy/Hep electrodes could successfully record in vivo electrocardiogram signals for up to 15 days with no substantial sensitivity loss, retaining their superior sensitivity compared to bare gold and pristine PPy/Hep electrodes. Our simple and effective surface modification strategy for developing immune-compatible bioelectrodes will facilitate the development of various electronic medical devices that require high sensitivities and long-term stabilities, such as neural electrode arrays, biosensors, and cochlear electrodes.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Neuroscience and Neural Engineering · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (62)

Show source-provided references
1. Wearable and implantable devices for cardiovascular healthcare: from monitoring to therapy based on flexible and stretchable electronics10.1002/adfm.201808247 ↗
2. Materials, devices, and applications for wearable and implantable electronics10.1021/acsaelm.0c00724 ↗
3. Wearable and implantable devices for drug delivery: Applications and challenges10.1016/j.biomaterials.2022.121435 ↗
4. High-stability conducting polymer-based conformal electrodes for bio-/iono-electronics10.1016/j.mattod.2021.12.002 ↗
5. Fabrication of conducting polymer microelectrodes and microstructures for bioelectronics10.1039/D1TC01618K ↗
6. Flexible bioelectronic device fabricated by conductive polymer–based living material10.1126/sciadv.abo1458 ↗
7. Conjugated polymer for implantable electronics toward clinical application10.1002/adhm.202001916 ↗
8. Electroconductive hydrogels: Synthesis, characterization and biomedical applications10.1016/j.biomaterials.2009.12.052 ↗
9. Conductive polymers: opportunities and challenges in biomedical applications10.1021/acs.chemrev.6b00275 ↗
10. Nerve growth factor-immobilized polypyrrole: bioactive electrically conducting polymer for enhanced neurite extension10.1002/jbm.a.31047 ↗
11. Electrically controlled drug delivery from biotin-doped conductive polypyrrole10.1002/adma.200501242 ↗
12. Conductive polymers: towards a smart biomaterial for tissue engineering10.1016/j.actbio.2014.02.015 ↗
13. Macrophage polarization: an opportunity for improved outcomes in biomaterials and regenerative medicine10.1016/j.biomaterials.2012.02.034 ↗
14. Biomaterial based modulation of macrophage polarization: a review and suggested design principles10.1016/j.mattod.2015.01.019 ↗
15. Changes of postoperative impedances in cochlear implant patients: the short-term effects of modified electrode surfaces and intracochlear corticosteroids10.1097/01.mao.0000227662.88840.61 ↗
16. Macrophage and fibroblast interactions in biomaterial-mediated fibrosis10.1002/adhm.201801451 ↗
17. Macrophage-stimulated cardiac fibroblast production of IL-6 is essential for TGF β/smad activation and cardiac fibrosis induced by angiotensin II10.1371/journal.pone.0035144 ↗
18. All charged up about implanted biomaterials10.1038/nbt.2600 ↗
19. Dual roles of graphene oxide to attenuate inflammation and elicit timely polarization of macrophage phenotypes for cardiac repair10.1021/acsnano.7b09107 ↗
20. Local release of dexamethasone from macroporous scaffolds accelerates islet transplant engraftment by promotion of anti-inflammatory M2 macrophages10.1016/j.biomaterials.2016.11.004 ↗
21. A surface-engineered polyetheretherketone biomaterial implant with direct and immunoregulatory antibacterial activity against methicillin-resistant Staphylococcus aureus10.1016/j.biomaterials.2019.04.008 ↗
22. Immune modulation by design: using topography to control human monocyte attachment and macrophage differentiation10.1002/advs.201903392 ↗
23. Substrate modulus of 3D-printed scaffolds regulates the regenerative response in subcutaneous implants through the macrophage phenotype and Wnt signaling10.1016/j.biomaterials.2015.09.005 ↗
24. Macrophage polarization: different gene signatures in M1(LPS+) vs. classically and M2(LPS–) vs. alternatively activated macrophages10.3389/fimmu.2019.01084 ↗
25. Alternative activation of macrophages: mechanism and functions10.1016/j.immuni.2010.05.007 ↗
26. Hydrogel-based delivery of Il-10 improves treatment of bleomycin-induced lung fibrosis in mice10.1016/j.biomaterials.2019.02.017 ↗
27. TGFβ functionalized starPEG-heparin hydrogels modulate human dermal fibroblast growth and differentiation10.1016/j.actbio.2015.07.036 ↗
28. StarPEG-heparin hydrogels to protect and sustainably deliver IL-410.1002/adhm.201600797 ↗
29. Identification and characterization of a glycosaminoglycan binding site on interleukin-10 via molecular simulation methods10.1016/j.jmgm.2015.09.003 ↗
30. The localisation of the heparin binding sites of human and murine interleukin-12 within the carboxyterminal domain of the P40 subunit10.1016/j.cyto.2018.04.014 ↗
31. The isolation and characterization of murine macrophages
32. Bone marrow-derived macrophages (BMM): isolation and applications10.1101/pdb.prot5080 ↗
33. High-performance implantable bioelectrodes with immunocompatible topography for modulation of macrophage responses10.1021/acsnano.1c10506 ↗
34. Nitric oxide controls an inflammatory-like Ly6ChiPDCA1+ DC subset that regulates Th1 immune responses10.1189/jlb.0610329 ↗
35. Myeloid cell-derived inducible nitric oxide synthase suppresses M1 macrophage polarization10.1038/ncomms7676 ↗
36. P.C. Rodriguez, A.C. Ochoa, A.A. Al-Khami, Arginine metabolism in myeloid cells shapes innate and adaptive immunity, Front. Immunol. 8 (2017) 93, doi:10.3389/fimmu.2017.00093.10.3389/fimmu.2017.00093 ↗
37. NF-κB signaling in inflammation10.1038/sigtrans.2017.23 ↗
38. Anti-inflammatory cytokine interleukin-4 inhibits inducible nitric oxide synthase gene expression in the mouse macrophage cell line RAW264.7 through the repression of octamer-dependent transcription10.1155/2013/369693 ↗
39. Tissue-specific regulation of IL-6 production by IL-4. Differential effects of IL-4 on nuclear factor-kappa B activity in monocytes and fibroblasts10.4049/jimmunol.151.10.5603 ↗
40. Interleukin-4 suppression of tumor necrosis factor α-stimulated e-selectin gene transcription is mediated by STAT6 antagonism of NF-κB*10.1074/jbc.272.15.10212 ↗
41. IFN-γ and IL-4 differently regulate inducible NO synthase gene expression through IRF-1 modulation10.1093/intimm/12.7.977 ↗
42. Interleukin-4-mediated inhibition of nitric oxide production in interferon-γ-treated and virus-infected macrophages10.1046/j.1365-3083.1999.00495.x ↗
43. Mechanism of suppression of nitric oxide synthase expression by interleukin-4 in primary mouse macrophages10.1002/jlb.55.2.227 ↗
44. IL-4 abrogates osteoclastogenesis through STAT6-dependent inhibition of NF-κB10.1172/JCI10530 ↗
45. Interleukin-4 suppresses inflammatory cytokine gene transcription in porcine macrophages10.1002/jlb.56.4.507 ↗
46. The Foreign Body Response Demystified10.1021/acsbiomaterials.8b00252 ↗
47. Prevention of the foreign body response to implantable medical devices by inflammasome inhibition10.1073/pnas.2115857119 ↗
48. TNF-α-inhibition improves the biocompatibility of porous polyethylene implants in vivo10.1007/s13770-020-00325-w ↗
49. Understanding the mysterious M2 macrophage through activation markers and effector mechanisms10.1155/2015/816460 ↗
50. Molecular characterization of macrophage-biomaterial interactions10.1007/978-3-319-18603-0_7 ↗
51. Shifts in macrophage phenotype at the biomaterial interface via IL-4 eluting coatings are associated with improved implant integration10.1016/j.biomaterials.2016.10.019 ↗
52. Biocompatible and bioactive surface modifications for prolonged in vivo efficacy10.1021/cr2000916 ↗
53. Surface modification of nanofibrous matrices via layer-by-layer functionalized silk assembly for mitigating the foreign body reaction10.1016/j.biomaterials.2018.02.038 ↗
54. ECG diagnosis of acute ischaemia and infarction: past, present and future10.1093/qjmed/hcl025 ↗
55. Diagnosis of cardiovascular abnormalities from compressed ECG: a data mining-based approach10.1109/TITB.2010.2094197 ↗
56. Relationship between intracortical electrode design and chronic recording function10.1016/j.biomaterials.2013.07.016 ↗
57. Micro- and nanotechnology for neural electrode-tissue interfaces10.1016/j.bios.2020.112645 ↗
58. In vivo electrochemical analysis of a PEDOT/MWCNT neural electrode coating10.3390/bios5040618 ↗
59. Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays10.1016/S0925-4005(02)00448-3 ↗
60. Reduction of measurement noise in a continuous glucose monitor by coating the sensor with a zwitterionic polymer10.1038/s41551-018-0273-3 ↗
61. Long-term implant fibrosis prevention in rodents and non-human primates using crystallized drug formulations10.1038/s41563-019-0377-5 ↗
62. Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study10.1016/j.biomaterials.2017.03.019 ↗