journal article·2017-07Open access

Mechanical function near defects in an aligned nanofiber composite is preserved by inclusion of disorganized layers: Insight into meniscus structure and function

Sonia Bansal, Sai Mandalapu, Céline Aeppli, Feini Qu, Spencer E. Szczesny, Robert L. Mauck, Miltiadis H. Zgonis

Acta Biomaterialia· Volume 56

Abstract

The meniscus is comprised of circumferentially aligned fibers that resist the tensile forces within the meniscus (i.e., hoop stress) that develop during loading of the knee. Although these circumferential fibers are severed by radial meniscal tears, tibial contact stresses do not increase until the tear reaches ∼90% of the meniscus width, suggesting that the severed circumferential fibers still bear load and maintain the mechanical functionality of the meniscus. Recent data demonstrates that the interfibrillar matrix can transfer strain energy to disconnected fibrils in tendon fascicles. In the meniscus, interdigitating radial tie fibers, which function to stabilize and bind the circumferential fibers together, are hypothesized to function in a similar manner by transmitting load to severed circumferential fibers near a radial tear. To test this hypothesis, we developed an engineered fibrous analog of the knee meniscus using poly(ε-caprolactone) to create aligned scaffolds with variable amounts of non-aligned elements embedded within the scaffold. We show that the tensile properties of these scaffolds are a function of the ratio of aligned to non-aligned elements, and change in a predictable fashion following a simple mixture model. When measuring the loss of mechanical function in scaffolds with a radial tear, compared to intact scaffolds, the decrease in apparent linear modulus was reduced in scaffolds containing non-aligned layers compared to purely aligned scaffolds. Increased strains in areas adjacent to the defect were also noted in composite scaffolds. These findings indicate that non-aligned (disorganized) elements interspersed within an aligned network can improve overall mechanical function by promoting strain transfer to nearby disconnected fibers. This finding supports the notion that radial tie fibers may similarly promote tear tolerance in the knee meniscus, and will direct changes in clinical practice and provide guidance for tissue engineering strategies. Statement of significance The meniscus is a complex fibrous tissue, whose architecture includes radial tie fibers that run perpendicular to and interdigitate with the predominant circumferential fibers. We hypothesized that these radial elements function to preserve mechanical function in the context of interruption of circumferential bundles, as would be the case in a meniscal tear. To test this hypothesis, we developed a biomaterial analog containing disorganized layers enmeshed regularly throughout an otherwise aligned network. Using this material formulation, we showed that strain transmission is improved in the vicinity of defects when disorganized fiber layers were present. This supports the idea that radial elements within the meniscus improve function near a tear, and will guide future clinical interventions and the development of engineered replacements.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Knee injuries and reconstruction techniques · Tendon Structure and Treatment · Polymer Surface Interaction Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Spatial organization of types I and II collagen in the canine meniscus10.1016/j.orthres.2004.06.016 ↗
2. Meniscus structure in human, sheep, and rabbit for animal models of meniscus repair10.1002/jor.20869 ↗
3. Radial tie fibers influence the tensile properties of the bovine medial meniscus10.1002/jor.1100120205 ↗
4. The knee meniscus: structure-function, pathophysiology, current repair techniques, and prospects for regeneration10.1016/j.biomaterials.2011.06.037 ↗
5. Tie-fibre structure and organization in the knee menisci10.1111/joa.12170 ↗
6. New understanding of the complex structure of knee menisci: implications for injury risk and repair potential for athletes10.1111/j.1600-0838.2009.01073.x ↗
7. The strength of the menisci of the knee as it relates to their fine structure10.1302/0301-620X.52B3.564 ↗
8. Successful total meniscus reconstruction using a novel fiber-reinforced scaffold: a 16- and 32-week study in an ovine model10.1177/0363546515595065 ↗
9. Treatment of meniscal tears: an evidence based approach10.5312/wjo.v5.i3.233 ↗
10. Meniscectomy as a risk factor for knee osteoarthritis: a systematic review10.1093/bmb/ldq043 ↗
11. Dynamic contact mechanics of the medial meniscus as a function of radial tear, repair, and partial meniscectomy10.2106/JBJS.I.00539 ↗
12. Preliminary study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus10.1016/S0142-9612(02)00378-2 ↗
13. A two year in vivo study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus10.1016/j.biomaterials.2004.08.028 ↗
14. Tissue engineering for total meniscal substitution: animal study in sheep model—results at 12 months10.1089/ten.tea.2011.0572 ↗
15. Chondroprotective effects of a polycarbonate-urethane meniscal implant: histopathological results in a sheep model10.1007/s00167-010-1210-5 ↗
16. PLDLA/PCL-T scaffold for meniscus tissue engineering10.1089/biores.2012.0293 ↗
17. Engineering controllable anisotropy in electrospun biodegradable nanofibrous scaffolds for musculoskeletal tissue engineering10.1016/j.jbiomech.2006.09.004 ↗
18. Sacrificial nanofibrous composites provide instruction without impediment and enable functional tissue formation10.1073/pnas.1206962109 ↗
19. Organized nanofibrous scaffolds that mimic the macroscopic and microscopic architecture of the knee meniscus10.1016/j.actbio.2012.10.018 ↗
20. Nanofibrous biologic laminates replicate the form and function of the annulus fibrosus10.1038/nmat2558 ↗
21. Homologous structure-function relationships between native fibrocartilage and tissue engineered from MSC-seeded nanofibrous scaffolds10.1016/j.biomaterials.2010.09.015 ↗
22. The effect of nanofiber alignment on the maturation of engineered meniscus constructs10.1016/j.biomaterials.2007.01.004 ↗
23. FibrilTool, an ImageJ plug-in to quantify fibrillar structures in raw microscopy images10.1038/nprot.2014.024 ↗
24. Favata · 2006
25. Fabrication and modeling of dynamic multipolymer nanofibrous scaffolds10.1115/1.3192140 ↗
26. A continuous method to compute model parameters for soft biological materials10.1115/1.4004412 ↗
27. Elasticity of soft tissues in simple elongation10.1152/ajplegacy.1967.213.6.1532 ↗
28. The intrinsic tensile behaviour of the matrix of bovine articular cartilage and its variations with age10.2106/00004623-198062070-00007 ↗
29. Biomechanical and structural response of healing Achilles tendon to fatigue loading following acute injury10.1016/j.jbiomech.2013.10.054 ↗
30. Localization of viscous behavior and shear energy dissipation in articular cartilage under dynamic shear loading10.1115/1.4007454 ↗
31. Contribution of glycosaminoglycans to viscoelastic tensile behavior of human ligament10.1152/japplphysiol.90748.2008 ↗
32. Engineering on the straight and narrow: the mechanics of nanofibrous assemblies for fiber-reinforced tissue regeneration10.1089/ten.teb.2008.0652 ↗
33. Meniscus mechanics and mechanobiology10.1016/j.jbiomech.2015.03.020 ↗
34. Macro- to microscale strain transfer in fibrous tissues is heterogeneous and tissue-specific10.1016/j.bpj.2013.06.023 ↗
35. Mechanical design criteria for intervertebral disc10.1016/j.jbiomech.2009.12.001 ↗
36. The role of mechanobiology in tendon healing10.1016/j.jse.2011.11.002 ↗
37. Interfibrillar shear stress is the loading mechanism of collagen fibrils in tendon10.1016/j.actbio.2014.01.032 ↗
38. Quantification of interfibrillar shear stress in aligned soft collagenous tissues via notch tension testing10.1038/srep14649 ↗
39. Incorporating plasticity of the interfibrillar matrix in shear lag models is necessary to replicate the multiscale mechanics of tendon fascicles10.1016/j.jmbbm.2014.09.005 ↗
40. In vitro hemocompatibility and cytocompatibility of a three-layered vascular scaffold fabricated by sequential electrospinning of PCL, collagen, and PLLA nanofibers
41. Three-layered PCL grafts promoted vascular regeneration in a rabbit carotid artery model10.1002/mabi.201500355 ↗
42. In vivo performance of an acellular disc-like angle ply structure (DAPS) for total disc replacement in a small animal model