journal article·2011-08

Soft tissue response to titanium dioxide nanotube modified implants

Garrett C. Smith, Lisa Chamberlain, Linda Faxius, Gary W. Johnston, Sungho Jin, Lars M. Bjursten

Acta Biomaterialia· Volume 7· Issue 8
Publisher page

Abstract

Titanium is widely used clinically, yet little is known regarding the effects of modifying its three-dimensional surface geometry at the nanoscale level. In this project we have explored the in vivo response in terms of nitric oxide scavenging and fibrotic capsule formation to nano-modified titanium implant surfaces. We compared titanium dioxide (TiO(2)) nanotubes with 100 nm diameters fabricated by electrochemical anodization with TiO(2) control surfaces. Significantly lower nitric oxide was observed for the nanostructured surface in solution, suggesting that nanotubes break down nitric oxide. To evaluate the soft tissue response in vivo TiO(2) nanotube and TiO(2) control implants were placed in the rat abdominal wall for 1 and 6 weeks. A reduced fibrotic capsule thickness was observed for the nanotube surfaces for both time points. Significantly lower nitric oxide activity, measured as the presence of nitrotyrosine (P<0.05), was observed on the nanotube surface after 1 week, indicating that the reactive nitrogen species interaction is of importance. The differences observed between the titanium surfaces may be due to the catalytic properties of TiO(2), which are increased by the nanotube structure. These findings may be significant for the interaction between titanium implants in soft tissue as well as bone tissue and provide a mechanism by which to improve future clinical implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Electrospun Nanofibers in Biomedical Applications · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Quantifying the soft tissue response to implanted materials10.1016/0142-9612(95)92113-K ↗
2. Interaction between hydrogen peroxide and titanium: a possible role in the biocompatibility of titanium10.1016/0142-9612(89)90043-4 ↗
3. Of microbes, macrophages and nitric oxide
4. Nitric oxide, oxidants, and protein tyrosine nitration10.1073/pnas.0307446101 ↗
5. The role of titanium surface topography on J774A.1 macrophage inflammatory cytokines and nitric oxide production10.1016/j.biomaterials.2006.05.002 ↗
6. Charge injection capacity of TiN electrodes for an extended voltage range10.1109/IEMBS.2006.260088 ↗
7. Protein adsorption on materials for recording sites on implantable microelectrodes10.1007/s10856-007-3110-x ↗
8. An amperometric glucose biosensor constructed by immobilizing glucose oxidase on titanium-containing mesoporous composite material of no. 41 modified screen-printed electrodes10.1016/j.aca.2007.03.063 ↗
9. On the mechanisms of biocompatibility10.1016/j.biomaterials.2008.04.023 ↗
10. Osseointegration of anodized titanium implants under different current voltages: a rabbit study10.1111/j.1365-2842.2006.01688.x ↗
11. Inhibition of inflammatory species by titanium surfaces10.1097/00003086-200003000-00031 ↗
12. Reactive oxygen species inhibited by titanium oxide coatings10.1002/jbm.a.10001 ↗
13. Significantly accelerated osteoblast cell growth on aligned TiO2 nanotubes10.1002/jbm.a.30722 ↗
14. Stem cell fate dictated solely by altered nanotube dimension10.1073/pnas.0813200106 ↗
15. Growth of nano-scale hydroxyapatite using chemically treated titanium oxide nanotubes10.1016/j.biomaterials.2005.01.048 ↗
16. Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface10.1016/j.actbio.2009.05.008 ↗
17. Implants in the abdominal wall of the rat
18. Analysis of the inflammatory response to titanium and PTFE implants in soft tissue by macrophage phenotype quantification10.1023/A:1013239731256 ↗
19. Titanium dioxide nanotubes enhance bone bonding in vivo10.1002/jbm.a.32463 ↗
20. A new and evolving paradigm for biocompatibility10.1002/term.4 ↗
21. Bone bonding at natural and biomaterial surfaces10.1016/j.biomaterials.2007.07.049 ↗
22. How surface topography relates to materials’ properties10.1126/science.1074955 ↗
23. Interactions between human whole blood and modified TiO2-surfaces: influence of surface topography and oxide thickness on leukocyte adhesion and activation10.1016/S0142-9612(00)00382-3 ↗
24. Anti-inflammatory effects of a titanium–peroxy gel: role of oxygen metabolites and apoptosis10.1002/jbm.a.20078 ↗
25. Evaluation of the effect of three surface treatments on the biocompatibility of 316L stainless steel using human differentiated cells10.1016/0142-9612(96)82723-2 ↗
26. Hydrophobic nanopillars initiate mesenchymal stem cell aggregation and osteo-differentiation10.1016/j.actbio.2010.09.022 ↗
27. Reduced responses of macrophages on nanometer surface features of altered alumina crystalline phases10.1016/j.actbio.2009.01.031 ↗
28. Microstructure and formation mechanism of titanium dioxide nanotubes10.1016/S0009-2614(02)01502-6 ↗
29. In vivo expression of osteogenic markers and bone mineral density at the surface of fluoride-modified titanium implants10.1016/j.biomaterials.2008.06.001 ↗
30. Controlled electro-implementation of fluoride in titanium implant surfaces enhances cortical bone formation and mineralization10.1016/j.actbio.2009.09.014 ↗
31. Models for the histologic study of the skin interface with percutaneous biomaterials10.1088/1748-6041/3/3/034006 ↗
32. Soft tissue reactions evoked by implanted gallium phosphide10.1016/j.biomaterials.2008.08.028 ↗
33. Anti-inflammatory properties of micropatterned titanium coatings10.1002/jbm.a.30642 ↗
34. Direct bone anchorage of oral implants: clinical and experimental considerations of the concept of osseointegration